ELN-60 Series
60W Single Output Switching Power Supply
Application:
Features
Universal AC input / Full range
Protections: Short circuit / Over current / Over voltage
Cooling by free air convection
Built-in constant current limiting circuit with adjustable OCP level
Optional dimming function : 1~10VDC (D type) or PWM (P type) controlled
Class power unit, no FG
Class 2 power unit
Fully isolated plastic case
100% full load burn-in test
2 years warranty
ELN-60 series
MODEL | ELN-60-9 | ELN-60-12 | ELN-60-15 | |
---|---|---|---|---|
OUTPUT | DC VOLTAGE | 9V | 12V | 15V |
LED OPERATION VOLTAGE | 3 ~ 9V | 6 ~ 12V | 7.5 ~ 15V | |
RATED CURRENT | 5A | 5A | 4A | |
CURRENT RANGE | 0 ~ 5A | 0 ~ 5A | 0 ~ 4A | |
RATED POWER | 45W | 60W | 60W | |
RIPPLE & NOISE (max.) Note.2 | 120mVp-p | 120mVp-p | 150mVp-p | |
VOLTAGE ADJ. RANGE(Can be adjusted by internal potentiometer SVR1) | 8.7 ~ 10.5V | 10.8 ~ 13.2V | 13.5 ~ 16.5V | |
CURRENT ADJ. RANGE | -25% ~ 3%. Can be adjusted by internal potentiometer SVR2 | -25% ~ 3%. Can be adjusted by internal potentiometer SVR2 | -25% ~ 3%. Can be adjusted by internal potentiometer SVR2 | |
VOLTAGE TOLERANCE | ±5.0% | ±5.0% | ±5.0% | |
LINE REGULATION | ±1.0% | ±1.0% | ±1.0% | |
LOAD REGULATION | ±2.0% | ±2.0% | ±2.0% | |
SETUP, RISE TIME | 500ms, 30ms / 230VAC 1500ms, 30ms / 115VAC at full load | 500ms, 30ms / 230VAC 1500ms, 30ms / 115VAC at full load | 500ms, 30ms / 230VAC 1500ms, 30ms / 115VAC at full load | |
HOLD UP TIME (Typ.) | 50ms/230VAC 16ms/115VAC at full load | 50ms/230VAC 16ms/115VAC at full load | 50ms/230VAC 16ms/115VAC at full load | |
INPUT | VOLTAGE RANGE | 90 ~ 264VAC 127 ~ 370VDC | 90 ~ 264VAC 127 ~ 370VDC | 90 ~ 264VAC 127 ~ 370VDC |
FREQUENCY RANGE | 47 ~ 63Hz | 47 ~ 63Hz | 47 ~ 63Hz | |
EFFICIENCY (Typ.) | 82% | 85% | 86% | |
AC CURRENT | 1.2A/115VAC 0.7A/230VAC | 1.2A/115VAC 0.7A/230VAC | 1.2A/115VAC 0.7A/230VAC | |
INRUSH CURRENT(Typ.) | COLD START 60A(twidth=600 s measured at 50% Ipeak) at 230VAC | COLD START 60A(twidth=600 s measured at 50% Ipeak) at 230VAC | COLD START 60A(twidth=600 s measured at 50% Ipeak) at 230VAC | |
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 3 units (circuit breaker of type B) / 5 units (circuit breaker of type C) at 230VAC | 3 units (circuit breaker of type B) / 5 units (circuit breaker of type C) at 230VAC | 3 units (circuit breaker of type B) / 5 units (circuit breaker of type C) at 230VAC | |
LEAKAGE CURRENT | 0.25mA/ 240VAC | 0.25mA/ 240VAC | 0.25mA/ 240VAC | |
Specs Sheet |
ELN-60 series
MODEL | ELN-60-24 | ELN-60-27 | ELN-60-48 | |
---|---|---|---|---|
OUTPUT | DC VOLTAGE | 24V | 27V | 48V |
LED OPERATION VOLTAGE | 12 ~ 24V | 13.5 ~ 27V | 24 ~ 48V | |
RATED CURRENT | 2.5A | 2.3A | 1.3A | |
CURRENT RANGE | 0 ~ 2.5A | 0 ~ 2.3A | 0 ~ 1.3A | |
RATED POWER | 60W | 62.1W | 62.5W | |
RIPPLE & NOISE (max.) Note.2 | 150mVp-p | 200mVp-p | 250mVp-p | |
VOLTAGE ADJ. RANGE(Can be adjusted by internal potentiometer SVR1) | 21.6 ~ 26.4V | 24.3 ~ 29.7V | 43.2 ~ 52.8V | |
CURRENT ADJ. RANGE | -25% ~ 3%. Can be adjusted by internal potentiometer SVR2 | -25% ~ 3%. Can be adjusted by internal potentiometer SVR2 | -25% ~ 3%. Can be adjusted by internal potentiometer SVR2 | |
VOLTAGE TOLERANCE | ±5.0% | ±5.0% | ±5.0% | |
LINE REGULATION | ±1.0% | ±1.0% | ±1.0% | |
LOAD REGULATION | ±2.0% | ±2.0% | ±2.0% | |
SETUP, RISE TIME | 500ms, 30ms / 230VAC 1500ms, 30ms / 115VAC at full load | 500ms, 30ms / 230VAC 1500ms, 30ms / 115VAC at full load | 500ms, 30ms / 230VAC 1500ms, 30ms / 115VAC at full load | |
HOLD UP TIME (Typ.) | 50ms/230VAC 16ms/115VAC at full load | 50ms/230VAC 16ms/115VAC at full load | 50ms/230VAC 16ms/115VAC at full load | |
INPUT | VOLTAGE RANGE | 90 ~ 264VAC 127 ~ 370VDC | 90 ~ 264VAC 127 ~ 370VDC | 90 ~ 264VAC 127 ~ 370VDC |
FREQUENCY RANGE | 47 ~ 63Hz | 47 ~ 63Hz | 47 ~ 63Hz | |
EFFICIENCY (Typ.) | 87% | 87% | 88% | |
AC CURRENT | 1.2A/115VAC 0.7A/230VAC | 1.2A/115VAC 0.7A/230VAC | 1.2A/115VAC 0.7A/230VAC | |
INRUSH CURRENT(Typ.) | COLD START 60A(twidth=600 s measured at 50% Ipeak) at 230VAC | COLD START 60A(twidth=600 s measured at 50% Ipeak) at 230VAC | COLD START 60A(twidth=600 s measured at 50% Ipeak) at 230VAC | |
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 3 units (circuit breaker of type B) / 5 units (circuit breaker of type C) at 230VAC | 3 units (circuit breaker of type B) / 5 units (circuit breaker of type C) at 230VAC | 3 units (circuit breaker of type B) / 5 units (circuit breaker of type C) at 230VAC | |
LEAKAGE CURRENT | 0.25mA/ 240VAC | 0.25mA/ 240VAC | 0.25mA/ 240VAC | |
Specs Sheet |