PLP-20 Series
20W Single Outlet LED Power Supply

NRCS LOA APPROVED
|
|
Application:
Features
* Universal AC input / Fullrange(up to 277VAC)
* Protections:Short circuit/Over current/Over voltage/Over temperature
* Cooling by free air convection
* Built-in constant current limiting circuit with adjustable OCP level
* Built-in active PFC function
* Small and compact size
* 100% full load burn-in test
* High reliability, low cost
* Suitable for built-in applications of LED lighting
* 2 years warranty
PLP-20 series
| MODEL | PLP-20-12 | PLP-20-18 | |
|---|---|---|---|
| OUTPUT | DC VOLTAGE | 12V | 18V |
| CONSTANT CURRENT REGION | 9 ~ 12V | 13.5 ~ 18V | |
| RATED CURRENT | 1.6A | 1.1A | |
| CURRENT RANGE | 0 ~ 1.6A | 0 ~ 1.1A | |
| CURRENTADJ. RANGE | 75% ~ 100% | 75% ~ 100% | |
| RATED POWER | 19.2W | 19.8W | |
| RIPPLE & NOISE (max.) | 2.5Vp-p | 3.0Vp-p | |
| VOLTAGE TOLERANCE | ±10% | ±10% | |
| LINE REGULATION | ±3.0% | ±3.0% | |
| LOAD REGULATION | ±10% | ±10% | |
| SETUP, RISE TIME | 500ms / 230VAC 2000ms / 115VAC at full load | 500ms / 230VAC 2000ms / 115VAC at full load | |
| INPUT | VOLTAGE RANGE | 90 ~ 277VAC 127~392VDC | 90 ~ 277VAC 127~392VDC |
| FREQUENCY RANGE | 47 ~ 63Hz | 47 ~ 63Hz | |
| POWER FACTOR | PF>=0.95/115VAC,PF>0.9/230VAC,PF>0.9/277VAC at full load | PF>=0.95/115VAC,PF>0.9/230VAC,PF>0.9/277VAC at full load | |
| TOTALHARMONIC DISTORTION | THD< 20% when output loading>=75% at 115VAC/230VAC input and output loading>=75% at 277VAC input | THD< 20% when output loading>=75% at 115VAC/230VAC input and output loading>=75% at 277VAC input | |
| EFFICIENCY (Typ.) | 80% | 81% | |
| AC CURRENT | 0.4A/115VAC 0.2A/230VAC 0.15A/277VAC | 0.4A/115VAC 0.2A/230VAC 0.15A/277VAC | |
| INRUSH CURRENT(Typ.) | COLD START 25A(twidth=60 s measured at 50% Ipeak) at 230VAC | COLD START 25A(twidth=60 s measured at 50% Ipeak) at 230VAC | |
| MAX. No. of PSUs on 16A CIRCUIT BREAKER | 92 units (circuit breaker of type B) / 98 units (circuit breaker of type C) at 230VAC | 92 units (circuit breaker of type B) / 98 units (circuit breaker of type C) at 230VAC | |
| LEAKAGE CURRENT | 0.5mA/ 240VAC | 0.5mA/ 240VAC | |
| Specs Sheet |
PLP-20 series
| MODEL | PLP-20-36 | PLP-20-48 | |
|---|---|---|---|
| OUTPUT | DC VOLTAGE | 36V | 48V |
| CONSTANT CURRENT REGION | 27 ~ 36V | 36 ~ 48V | |
| RATED CURRENT | 0.55A | 0.42A | |
| CURRENT RANGE | 0 ~ 0.55A | 0 ~ 0.42A | |
| CURRENTADJ. RANGE | 75% ~ 100% | 75% ~ 100% | |
| RATED POWER | 19.8W | 20.2W | |
| RIPPLE & NOISE (max.) | 3.0Vp-p | 3.8Vp-p | |
| VOLTAGE TOLERANCE | ±10% | ±10% | |
| LINE REGULATION | ±3.0% | ±3.0% | |
| LOAD REGULATION | ±10% | ±10% | |
| SETUP, RISE TIME | 500ms / 230VAC 2000ms / 115VAC at full load | 500ms / 230VAC 2000ms / 115VAC at full load | |
| INPUT | VOLTAGE RANGE | 90 ~ 277VAC 127~392VDC | 90 ~ 277VAC 127~392VDC |
| FREQUENCY RANGE | 47 ~ 63Hz | 47 ~ 63Hz | |
| POWER FACTOR | PF>=0.95/115VAC,PF>0.9/230VAC,PF>0.9/277VAC at full load | PF>=0.95/115VAC,PF>0.9/230VAC,PF>0.9/277VAC at full load | |
| TOTALHARMONIC DISTORTION | THD< 20% when output loading>=75% at 115VAC/230VAC input and output loading>=75% at 277VAC input | THD< 20% when output loading>=75% at 115VAC/230VAC input and output loading>=75% at 277VAC input | |
| EFFICIENCY (Typ.) | 83% | 83.5% | |
| AC CURRENT | 0.4A/115VAC 0.2A/230VAC 0.15A/277VAC | 0.4A/115VAC 0.2A/230VAC 0.15A/277VAC | |
| INRUSH CURRENT(Typ.) | COLD START 25A(twidth=60 s measured at 50% Ipeak) at 230VAC | COLD START 25A(twidth=60 s measured at 50% Ipeak) at 230VAC | |
| MAX. No. of PSUs on 16A CIRCUIT BREAKER | 92 units (circuit breaker of type B) / 98 units (circuit breaker of type C) at 230VAC | 92 units (circuit breaker of type B) / 98 units (circuit breaker of type C) at 230VAC | |
| LEAKAGE CURRENT | 0.5mA/ 240VAC | 0.5mA/ 240VAC | |
| Specs Sheet |