APC-12E series
12W Single Output Switching Power Supply
Application:
Features
Constant voltage design
Class II power unit, no FG
Fully isolated plastic case
Cooling by free air size
No load power consumption <0.5W
100% full load burn-in test
Low cost, high reliability
2 years warranty
Pass LPS
IP 42 design
APC-12E series
MODEL | APC-12-350 | APC-12-700 | |
---|---|---|---|
OUTPUT | RATED CURRENT | 350mA | 700mA |
DC VOLTAGE | 9~36V | 9~18V | |
RATED POWER | 12.6W | 12.6W | |
RIPPLE & NOISE (max.) | 300mVp-p | 250mVp-p | |
VOLTAGE TOLERANCE | ±5.0% | ±5.0% | |
CURRENT ACCURACY | ±8.0% | ±8.0% | |
LINE REGULATION | ±1.0% | ±1.0% | |
LOAD REGULATION | ±3.0% | ±3.0% | |
SETUP, RISE TIME | 3000ms, 180ms / 230VAC 3000ms, 150ms / 115VAC at full load | 3000ms, 180ms / 230VAC 3000ms, 150ms / 115VAC at full load | |
HOLD UP TIME (Typ.) | 20ms/230VAC,15ms/115VAC at full load | 20ms/230VAC,15ms/115VAC at full load | |
INPUT | VOLTAGE RANGE | 180 ~ 264VAC 254 ~ 370VDC | 180 ~ 264VAC 254 ~ 370VDC |
FREQUENCY RANGE | 47 ~ 63Hz | 47 ~ 63Hz | |
EFFICIENCY (Typ.) | 81% | 79% | |
AC CURRENT | 0.2A/230VAC;0.35A/115VAC | 0.2A/230VAC;0.35A/115VAC | |
INRUSH CURRENT(Typ.) | COLD START 70A(twidth=120 s measured at 50% Ipeak) at 230VAC | COLD START 70A(twidth=120 s measured at 50% Ipeak) at 230VAC | |
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 17 units (circuit breaker of type B) / 29 units (circuit breaker of type C) at 230VAC | 17 units (circuit breaker of type B) / 29 units (circuit breaker of type C) at 230VAC | |
LEAKAGE CURRENT | 0.25mA / 240VAC | 0.25mA / 240VAC | |
Specs Sheet |