HLG-80H series
80W Constant Voltage + Constant Current LED Driver
buy online NOW
NRCS LOA APPROVED
|
Application:
Features
Constant Voltage + Constant current mode ouput
Metal housing design with class 1 design
Built-in active PFC function
Class 2 power unit
IP67 / IP65 design for indoor or outdoor installations
Function options: output adjustable via potentiometer
3 in 1 dimming (dim-to-off)
Timer Dimming
Typical lifetime > 62000 hours
7 year warranty
HLG-80H series
MODEL | HLG-80H-12 | HLG-80H-15 | HLG-80H-20 | |
---|---|---|---|---|
OUTPUT | DC VOLTAGE | 12V | 15V | 20V |
CONSTANT CURRENT REGION | 7.2 ~12V | 9 ~ 15V | 12 ~ 20V | |
RATED CURRENT | 5A | 5A | 4A | |
RATED POWER | 60W | 75W | 80W | |
RIPPLE & NOISE (max.) | 150mVp-p | 150mVp-p | 150mVp-p | |
VOLTAGE ADJ. RANGE - Adjustable forA-Type only (via built-in potentiometer) | 10.8 ~ 13.5V | 13.5 ~ 17V | 17 ~ 22V | |
CURRENT ADJ. RANGE - Adjustable forA-Type only (via built-in potentiometer) | 3 ~ 5A | 3 ~ 5A | 2.4 ~ 4A | |
VOLTAGE TOLERANCE | ±2.5% | ±2.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±2.0% | ±1.5% | ±1.0% | |
SET UP TIME | 1200ms,200ms/115VAC 500ms,200ms/230VAC | 1200ms,200ms/115VAC 500ms,200ms/230VAC | 1200ms,200ms/115VAC 500ms,200ms/230VAC | |
HOLD UP TIME (Typ.) | 16ms at full load 230VAC /115VAC | 16ms at full load 230VAC /115VAC | 16ms at full load 230VAC /115VAC | |
INPUT | VOLTAGE RANGE | 90 ~ 305VAC 127 ~ 431VDC | 90 ~ 305VAC 127 ~ 431VDC | 90 ~ 305VAC 127 ~ 431VDC |
FREQUENCY RANGE | 47 ~ 63Hz | 47 ~ 63Hz | 47 ~ 63Hz | |
POWER FACTOR (Typ.) | PF>=0.96/115VAC, PF>=0.96/230VAC, PF>=0.94/277VAC @ full load | PF>=0.96/115VAC, PF>=0.96/230VAC, PF>=0.94/277VAC @ full load | PF>=0.96/115VAC, PF>=0.96/230VAC, PF>=0.94/277VAC @ full load | |
TOTAL HARMONIC DISTORTION | THD< 20% (@>=load 60% / 115VAC,230VAC; @ load>=75% / 277VAC) | THD< 20% (@>=load 60% / 115VAC,230VAC; @ load>=75% / 277VAC) | THD< 20% (@>=load 60% / 115VAC,230VAC; @ load>=75% / 277VAC) | |
EFFICIENCY (Typ.) | 88% | 89% | 90% | |
AC CURRENT (Typ.) | 0.85A/ 115VAC 0.425A/ 230VAC 0.4A/ 277VAC | 0.85A/ 115VAC 0.425A/ 230VAC 0.4A/ 277VAC | 0.85A/ 115VAC 0.425A/ 230VAC 0.4A/ 277VAC | |
INRUSH CURRENT(Typ.) | COLD START 70A(t =485 s measured at 50% I ) at 230VAC width peak ; Per NEMA410 | COLD START 70A(t =485 s measured at 50% I ) at 230VAC width peak ; Per NEMA410 | COLD START 70A(t =485 s measured at 50% I ) at 230VAC width peak ; Per NEMA410 | |
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 3 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC | 3 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC | 3 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC | |
LEAKAGE CURRENT | <0.75mA/ 277VAC | <0.75mA/ 277VAC | <0.75mA/ 277VAC | |
Specs Sheet |
HLG-80H series
MODEL | HLG-80H-24 | HLG-80H-30 | HLG-80H-36 | |
---|---|---|---|---|
OUTPUT | DC VOLTAGE | 24V | 30V | 36V |
CONSTANT CURRENT REGION | 14.4 ~ 24V | 18 ~ 30V | 21.6 ~ 36V | |
RATED CURRENT | 3.4A | 2.7A | 2.3A | |
RATED POWER | 81.6W | 81W | 82.8W | |
RIPPLE & NOISE (max.) | 150mVp-p | 200mVp-p | 200mVp-p | |
VOLTAGE ADJ. RANGE - Adjustable forA-Type only (via built-in potentiometer) | 22 ~ 27V | 27 ~ 33V | 33 ~ 40V | |
CURRENT ADJ. RANGE - Adjustable forA-Type only (via built-in potentiometer) | 2.04 ~ 3.4A | 1.62 ~ 2.7A | 1.38 ~ 2.3A | |
VOLTAGE TOLERANCE | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±0.5% | ±0.5% | ±0.5% | |
SET UP TIME | 1200ms,200ms/115VAC 500ms,200ms/230VAC | 1200ms,200ms/115VAC 500ms,200ms/230VAC | 1200ms,200ms/115VAC 500ms,200ms/230VAC | |
HOLD UP TIME (Typ.) | 16ms at full load 230VAC /115VAC | 16ms at full load 230VAC /115VAC | 16ms at full load 230VAC /115VAC | |
INPUT | VOLTAGE RANGE | 90 ~ 305VAC 127 ~ 431VDC | 90 ~ 305VAC 127 ~ 431VDC | 90 ~ 305VAC 127 ~ 431VDC |
FREQUENCY RANGE | 47 ~ 63Hz | 47 ~ 63Hz | 47 ~ 63Hz | |
POWER FACTOR (Typ.) | PF>=0.96/115VAC, PF>=0.96/230VAC, PF>=0.94/277VAC @ full load | PF>=0.96/115VAC, PF>=0.96/230VAC, PF>=0.94/277VAC @ full load | PF>=0.96/115VAC, PF>=0.96/230VAC, PF>=0.94/277VAC @ full load | |
TOTAL HARMONIC DISTORTION | THD< 20% (@>=load 60% / 115VAC,230VAC; @ load>=75% / 277VAC) | THD< 20% (@>=load 60% / 115VAC,230VAC; @ load>=75% / 277VAC) | THD< 20% (@>=load 60% / 115VAC,230VAC; @ load>=75% / 277VAC) | |
EFFICIENCY (Typ.) | 90.5% | 91% | 91% | |
AC CURRENT (Typ.) | 0.85A/ 115VAC 0.425A/ 230VAC 0.4A/ 277VAC | 0.85A/ 115VAC 0.425A/ 230VAC 0.4A/ 277VAC | 0.85A/ 115VAC 0.425A/ 230VAC 0.4A/ 277VAC | |
INRUSH CURRENT(Typ.) | COLD START 70A(t =485 s measured at 50% I ) at 230VAC width peak ; Per NEMA410 | COLD START 70A(t =485 s measured at 50% I ) at 230VAC width peak ; Per NEMA410 | COLD START 70A(t =485 s measured at 50% I ) at 230VAC width peak ; Per NEMA410 | |
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 3 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC | 3 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC | 3 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC | |
LEAKAGE CURRENT | <0.75mA/ 277VAC | <0.75mA/ 277VAC | <0.75mA/ 277VAC | |
Specs Sheet |
HLG-80H series
MODEL | HLG-80H-42 | HLG-80H-48 | HLG-80H-54 | |
---|---|---|---|---|
OUTPUT | DC VOLTAGE | 42V | 48V | 54V |
CONSTANT CURRENT REGION | 25.2 ~ 42V | 28.8 ~ 48V | 32.4 ~ 54V | |
RATED CURRENT | 1.95A | 1.7A | 1.5A | |
RATED POWER | 81.9W | 81.6W | 81W | |
RIPPLE & NOISE (max.) | 200mVp-p | 200mVp-p | 200mVp-p | |
VOLTAGE ADJ. RANGE - Adjustable forA-Type only (via built-in potentiometer) | 40 ~ 46V | 44 ~ 53V | 49 ~ 58V | |
CURRENT ADJ. RANGE - Adjustable forA-Type only (via built-in potentiometer) | 1.17 ~ 1.95A | 1.02 ~ 1.7A | 0.9 ~ 1.5A | |
VOLTAGE TOLERANCE | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±0.5% | ±0.5% | ±0.5% | |
SET UP TIME | 1200ms,200ms/115VAC 500ms,200ms/230VAC | 1200ms,200ms/115VAC 500ms,200ms/230VAC | 1200ms,200ms/115VAC 500ms,200ms/230VAC | |
HOLD UP TIME (Typ.) | 16ms at full load 230VAC /115VAC | 16ms at full load 230VAC /115VAC | 16ms at full load 230VAC /115VAC | |
INPUT | VOLTAGE RANGE | 90 ~ 305VAC 127 ~ 431VDC | 90 ~ 305VAC 127 ~ 431VDC | 90 ~ 305VAC 127 ~ 431VDC |
FREQUENCY RANGE | 47 ~ 63Hz | 47 ~ 63Hz | 47 ~ 63Hz | |
POWER FACTOR (Typ.) | PF>=0.96/115VAC, PF>=0.96/230VAC, PF>=0.94/277VAC @ full load | PF>=0.96/115VAC, PF>=0.96/230VAC, PF>=0.94/277VAC @ full load | PF>=0.96/115VAC, PF>=0.96/230VAC, PF>=0.94/277VAC @ full load | |
TOTAL HARMONIC DISTORTION | THD< 20% (@>=load 60% / 115VAC,230VAC; @ load>=75% / 277VAC) | THD< 20% (@>=load 60% / 115VAC,230VAC; @ load>=75% / 277VAC) | THD< 20% (@>=load 60% / 115VAC,230VAC; @ load>=75% / 277VAC) | |
EFFICIENCY (Typ.) | 91% | 91% | 91% | |
AC CURRENT (Typ.) | 0.85A/ 115VAC 0.425A/ 230VAC 0.4A/ 277VAC | 0.85A/ 115VAC 0.425A/ 230VAC 0.4A/ 277VAC | 0.85A/ 115VAC 0.425A/ 230VAC 0.4A/ 277VAC | |
INRUSH CURRENT(Typ.) | COLD START 70A(t =485 s measured at 50% I ) at 230VAC width peak ; Per NEMA410 | COLD START 70A(t =485 s measured at 50% I ) at 230VAC width peak ; Per NEMA410 | COLD START 70A(t =485 s measured at 50% I ) at 230VAC width peak ; Per NEMA410 | |
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 3 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC | 3 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC | 3 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC | |
LEAKAGE CURRENT | <0.75mA/ 277VAC | <0.75mA/ 277VAC | <0.75mA/ 277VAC | |
Specs Sheet |