HLG-600H series
600W Constant Voltage + Constant Current LED Driver
Application:
Features
Constant Voltage + Constant current mode ouput
Metal housing design with class 1 design
Standby power consumption < 0.5W at remote off
IP67 / IP65 design for indoor or outdoor installations
Function options: output adjustable via potentiometer
3 in 1 dimming(dim-to-off)
Typical lifetime > 62000 hours
7 year warranty
HLG-600H series
MODEL | HLG-600H-12 | HLG-600H-15 | HLG-600H-20 | |
---|---|---|---|---|
OUTPUT | DC VOLTAGE | 12V | 15V | 20V |
CONSTANT CURRENT REGION | 6 ~12V | 7.5 ~ 15V | 10 ~ 20V | |
RATED CURRENT | 40A | 36A | 28A | |
RATED POWER | 480W | 540W | 560W | |
RIPPLE & NOISE (max.) | 150mVp-p | 150mVp-p | 150mVp-p | |
VOLTAGE ADJ. RANGE - Adjustable forA-Type only (via built-in potentiometer) | 10.2 ~ 12.6V | 12.7 ~ 15.8V | 17 ~ 21V | |
CURRENT ADJ. RANGE - Adjustable forA-Type only (via built-in potentiometer) | 20 ~ 40A | 18 ~ 36A | 14 ~ 28A | |
VOLTAGE TOLERANCE | ± 3.0% | ± 2.0% | ± 1.5% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ± 2.0% | ± 1.5% | ± 1.0% | |
SET UP TIME | 500ms, 80ms / 115VAC, 230VAC | 500ms, 80ms / 115VAC, 230VAC | 500ms, 80ms / 115VAC, 230VAC | |
HOLD UP TIME (Typ.) | 15ms / 115VAC, 230VAC | 15ms / 115VAC, 230VAC | 15ms / 115VAC, 230VAC | |
INPUT | VOLTAGE RANGE | 90 ~ 305VAC 127 ~ 431VDC | 90 ~ 305VAC 127 ~ 431VDC | 90 ~ 305VAC 127 ~ 431VDC |
FREQUENCY RANGE | 47 ~ 63Hz | 47 ~ 63Hz | 47 ~ 63Hz | |
POWER FACTOR (Typ.) | PF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.93/277VAC @ full load | PF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.93/277VAC @ full load | PF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.93/277VAC @ full load | |
TOTAL HARMONIC DISTORTION | THD< 20% (@ load>=50% /115VAC, 230VAC; @ load>=75%/277VAC) | THD< 20% (@ load>=50% /115VAC, 230VAC; @ load>=75%/277VAC) | THD< 20% (@ load>=50% /115VAC, 230VAC; @ load>=75%/277VAC) | |
EFFICIENCY (Typ.) (230Vac) | 92% | 93.5% | 94.5% | |
EFFICIENCY (Typ.) (277Vac) | 92.5% | 93.5% | 94.5% | |
AC CURRENT (Typ.) | 7A/ 115VAC 3.3A/ 230VAC 2.9A/ 277VAC | 7A/ 115VAC 3.3A/ 230VAC 2.9A/ 277VAC | 7A/ 115VAC 3.3A/ 230VAC 2.9A/ 277VAC | |
INRUSH CURRENT(Typ.) | COLD START 70A(t =1000 s measured at 50% I ) at 230VAC; width peak Per NEMA410 | COLD START 70A(t =1000 s measured at 50% I ) at 230VAC; width peak Per NEMA410 | COLD START 70A(t =1000 s measured at 50% I ) at 230VAC; width peak Per NEMA410 | |
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 1 unit (circuit breaker of type B) / 2 units (circuit breaker of type C) at 230VAC | 1 unit (circuit breaker of type B) / 2 units (circuit breaker of type C) at 230VAC | 1 unit (circuit breaker of type B) / 2 units (circuit breaker of type C) at 230VAC | |
LEAKAGE CURRENT | <0.75mA/ 277VAC | <0.75mA/ 277VAC | <0.75mA/ 277VAC | |
Specs Sheet | ![]() | ![]() | ![]() |
HLG-600H series
MODEL | HLG-480H-24 | HLG-480H-30 | HLG-480H-36 | |
---|---|---|---|---|
OUTPUT | DC VOLTAGE | 24V | 30V | 36V |
CONSTANT CURRENT REGION | 12 ~ 24V | 15 ~ 30V | 18 ~ 36V | |
RATED CURRENT | 25A | 20A | 16.7A | |
RATED POWER | 600W | 600W | 601.2W | |
RIPPLE & NOISE (max.) | 150mVp-p | 200mVp-p | 250mVp-p | |
VOLTAGE ADJ. RANGE - Adjustable forA-Type only (via built-in potentiometer) | 20.4 ~ 25.2V | 25.5 ~ 31.5V | 30.6 ~ 37.8V | |
CURRENT ADJ. RANGE - Adjustable forA-Type only (via built-in potentiometer) | 12.5 ~ 25A | 10 ~ 20A | 8.3 ~ 16.7A | |
VOLTAGE TOLERANCE | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±0.5% | ±0.5% | ±0.5% | |
SET UP TIME | 500ms, 80ms 115VAC/230VAC | 500ms, 80ms 115VAC/230VAC | 500ms, 80ms 115VAC/230VAC | |
HOLD UP TIME (Typ.) | 15ms / 115VAC, 230VAC | 15ms / 115VAC, 230VAC | 15ms / 115VAC, 230VAC | |
INPUT | VOLTAGE RANGE | 90 ~ 305VAC 127 ~ 431VDC | 90 ~ 305VAC 127 ~ 431VDC | 90 ~ 305VAC 127 ~ 431VDC |
FREQUENCY RANGE | 47 ~ 63Hz | 47 ~ 63Hz | 47 ~ 63Hz | |
POWER FACTOR (Typ.) | PF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.93/277VAC @ full load | PF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.93/277VAC @ full load | PF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.93/277VAC @ full load | |
TOTAL HARMONIC DISTORTION | THD< 20% (@ load>=50% /115VAC, 230VAC; @ load>=75%/277VAC) | THD< 20% (@ load>=50% /115VAC, 230VAC; @ load>=75%/277VAC) | THD< 20% (@ load>=50% /115VAC, 230VAC; @ load>=75%/277VAC) | |
EFFICIENCY (Typ.) (230Vac) | 95% | 95% | 95.5% | |
EFFICIENCY (Typ.) (277Vac) | 95% | 95% | 95.5% | |
AC CURRENT (Typ.) | 7A/ 115VAC 3.3A/ 230VAC 2.9A/ 277VAC | 7A/ 115VAC 3.3A/ 230VAC 2.9A/ 277VAC | 7A/ 115VAC 3.3A/ 230VAC 2.9A/ 277VAC | |
INRUSH CURRENT(Typ.) | COLD START 70A(t =1000 s measured at 50% I ) at 230VAC; width peak Per NEMA410 | COLD START 70A(t =1000 s measured at 50% I ) at 230VAC; width peak Per NEMA410 | COLD START 70A(t =1000 s measured at 50% I ) at 230VAC; width peak Per NEMA410 | |
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 1 unit (circuit breaker of type B) / 2 units (circuit breaker of type C) at 230VAC | 1 unit (circuit breaker of type B) / 2 units (circuit breaker of type C) at 230VAC | 1 unit (circuit breaker of type B) / 2 units (circuit breaker of type C) at 230VAC | |
LEAKAGE CURRENT | <0.75mA/ 277VAC | <0.75mA/ 277VAC | <0.75mA/ 277VAC | |
Specs Sheet | ![]() | ![]() | ![]() | ![]() |
HLG-600H series
MODEL | HLG-480H-42 | HLG-480H-48 | HLG-480H-54 | |
---|---|---|---|---|
OUTPUT | DC VOLTAGE | 42V | 48V | 54V |
CONSTANT CURRENT REGION | 21 ~ 42V | 24 ~ 48V | 27 ~ 54V | |
RATED CURRENT | 14.3A | 12.5A | 11.2A | |
RATED POWER | 600.6W | 600W | 604.8W | |
RIPPLE & NOISE (max.) | 250mVp-p | 250mVp-p | 350mVp-p | |
VOLTAGE ADJ. RANGE - Adjustable forA-Type only (via built-in potentiometer) | 35.7 ~ 44.1V | 40.8 ~ 50.4V | 45.9 ~ 56.7V | |
CURRENT ADJ. RANGE - Adjustable forA-Type only (via built-in potentiometer) | 7.1 ~ 14.3A | 6.2 ~ 12.5A | 5.6 ~ 11.2A | |
VOLTAGE TOLERANCE | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±0.5% | ±0.5% | ±0.5% | |
SET UP TIME | 500ms, 80ms 115VAC/230VAC | 500ms, 80ms 115VAC/230VAC | 500ms, 80ms 115VAC/230VAC | |
HOLD UP TIME (Typ.) | 15ms / 115VAC, 230VAC | 15ms / 115VAC, 230VAC | 15ms / 115VAC, 230VAC | |
INPUT | VOLTAGE RANGE | 90 ~ 305VAC 127 ~ 431VDC | 90 ~ 305VAC 127 ~ 431VDC | 90 ~ 305VAC 127 ~ 431VDC |
FREQUENCY RANGE | 47 ~ 63Hz | 47 ~ 63Hz | 47 ~ 63Hz | |
POWER FACTOR (Typ.) | PF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.93/277VAC @ full load | PF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.93/277VAC @ full load | PF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.93/277VAC @ full load | |
TOTAL HARMONIC DISTORTION | THD< 20% (@ load>=50% /115VAC, 230VAC; @ load>=75%/277VAC) | THD< 20% (@ load>=50% /115VAC, 230VAC; @ load>=75%/277VAC) | THD< 20% (@ load>=50% /115VAC, 230VAC; @ load>=75%/277VAC) | |
EFFICIENCY (Typ.) (230Vac) | 96% | 96% | 96% | |
EFFICIENCY (Typ.) (277Vac) | 96% | 96% | 96% | |
AC CURRENT (Typ.) | 7A/ 115VAC 3.3A/ 230VAC 2.9A/ 277VAC | 7A/ 115VAC 3.3A/ 230VAC 2.9A/ 277VAC | 7A/ 115VAC 3.3A/ 230VAC 2.9A/ 277VAC | |
INRUSH CURRENT(Typ.) | COLD START 70A(t =1000 s measured at 50% I ) at 230VAC; width peak Per NEMA410 | COLD START 70A(t =1000 s measured at 50% I ) at 230VAC; width peak Per NEMA410 | COLD START 70A(t =1000 s measured at 50% I ) at 230VAC; width peak Per NEMA410 | |
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 1 unit (circuit breaker of type B) / 2 units (circuit breaker of type C) at 230VAC | 1 unit (circuit breaker of type B) / 2 units (circuit breaker of type C) at 230VAC | 1 unit (circuit breaker of type B) / 2 units (circuit breaker of type C) at 230VAC | |
LEAKAGE CURRENT | <0.75mA/ 277VAC | <0.75mA/ 277VAC | <0.75mA/ 277VAC | |
Specs Sheet | ![]() | ![]() | ![]() | ![]() |