PLN-30 series
30W Single Output LED Power Supply
NRCS LOA APPROVED
|
Application:
Features
Universal AC input / Fill range(up tp 295VAC)
Protections: Short circuit/ Over current/ Over Voltage/ Over temperature
Cooling by free air convection
Built-in constant current limiting circuit with adjustable OCP level
Fully isolated plastic case with IP64 level
Built-in active PFC function
Pass LPS
Class 2 power unit
Class 2 power unit, no FG
100% full load burn-in test
High reliability, low cost
Suitable for LED lighting and moving sign applications
Compliance to worldwide safety regulations for lighting
2 year warranty
PLN-30 series
MODEL | PLN-30-9 | PLN-30-12 | PLN-30-15 | PLN-30-20 | |
---|---|---|---|---|---|
OUTPUT | DC VOLTAGE | 9V | 12V | 15V | 20V |
CONSTANT CURRENT REGION | 6.3 ~ 9V | 8.4 ~ 12V | 10.5 ~ 15V | 14 ~ 20V | |
RATED CURRENT | 3.3A | 2.5A | 2A | 1.5A | |
CURRENT RANGE | 0 ~ 3.3A | 0 ~ 2.5A | 0 ~ 2A | 0 ~ 1.5A | |
RATED POWER | 29.7W | 30W | 30W | 30W | |
RIPPLE & NOISE (max.) | 2.6Vp-p | 2Vp-p | 2.6Vp-p | 2.6Vp-p | |
VOLTAGE ADJ. RANGE | -5% ~ 10%. Can be adjusted by internal potentiometer SVR1 | -5% ~ 10%. Can be adjusted by internal potentiometer SVR1 | -5% ~ 10%. Can be adjusted by internal potentiometer SVR1 | -5% ~ 10%. Can be adjusted by internal potentiometer SVR1 | |
CURRENT ADJ. RANGE | 3% ~ -25%. Can be adjusted by internal potentiometer SVR2 | 3% ~ -25%. Can be adjusted by internal potentiometer SVR2 | 3% ~ -25%. Can be adjusted by internal potentiometer SVR2 | 3% ~ -25%. Can be adjusted by internal potentiometer SVR2 | |
VOLTAGE TOLERANCE | -5% ~ 10%. Can be adjusted by internal potentiometer SVR1 | -5% ~ 10%. Can be adjusted by internal potentiometer SVR1 | -5% ~ 10%. Can be adjusted by internal potentiometer SVR1 | -5% ~ 10%. Can be adjusted by internal potentiometer SVR1 | |
LINE REGULATION | ±3.0% | ±3.0% | ±3.0% | ±3.0% | |
LOAD REGULATION | ±10% | ±10% | ±10% | ±10% | |
SETUP TIME | 500ms / 230VAC 3000ms / 115VAC at full load | 500ms / 230VAC 3000ms / 115VAC at full load | 500ms / 230VAC 3000ms / 115VAC at full load | 500ms / 230VAC 3000ms / 115VAC at full load | |
INPUT | VOLTAGE RANGE | 90 ~ 295VAC 127 ~ 417VDC | 90 ~ 295VAC 127 ~ 417VDC | 90 ~ 295VAC 127 ~ 417VDC | 90 ~ 295VAC 127 ~ 417VDC |
FREQUENCY RANGE | 47 ~ 63Hz | 47 ~ 63Hz | 47 ~ 63Hz | 47 ~ 63Hz | |
POWER FACTOR (Typ.) | PF>0.95/115VAC, PF>0.9/230VAC, PF>0.9/277VAC at full load | PF>0.95/115VAC, PF>0.9/230VAC, PF>0.9/277VAC at full load | PF>0.95/115VAC, PF>0.9/230VAC, PF>0.9/277VAC at full load | PF>0.95/115VAC, PF>0.9/230VAC, PF>0.9/277VAC at full load | |
TOTAL HARMONIC DISTORTION | THD< 20% when output loading 75% at 115VAC/230VAC input and output loading 80% at 277VAC input | THD< 20% when output loading 75% at 115VAC/230VAC input and output loading 80% at 277VAC input | THD< 20% when output loading 75% at 115VAC/230VAC input and output loading 80% at 277VAC input | THD< 20% when output loading 75% at 115VAC/230VAC input and output loading 80% at 277VAC input | |
EFFICIENCY (Typ.) | 80% | 82.5% | 83.5% | 84% | |
AC CURRENT | 0.4A/115VAC 0.2A/230VAC 0.15A/277VAC | 0.4A/115VAC 0.2A/230VAC 0.15A/277VAC | 0.4A/115VAC 0.2A/230VAC 0.15A/277VAC | 0.4A/115VAC 0.2A/230VAC 0.15A/277VAC | |
INRUSH CURRENT(Typ.) | COLD START 35A(twidth=25 s measured at 50% Ipeak) at 230VAC | COLD START 35A(twidth=25 s measured at 50% Ipeak) at 230VAC | COLD START 35A(twidth=25 s measured at 50% Ipeak) at 230VAC | COLD START 35A(twidth=25 s measured at 50% Ipeak) at 230VAC | |
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 64 units (circuit breaker of type B) / 64 units (circuit breaker of type C) at 230VAC | 64 units (circuit breaker of type B) / 64 units (circuit breaker of type C) at 230VAC | 64 units (circuit breaker of type B) / 64 units (circuit breaker of type C) at 230VAC | 64 units (circuit breaker of type B) / 64 units (circuit breaker of type C) at 230VAC | |
LEAKAGE CURRENT | 0.5mA/ 240VAC | 0.5mA/ 240VAC | 0.5mA/ 240VAC | 0.5mA/ 240VAC | |
Specs Sheet |
PLN-30 series
MODEL | PLN-30-24 | PLN-30-27 | PLN-30-36 | PLN-30-48 | |
---|---|---|---|---|---|
OUTPUT | DC VOLTAGE | 24V | 27V | 36V | 48V |
CONSTANT CURRENT REGION | 16.8 ~ 24V | 18.9 ~ 27V | 25.2 ~ 36V | 33.6 ~ 48V | |
RATED CURRENT | 1.25A | 1.12A | 0.84A | 0.63A | |
CURRENT RANGE | 0 ~ 1.25A | 0 ~ 1.12A | 0 ~ 0.84A | 0 ~ 0.63A | |
RATED POWER | 30W | 30.24W | 30.24W | 30.24W | |
RIPPLE & NOISE (max.) | 2.6Vp-p | 2.3Vp-p | 4.5Vp-p | 3.7Vp-p | |
VOLTAGE ADJ. RANGE | -5% ~ 10%. Can be adjusted by internal potentiometer SVR1 | -5% ~ 10%. Can be adjusted by internal potentiometer SVR1 | -5% ~ 10%. Can be adjusted by internal potentiometer SVR1 | -5% ~ 10%. Can be adjusted by internal potentiometer SVR1 | |
CURRENT ADJ. RANGE | 3% ~ -25%. Can be adjusted by internal potentiometer SVR2 | 3% ~ -25%. Can be adjusted by internal potentiometer SVR2 | 3% ~ -25%. Can be adjusted by internal potentiometer SVR2 | 3% ~ -25%. Can be adjusted by internal potentiometer SVR2 | |
VOLTAGE TOLERANCE | -5% ~ 10%. Can be adjusted by internal potentiometer SVR1 | -5% ~ 10%. Can be adjusted by internal potentiometer SVR1 | -5% ~ 10%. Can be adjusted by internal potentiometer SVR1 | -5% ~ 10%. Can be adjusted by internal potentiometer SVR1 | |
LINE REGULATION | ±3.0% | ±3.0% | ±3.0% | ±3.0% | |
LOAD REGULATION | ±10% | ±10% | ±10% | ±10% | |
SETUP TIME | 500ms / 230VAC 3000ms / 115VAC at full load | 500ms / 230VAC 3000ms / 115VAC at full load | 500ms / 230VAC 3000ms / 115VAC at full load | 500ms / 230VAC 3000ms / 115VAC at full load | |
INPUT | VOLTAGE RANGE | 90 ~ 295VAC 127 ~ 417VDC | 90 ~ 295VAC 127 ~ 417VDC | 90 ~ 295VAC 127 ~ 417VDC | 90 ~ 295VAC 127 ~ 417VDC |
FREQUENCY RANGE | 47 ~ 63Hz | 47 ~ 63Hz | 47 ~ 63Hz | 47 ~ 63Hz | |
POWER FACTOR (Typ.) | PF>0.95/115VAC, PF>0.9/230VAC, PF>0.9/277VAC at full load | PF>0.95/115VAC, PF>0.9/230VAC, PF>0.9/277VAC at full load | PF>0.95/115VAC, PF>0.9/230VAC, PF>0.9/277VAC at full load | PF>0.95/115VAC, PF>0.9/230VAC, PF>0.9/277VAC at full load | |
TOTAL HARMONIC DISTORTION | THD< 20% when output loading 75% at 115VAC/230VAC input and output loading 80% at 277VAC input | THD< 20% when output loading 75% at 115VAC/230VAC input and output loading 80% at 277VAC input | THD< 20% when output loading 75% at 115VAC/230VAC input and output loading 80% at 277VAC input | THD< 20% when output loading 75% at 115VAC/230VAC input and output loading 80% at 277VAC input | |
EFFICIENCY (Typ.) | 84% | 84.5% | 85% | 85.5% | |
AC CURRENT | 0.4A/115VAC 0.2A/230VAC 0.15A/277VAC | 0.4A/115VAC 0.2A/230VAC 0.15A/277VAC | 0.4A/115VAC 0.2A/230VAC 0.15A/277VAC | 0.4A/115VAC 0.2A/230VAC 0.15A/277VAC | |
INRUSH CURRENT(Typ.) | COLD START 35A(twidth=25 s measured at 50% Ipeak) at 230VAC | COLD START 35A(twidth=25 s measured at 50% Ipeak) at 230VAC | COLD START 35A(twidth=25 s measured at 50% Ipeak) at 230VAC | COLD START 35A(twidth=25 s measured at 50% Ipeak) at 230VAC | |
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 64 units (circuit breaker of type B) / 64 units (circuit breaker of type C) at 230VAC | 64 units (circuit breaker of type B) / 64 units (circuit breaker of type C) at 230VAC | 64 units (circuit breaker of type B) / 64 units (circuit breaker of type C) at 230VAC | 64 units (circuit breaker of type B) / 64 units (circuit breaker of type C) at 230VAC | |
LEAKAGE CURRENT | 0.5mA/ 240VAC | 0.5mA/ 240VAC | 0.5mA/ 240VAC | 0.5mA/ 240VAC | |
Specs Sheet |