LED Power Solutions

powered by Current Automation

NPF-60D series

60W Single Output LED Driver

Application:

LED decorative lighting
LED office lighting
Indoor LED lighting

Features

 Rastic housing with class 2 design
 Built-in active PFC function
 Class 2 power unit
 Standby power consumption<0.5W
 P67 rating for indoor or outdoor installations
 Function: 3 in 1 dimming(dim-to-off)
 Typical lifetime > 50000 hours
 5 years warranty

NPF-60D series

MODELNPF-60D-12NPF-60D-15NPF-60D-20
OUTPUTRATED CURRENT5A4A3A
RATED POWER60W60W60W
CONSTANT CURRENT REGION7.2 ~ 12V9 ~ 15V 12 ~ 20V
CURRENT RIPPLE 5.0% max. @rated current5.0% max. @rated current5.0% max. @rated current
CURRENT TOLERANCE±5.0%±5.0%±5.0%
SETUP TIME500ms/115VAC, 230VAC500ms/115VAC, 230VAC500ms/115VAC, 230VAC
INPUTVOLTAGE RANGE90 ~ 305VAC 127 ~ 431VDC90 ~ 305VAC 127 ~ 431VDC90 ~ 305VAC 127 ~ 431VDC
FREQUENCY RANGE47 ~ 63Hz47 ~ 63Hz47 ~ 63Hz
POWER FACTOR (Typ.)PF 0.97/115VAC, PF 0.95/230VAC, PF 0.92/277VAC@full loadPF 0.97/115VAC, PF 0.95/230VAC, PF 0.92/277VAC@full loadPF 0.97/115VAC, PF 0.95/230VAC, PF 0.92/277VAC@full load
TOTAL HARMONIC DISTORTIONTHD< 20%(@load 60%/115VC, 230VAC; @load 75%/277VAC)THD< 20%(@load 60%/115VC, 230VAC; @load 75%/277VAC)THD< 20%(@load 60%/115VC, 230VAC; @load 75%/277VAC)
EFFICIENCY (Typ.)86%87%88%
AC CURRENT0.8A/ 115VAC 0.4A/ 230VAC 0.32A/ 277VAC0.8A/ 115VAC 0.4A/ 230VAC 0.32A/ 277VAC0.8A/ 115VAC 0.4A/ 230VAC 0.32A/ 277VAC
INRUSH CURRENT(Typ.)COLD START 50A(twidth=270 s measured at 50% Ipeak) at 230VAC; Per NEMA410COLD START 50A(twidth=270 s measured at 50% Ipeak) at 230VAC; Per NEMA410COLD START 50A(twidth=270 s measured at 50% Ipeak) at 230VAC; Per NEMA410
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
9 units (circuit breaker of type B) / 16 units (circuit breaker of type C) at 230VAC9 units (circuit breaker of type B) / 16 units (circuit breaker of type C) at 230VAC9 units (circuit breaker of type B) / 16 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT<0.25mA/ 277VAC<0.25mA/ 277VAC<0.25mA/ 277VAC
STANDBYPOWER CONSUMPTION<0.5W <0.5W <0.5W
Specs Sheet
untitled-3Download PDF
untitled-3Download PDF
untitled-3Download PDF

NPF-60D series

MODELNPF-60D-24NPF-60D-30NPF-60D-36
OUTPUTRATED CURRENT2.5A2A1.67A
RATED POWER60W60W60W
CONSTANT CURRENT REGION14.4 ~ 24V18 ~ 30V 21.6 ~ 36V
CURRENT RIPPLE 5.0% max. @rated current5.0% max. @rated current5.0% max. @rated current
CURRENT TOLERANCE±5.0%±5.0%±5.0%
SETUP TIME500ms/115VAC, 230VAC500ms/115VAC, 230VAC500ms/115VAC, 230VAC
INPUTVOLTAGE RANGE90 ~ 305VAC 127 ~ 431VDC90 ~ 305VAC 127 ~ 431VDC90 ~ 305VAC 127 ~ 431VDC
FREQUENCY RANGE47 ~ 63Hz47 ~ 63Hz47 ~ 63Hz
POWER FACTOR (Typ.)PF 0.97/115VAC, PF 0.95/230VAC, PF 0.92/277VAC@full loadPF 0.97/115VAC, PF 0.95/230VAC, PF 0.92/277VAC@full loadPF 0.97/115VAC, PF 0.95/230VAC, PF 0.92/277VAC@full load
TOTAL HARMONIC DISTORTIONTHD< 20%(@load 60%/115VC, 230VAC; @load 75%/277VAC)THD< 20%(@load 60%/115VC, 230VAC; @load 75%/277VAC)THD< 20%(@load 60%/115VC, 230VAC; @load 75%/277VAC)
EFFICIENCY (Typ.)89%90% 90%
AC CURRENT0.8A/ 115VAC 0.4A/ 230VAC 0.32A/ 277VAC0.8A/ 115VAC 0.4A/ 230VAC 0.32A/ 277VAC0.8A/ 115VAC 0.4A/ 230VAC 0.32A/ 277VAC
INRUSH CURRENT(Typ.)COLD START 50A(twidth=270 s measured at 50% Ipeak) at 230VAC; Per NEMA410COLD START 50A(twidth=270 s measured at 50% Ipeak) at 230VAC; Per NEMA410COLD START 50A(twidth=270 s measured at 50% Ipeak) at 230VAC; Per NEMA410
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
9 units (circuit breaker of type B) / 16 units (circuit breaker of type C) at 230VAC9 units (circuit breaker of type B) / 16 units (circuit breaker of type C) at 230VAC9 units (circuit breaker of type B) / 16 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT<0.25mA/ 277VAC<0.25mA/ 277VAC<0.25mA/ 277VAC
STANDBYPOWER CONSUMPTION<0.5W <0.5W <0.5W
Specs Sheet
untitled-3Download PDF
untitled-3Download PDF
untitled-3Download PDF

NPF-60D series

MODELNPF-60D-42NPF-60D-48NPF-60D-54
OUTPUTRATED CURRENT1.43A 1.25A1.12A
RATED POWER60.06W60W60.48W
CONSTANT CURRENT REGION25.2 ~ 42V28.8 ~ 48V 32.4 ~ 54V
CURRENT RIPPLE 5.0% max. @rated current5.0% max. @rated current5.0% max. @rated current
CURRENT TOLERANCE±5.0%±5.0%±5.0%
SETUP TIME500ms/115VAC, 230VAC500ms/115VAC, 230VAC500ms/115VAC, 230VAC
INPUTVOLTAGE RANGE90 ~ 305VAC 127 ~ 431VDC90 ~ 305VAC 127 ~ 431VDC90 ~ 305VAC 127 ~ 431VDC
FREQUENCY RANGE47 ~ 63Hz47 ~ 63Hz47 ~ 63Hz
POWER FACTOR (Typ.)PF 0.97/115VAC, PF 0.95/230VAC, PF 0.92/277VAC@full loadPF 0.97/115VAC, PF 0.95/230VAC, PF 0.92/277VAC@full loadPF 0.97/115VAC, PF 0.95/230VAC, PF 0.92/277VAC@full load
TOTAL HARMONIC DISTORTIONTHD< 20%(@load 60%/115VC, 230VAC; @load 75%/277VAC)THD< 20%(@load 60%/115VC, 230VAC; @load 75%/277VAC)THD< 20%(@load 60%/115VC, 230VAC; @load 75%/277VAC)
EFFICIENCY (Typ.)90% 90% 90%
AC CURRENT0.8A/ 115VAC 0.4A/ 230VAC 0.32A/ 277VAC0.8A/ 115VAC 0.4A/ 230VAC 0.32A/ 277VAC0.8A/ 115VAC 0.4A/ 230VAC 0.32A/ 277VAC
INRUSH CURRENT(Typ.)COLD START 50A(twidth=270 s measured at 50% Ipeak) at 230VAC; Per NEMA410COLD START 50A(twidth=270 s measured at 50% Ipeak) at 230VAC; Per NEMA410COLD START 50A(twidth=270 s measured at 50% Ipeak) at 230VAC; Per NEMA410
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
9 units (circuit breaker of type B) / 16 units (circuit breaker of type C) at 230VAC9 units (circuit breaker of type B) / 16 units (circuit breaker of type C) at 230VAC9 units (circuit breaker of type B) / 16 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT<0.25mA/ 277VAC<0.25mA/ 277VAC<0.25mA/ 277VAC
STANDBYPOWER CONSUMPTION<0.5W <0.5W <0.5W
Specs Sheet
untitled-3Download PDF
untitled-3Download PDF
untitled-3Download PDF