PLN-60 series
60W Single Output LED Power Supply
NRCS LOA APPROVED
|
Application:
Features
Universal AC input / Fill range(up tp 295VAC)
High efficiency 89%
Protections: Short circuit/ Over current/ Over Voltage/ Over temperature
Cooling by free air convection
Built-in constant current limiting circuit with adjustable OCP level
Fully isolated plastic case with IP64 level
Built-in active PFC function
Pass LPS
Class 2 power unit
100% full load burn-in test
High reliability, low cost
Suitable for LED lighting and moving sign applications
Suitable for dry/damp locations
Compliance to worldwide safety regulations for lighting
2 year warranty
PLN-60 series
MODEL | PLN-60-12 | PLN-60-15 | PLN-60-20 | PLN-60-24 | |
---|---|---|---|---|---|
OUTPUT | DC VOLTAGE | 12V | 15V | 20V | 24V |
CONSTANT CURRENT REGION | 8.4 ~ 12V | 10.5 ~15V | 14 ~ 20V | 16.8 ~24V | |
RATED CURRENT | 5A | 4A | 3A | 2.5A | |
CURRENT RANGE | 0 ~ 5A | 0 ~ 4A | 0 ~ 3A | 0 ~ 2.5A | |
RATED POWER | 60W | 60W | 60W | 60W | |
RIPPLE & NOISE (max.) | 2Vp-p | 2.4Vp-p | 1.8Vp-p | 2.7Vp-p | |
VOLTAGE ADJ. RANGE(Can be adjusted by internal potentiometer SVR1) | 11.5 ~ 13V | 14.5 ~ 16.2V | 19.5 ~ 22V | 24 ~ 26V | |
CURRENT ADJ. RANGE | 3% ~ -25% | 3% ~ -25% | 3% ~ -25% | 3% ~ -25% | |
VOLTAGE TOLERANCE(Can be adjusted by internal potentiometer SVR2) | ±10% | ±10% | ±10% | ±10% | |
LINE REGULATION | ±3.0% | ±3.0% | ±3.0% | ±3.0% | |
LOAD REGULATION | ±5.0% | ±5.0% | ±5.0% | ±5.0% | |
SETUP TIME | 500ms / 230VAC 3000ms / 115VAC at full load | 500ms / 230VAC 3000ms / 115VAC at full load | 500ms / 230VAC 3000ms / 115VAC at full load | 500ms / 230VAC 3000ms / 115VAC at full load | |
INPUT | VOLTAGE RANGE | 90 ~ 295VAC 127 ~ 417VDC | 90 ~ 295VAC 127 ~ 417VDC | 90 ~ 295VAC 127 ~ 417VDC | 90 ~ 295VAC 127 ~ 417VDC |
FREQUENCY RANGE | 47 ~ 63Hz | 47 ~ 63Hz | 47 ~ 63Hz | 47 ~ 63Hz | |
POWER FACTOR (Typ.) | PF>0.92/115VAC, PF>0.9/230VAC, PF>0.9/277VAC at full load | PF>0.92/115VAC, PF>0.9/230VAC, PF>0.9/277VAC at full load | PF>0.92/115VAC, PF>0.9/230VAC, PF>0.9/277VAC at full load | PF>0.92/115VAC, PF>0.9/230VAC, PF>0.9/277VAC at full load | |
TOTAL HARMONIC DISTORTION | THD< 20% when output loading 75% at 115VAC/230VAC input and output loading 80% at 277VAC input | THD< 20% when output loading 75% at 115VAC/230VAC input and output loading 80% at 277VAC input | THD< 20% when output loading 75% at 115VAC/230VAC input and output loading 80% at 277VAC input | THD< 20% when output loading 75% at 115VAC/230VAC input and output loading 80% at 277VAC input | |
EFFICIENCY (Typ.) | 85% | 86% | 87.5% | 87% | |
AC CURRENT | 0.8A/115VAC 0.4A/230VAC 0.3A/277VAC | 0.8A/115VAC 0.4A/230VAC 0.3A/277VAC | 0.8A/115VAC 0.4A/230VAC 0.3A/277VAC | 0.8A/115VAC 0.4A/230VAC 0.3A/277VAC | |
INRUSH CURRENT(Typ.) | COLD START 35A(twidth=45 s measured at 50% Ipeak) at 230VAC | COLD START 35A(twidth=45 s measured at 50% Ipeak) at 230VAC | COLD START 35A(twidth=45 s measured at 50% Ipeak) at 230VAC | COLD START 35A(twidth=45 s measured at 50% Ipeak) at 230VAC | |
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 32 units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 230VAC | 32 units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 230VAC | 32 units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 230VAC | 32 units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 230VAC | |
LEAKAGE CURRENT | <0.75mA/ 240VAC | <0.75mA/ 240VAC | <0.75mA/ 240VAC | <0.75mA/ 240VAC | |
Specs Sheet |
PLN-60 series
MODEL | PLN-60-27 | PLN-60-36 | PLN-60-48 | |
---|---|---|---|---|
OUTPUT | DC VOLTAGE | 27V | 36V | 48V |
CONSTANT CURRENT REGION | 18.9 ~27V | 25.2 ~ 36V | 33.6 ~ 48V | |
RATED CURRENT | 2.3A | 1.7A | 1.3A | |
CURRENT RANGE | 0 ~ 2.3A | 0 ~ 1.7A | 0 ~ 1.3A | |
RATED POWER | 62.1W | 61.2W | 62.4W | |
RIPPLE & NOISE (max.) | 2.7Vp-p | 3.6Vp-p | 4.6Vp-p | |
VOLTAGE ADJ. RANGE(Can be adjusted by internal potentiometer SVR1) | 25 ~ 30V | 32.5 ~ 39V | 43.6 ~ 51.8V | |
CURRENT ADJ. RANGE | 3% ~ -25% | 3% ~ -25% | 3% ~ -25% | |
VOLTAGE TOLERANCE(Can be adjusted by internal potentiometer SVR2) | ±10% | ±10% | ±10% | |
LINE REGULATION | ±3.0% | ±3.0% | ±3.0% | |
LOAD REGULATION | ±5.0% | ±5.0% | ±5.0% | |
SETUP TIME | 500ms / 230VAC 3000ms / 115VAC at full load | 500ms / 230VAC 3000ms / 115VAC at full load | 500ms / 230VAC 3000ms / 115VAC at full load | |
INPUT | VOLTAGE RANGE | 90 ~ 295VAC 127 ~ 417VDC | 90 ~ 295VAC 127 ~ 417VDC | 90 ~ 295VAC 127 ~ 417VDC |
FREQUENCY RANGE | 47 ~ 63Hz | 47 ~ 63Hz | 47 ~ 63Hz | |
POWER FACTOR (Typ.) | PF>0.92/115VAC, PF>0.9/230VAC, PF>0.9/277VAC at full load | PF>0.92/115VAC, PF>0.9/230VAC, PF>0.9/277VAC at full load | PF>0.92/115VAC, PF>0.9/230VAC, PF>0.9/277VAC at full load | |
TOTAL HARMONIC DISTORTION | THD< 20% when output loading 75% at 115VAC/230VAC input and output loading 80% at 277VAC input | THD< 20% when output loading 75% at 115VAC/230VAC input and output loading 80% at 277VAC input | THD< 20% when output loading 75% at 115VAC/230VAC input and output loading 80% at 277VAC input | |
EFFICIENCY (Typ.) | 88% | 89% | 89% | |
AC CURRENT | 0.8A/115VAC 0.4A/230VAC 0.3A/277VAC | 0.8A/115VAC 0.4A/230VAC 0.3A/277VAC | 0.8A/115VAC 0.4A/230VAC 0.3A/277VAC | |
INRUSH CURRENT(Typ.) | COLD START 35A(twidth=45 s measured at 50% Ipeak) at 230VAC | COLD START 35A(twidth=45 s measured at 50% Ipeak) at 230VAC | COLD START 35A(twidth=45 s measured at 50% Ipeak) at 230VAC | |
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 32 units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 230VAC | 32 units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 230VAC | 32 units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 230VAC | |
LEAKAGE CURRENT | <0.75mA/ 240VAC | <0.75mA/ 240VAC | <0.75mA/ 240VAC | |
Specs Sheet |