LED Power Solutions

powered by Current Automation

HLG-120H-C series

150W Constant Current Mode LED Driver

Application:

LED Lighting
LED Moving Sign

Features

 Constant current mode ouput
 Metal housing design with class 1 design
 Built-in active PFC function
 IP67 / IP65 design for indoor or outdoor installations
 Function options: output adjustable via potentiometer
 3 in 1 dimming
 Timer dimmer
 Typical lifetime > 62000 hours
 7 year warranty

HLG-120H-C series

MODELHLG-120H-C350HLG-120H-C500HLG-120H-C700
OUTPUTRATED CURRENT350mA500mA700mA
RATED POWER150.5W150W150.5W
CONSTANT CURRENT REGION215 ~ 430V150V ~ 300V 107V ~ 215V
CURRENT ADJ. RANGE175 ~ 350mA 250 ~ 500mA 350 ~ 700mA
CURRENT RIPPLE8.0% max. @rated current8.0% max. @rated current8.0% max. @rated current
CURRENT TOLERANCE± 5%± 5%± 5%
SET UP TIME1000ms / 115VAC 500ms / 230VAC1000ms / 115VAC 500ms / 230VAC1000ms / 115VAC 500ms / 230VAC
INPUTVOLTAGE RANGE90 ~ 305VAC 127 ~ 431VDC90 ~ 305VAC 127 ~ 431VDC90 ~ 305VAC 127 ~ 431VDC
FREQUENCY RANGE47 ~ 63Hz47 ~ 63Hz47 ~ 63Hz
POWER FACTOR (Typ.)PF>=0.98/115VAC, PF>=0.96/230, PF>=0.93/277VAC @ full loadPF>=0.98/115VAC, PF>=0.96/230, PF>=0.93/277VAC @ full loadPF>=0.98/115VAC, PF>=0.96/230, PF>=0.93/277VAC @ full load
TOTAL HARMONIC DISTORTIONTHD< 20% (@ load>=50% /115VAC, 230VAC; @ load>=75%/277VAC)THD< 20% (@ load>=50% /115VAC, 230VAC; @ load>=75%/277VAC)THD< 20% (@ load>=50% /115VAC, 230VAC; @ load>=75%/277VAC)
EFFICIENCY (Typ.)94%94%94%
AC CURRENT (Typ.)1.6A/ 115VAC 0.8A/ 230VAC 0.7A/ 277VAC1.6A/ 115VAC 0.8A/ 230VAC 0.7A/ 277VAC1.6A/ 115VAC 0.8A/ 230VAC 0.7A/ 277VAC
INRUSH CURRENT(Typ.)COLD START 50A(t =600 s measured at 50% I ) at 230VAC; width peak Per NEMA410COLD START 50A(t =600 s measured at 50% I ) at 230VAC; width peak Per NEMA410COLD START 50A(t =600 s measured at 50% I ) at 230VAC; width peak Per NEMA410
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
4 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC4 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC4 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT<0.75mA/ 277VAC<0.75mA/ 277VAC<0.75mA/ 277VAC
Specs Sheet
untitled-3Download PDF
untitled-3Download PDF
untitled-3Download PDF

HLG-120H-C series

MODELHLG-120H-C1050HLG-120H-C1400
OUTPUTRATED CURRENT1050mA1400mA
RATED POWER155.4W151.2W
CONSTANT CURRENT REGION74V ~ 148V 54V ~ 108V
CURRENT ADJ. RANGE525 ~ 1050mA 700 ~ 1400mA
CURRENT RIPPLE8.0% max. @rated current8.0% max. @rated current
CURRENT TOLERANCE± 5%± 5%
SET UP TIME1000ms / 115VAC 500ms / 230VAC1000ms / 115VAC 500ms / 230VAC
INPUTVOLTAGE RANGE90 ~ 305VAC 127 ~ 431VDC90 ~ 305VAC 127 ~ 431VDC
FREQUENCY RANGE47 ~ 63Hz47 ~ 63Hz
POWER FACTOR (Typ.)PF>=0.98/115VAC, PF>=0.96/230, PF>=0.93/277VAC @ full loadPF>=0.98/115VAC, PF>=0.96/230, PF>=0.93/277VAC @ full load
TOTAL HARMONIC DISTORTIONTHD< 20% (@ load>=50% /115VAC, 230VAC; @ load>=75%/277VAC)THD< 20% (@ load>=50% /115VAC, 230VAC; @ load>=75%/277VAC)
EFFICIENCY (Typ.)94%93.5%
AC CURRENT (Typ.)1.6A/ 115VAC 0.8A/ 230VAC 0.7A/ 277VAC1.6A/ 115VAC 0.8A/ 230VAC 0.7A/ 277VAC
INRUSH CURRENT(Typ.)COLD START 50A(t =600 s measured at 50% I ) at 230VAC; width peak Per NEMA410COLD START 50A(t =600 s measured at 50% I ) at 230VAC; width peak Per NEMA410
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
4 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC4 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT<0.75mA/ 277VAC<0.75mA/ 277VAC
Specs Sheet