HLG-120H series

120W Constant Voltage + Constant Current LED Driver

NRCS LOA APPROVED

 

 

Application:

LED Lighting
LED Moving Sign

Features

 Constant Voltage + Constant current mode ouput
 Metal housing design with class 1 design
 Built-in active PFC function
 Class 2 power unit
 IP67 / IP65 design for indoor or outdoor installations
 Function options: output adjustable via potentiometer
 3 in 1 dimming (dim-to-off)
 Timer Dimming
 Typical lifetime > 62000 hours
 7 year warranty

HLG-120H series

MODELHLG-120H-12HLG-120H-15HLG-120H-20
OUTPUTDC VOLTAGE12V15V20V
CONSTANT CURRENT REGION6 ~12V 7.5 ~ 15V 10 ~ 20V
RATED CURRENT10A8A6A
RATED POWER120W120W120W
RIPPLE & NOISE (max.)150mVp-p150mVp-p150mVp-p
VOLTAGE ADJ. RANGE - Adjustable forA-Type only (via built-in potentiometer)10.8 ~ 13.5V13.5 ~ 17V17 ~ 22V
CURRENT ADJ. RANGE - Adjustable forA-Type only (via built-in potentiometer)5 ~ 10A4 ~ 8A3 ~ 6A
VOLTAGE TOLERANCE±2.5%±2.0%±1.0%
LINE REGULATION±0.5%±0.5%±0.5%
LOAD REGULATION±2.0%±1.5%±0.5%
SET UP TIME1200ms,50ms/115VAC 500ms,50ms/230VAC1200ms,50ms/115VAC 500ms,50ms/230VAC1200ms,50ms/115VAC 500ms,50ms/230VAC
HOLD UP TIME (Typ.)12ms / 115VAC, 230VAC12ms / 115VAC, 230VAC12ms / 115VAC, 230VAC
INPUTVOLTAGE RANGE90 ~ 305VAC 127 ~ 431VDC90 ~ 305VAC 127 ~ 431VDC90 ~ 305VAC 127 ~ 431VDC
FREQUENCY RANGE47 ~ 63Hz47 ~ 63Hz47 ~ 63Hz
POWER FACTOR (Typ.)PF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.93/277VAC @ full loadPF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.93/277VAC @ full loadPF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.93/277VAC @ full load
TOTAL HARMONIC DISTORTIONTHD< 20% (@>=load 50% / 115VAC,230VAC; @ load>=75% / 277VAC)THD< 20% (@>=load 50% / 115VAC,230VAC; @ load>=75% / 277VAC)THD< 20% (@>=load 50% / 115VAC,230VAC; @ load>=75% / 277VAC)
EFFICIENCY (Typ.)92%92%93%
AC CURRENT (Typ.)1.4A/ 115VAC 0.6A/ 230VAC 0.55A/ 277VAC1.4A/ 115VAC 0.6A/ 230VAC 0.55A/ 277VAC1.4A/ 115VAC 0.6A/ 230VAC 0.55A/ 277VAC
INRUSH CURRENT(Typ.)COLD START 60A(t =375 s measured at 50% I ) at 230VAC; width peak Per NEMA410COLD START 60A(t =375 s measured at 50% I ) at 230VAC; width peak Per NEMA410COLD START 60A(t =375 s measured at 50% I ) at 230VAC; width peak Per NEMA410
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
5 units (circuit breaker of type B) / 9 units (circuit breaker of type C) at 230VAC5 units (circuit breaker of type B) / 9 units (circuit breaker of type C) at 230VAC5 units (circuit breaker of type B) / 9 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT<0.75mA/ 277VAC<0.75mA/ 277VAC<0.75mA/ 277VAC
Specs Sheet
untitled-3Download PDF
untitled-3Download PDF
untitled-3Download PDF

HLG-120H series

MODELHLG-120H-24HLG-120H-30HLG-120H-36
OUTPUTDC VOLTAGE24V30V36V
CONSTANT CURRENT REGION12 ~ 24V 15 ~ 30V18 ~ 36V
RATED CURRENT5A4A3.4A
RATED POWER120W120W122.4W
RIPPLE & NOISE (max.)150mVp-p200mVp-p200mVp-p
VOLTAGE ADJ. RANGE - Adjustable forA-Type only (via built-in potentiometer)22 ~ 27V27 ~ 33V33 ~ 40V
CURRENT ADJ. RANGE - Adjustable forA-Type only (via built-in potentiometer)2.5 ~ 5A2 ~ 4A1.7 ~ 3.4A
VOLTAGE TOLERANCE±1.0%±1.0%±1.0%
LINE REGULATION±0.5%±0.5%±0.5%
LOAD REGULATION±0.5%±0.5%±0.5%
SET UP TIME1200ms,50ms/115VAC 500ms,50ms/230VAC1200ms,50ms/115VAC 500ms,50ms/230VAC1200ms,50ms/115VAC 500ms,50ms/230VAC
HOLD UP TIME (Typ.)12ms / 115VAC, 230VAC12ms / 115VAC, 230VAC12ms / 115VAC, 230VAC
INPUTVOLTAGE RANGE90 ~ 305VAC 127 ~ 431VDC90 ~ 305VAC 127 ~ 431VDC90 ~ 305VAC 127 ~ 431VDC
FREQUENCY RANGE47 ~ 63Hz47 ~ 63Hz47 ~ 63Hz
POWER FACTOR (Typ.)PF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.93/277VAC @ full loadPF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.93/277VAC @ full loadPF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.93/277VAC @ full load
TOTAL HARMONIC DISTORTIONTHD< 20% (@>=load 50% / 115VAC,230VAC; @ load>=75% / 277VAC)THD< 20% (@>=load 50% / 115VAC,230VAC; @ load>=75% / 277VAC)THD< 20% (@>=load 50% / 115VAC,230VAC; @ load>=75% / 277VAC)
EFFICIENCY (Typ.)93% 93% 93%
AC CURRENT (Typ.)1.4A/ 115VAC 0.6A/ 230VAC 0.55A/ 277VAC1.4A/ 115VAC 0.6A/ 230VAC 0.55A/ 277VAC1.4A/ 115VAC 0.6A/ 230VAC 0.55A/ 277VAC
INRUSH CURRENT(Typ.)COLD START 60A(t =375 s measured at 50% I ) at 230VAC; width peak Per NEMA410COLD START 60A(t =375 s measured at 50% I ) at 230VAC; width peak Per NEMA410COLD START 60A(t =375 s measured at 50% I ) at 230VAC; width peak Per NEMA410
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
5 units (circuit breaker of type B) / 9 units (circuit breaker of type C) at 230VAC5 units (circuit breaker of type B) / 9 units (circuit breaker of type C) at 230VAC5 units (circuit breaker of type B) / 9 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT<0.75mA/ 277VAC<0.75mA/ 277VAC<0.75mA/ 277VAC
Specs Sheet
untitled-3Download PDF
untitled-3Download PDF
untitled-3Download PDF

HLG-120H series

MODELHLG-120H-42HLG-120H-48HLG-120H-54
OUTPUTDC VOLTAGE42V48V54V
CONSTANT CURRENT REGION21 ~ 42V24 ~ 48V27 ~ 54V
RATED CURRENT2.9A2.5A2.3A
RATED POWER121.8W120W124.2W
RIPPLE & NOISE (max.)200mVp-p200mVp-p200mVp-p
VOLTAGE ADJ. RANGE - Adjustable forA-Type only (via built-in potentiometer)40 ~ 46V44 ~ 53V49 ~ 58V
CURRENT ADJ. RANGE - Adjustable forA-Type only (via built-in potentiometer)1.4 ~ 2.9A1.2 ~ 2.5A1.1 ~ 2.3A
VOLTAGE TOLERANCE±1.0%±1.0%±1.0%
LINE REGULATION±0.5%±0.5%±0.5%
LOAD REGULATION±0.5%±0.5%±0.5%
SET UP TIME1200ms,50ms/115VAC 500ms,50ms/230VAC1200ms,50ms/115VAC 500ms,50ms/230VAC1200ms,50ms/115VAC 500ms,50ms/230VAC
HOLD UP TIME (Typ.)12ms / 115VAC, 230VAC12ms / 115VAC, 230VAC12ms / 115VAC, 230VAC
INPUTVOLTAGE RANGE90 ~ 305VAC 127 ~ 431VDC90 ~ 305VAC 127 ~ 431VDC90 ~ 305VAC 127 ~ 431VDC
FREQUENCY RANGE47 ~ 63Hz47 ~ 63Hz47 ~ 63Hz
POWER FACTOR (Typ.)PF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.93/277VAC @ full loadPF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.93/277VAC @ full loadPF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.93/277VAC @ full load
TOTAL HARMONIC DISTORTIONTHD< 20% (@>=load 50% / 115VAC,230VAC; @ load>=75% / 277VAC)THD< 20% (@>=load 50% / 115VAC,230VAC; @ load>=75% / 277VAC)THD< 20% (@>=load 50% / 115VAC,230VAC; @ load>=75% / 277VAC)
EFFICIENCY (Typ.)93% 93.5% 93.5%
AC CURRENT (Typ.)1.4A/ 115VAC 0.6A/ 230VAC 0.55A/ 277VAC1.4A/ 115VAC 0.6A/ 230VAC 0.55A/ 277VAC1.4A/ 115VAC 0.6A/ 230VAC 0.55A/ 277VAC
INRUSH CURRENT(Typ.)COLD START 60A(t =375 s measured at 50% I ) at 230VAC; width peak Per NEMA410COLD START 60A(t =375 s measured at 50% I ) at 230VAC; width peak Per NEMA410COLD START 60A(t =375 s measured at 50% I ) at 230VAC; width peak Per NEMA410
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
5 units (circuit breaker of type B) / 9 units (circuit breaker of type C) at 230VAC5 units (circuit breaker of type B) / 9 units (circuit breaker of type C) at 230VAC5 units (circuit breaker of type B) / 9 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT<0.75mA/ 277VAC<0.75mA/ 277VAC<0.75mA/ 277VAC