HLG-120H series
120W Constant Voltage + Constant Current LED Driver
NRCS LOA APPROVED
|
Application:
Features
Constant Voltage + Constant current mode ouput
Metal housing design with class 1 design
Built-in active PFC function
Class 2 power unit
IP67 / IP65 design for indoor or outdoor installations
Function options: output adjustable via potentiometer
3 in 1 dimming (dim-to-off)
Timer Dimming
Typical lifetime > 62000 hours
7 year warranty
HLG-120H series
MODEL | HLG-120H-12 | HLG-120H-15 | HLG-120H-20 | |
---|---|---|---|---|
OUTPUT | DC VOLTAGE | 12V | 15V | 20V |
CONSTANT CURRENT REGION | 6 ~12V | 7.5 ~ 15V | 10 ~ 20V | |
RATED CURRENT | 10A | 8A | 6A | |
RATED POWER | 120W | 120W | 120W | |
RIPPLE & NOISE (max.) | 150mVp-p | 150mVp-p | 150mVp-p | |
VOLTAGE ADJ. RANGE - Adjustable forA-Type only (via built-in potentiometer) | 10.8 ~ 13.5V | 13.5 ~ 17V | 17 ~ 22V | |
CURRENT ADJ. RANGE - Adjustable forA-Type only (via built-in potentiometer) | 5 ~ 10A | 4 ~ 8A | 3 ~ 6A | |
VOLTAGE TOLERANCE | ±2.5% | ±2.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±2.0% | ±1.5% | ±0.5% | |
SET UP TIME | 1200ms,50ms/115VAC 500ms,50ms/230VAC | 1200ms,50ms/115VAC 500ms,50ms/230VAC | 1200ms,50ms/115VAC 500ms,50ms/230VAC | |
HOLD UP TIME (Typ.) | 12ms / 115VAC, 230VAC | 12ms / 115VAC, 230VAC | 12ms / 115VAC, 230VAC | |
INPUT | VOLTAGE RANGE | 90 ~ 305VAC 127 ~ 431VDC | 90 ~ 305VAC 127 ~ 431VDC | 90 ~ 305VAC 127 ~ 431VDC |
FREQUENCY RANGE | 47 ~ 63Hz | 47 ~ 63Hz | 47 ~ 63Hz | |
POWER FACTOR (Typ.) | PF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.93/277VAC @ full load | PF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.93/277VAC @ full load | PF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.93/277VAC @ full load | |
TOTAL HARMONIC DISTORTION | THD< 20% (@>=load 50% / 115VAC,230VAC; @ load>=75% / 277VAC) | THD< 20% (@>=load 50% / 115VAC,230VAC; @ load>=75% / 277VAC) | THD< 20% (@>=load 50% / 115VAC,230VAC; @ load>=75% / 277VAC) | |
EFFICIENCY (Typ.) | 92% | 92% | 93% | |
AC CURRENT (Typ.) | 1.4A/ 115VAC 0.6A/ 230VAC 0.55A/ 277VAC | 1.4A/ 115VAC 0.6A/ 230VAC 0.55A/ 277VAC | 1.4A/ 115VAC 0.6A/ 230VAC 0.55A/ 277VAC | |
INRUSH CURRENT(Typ.) | COLD START 60A(t =375 s measured at 50% I ) at 230VAC; width peak Per NEMA410 | COLD START 60A(t =375 s measured at 50% I ) at 230VAC; width peak Per NEMA410 | COLD START 60A(t =375 s measured at 50% I ) at 230VAC; width peak Per NEMA410 | |
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 5 units (circuit breaker of type B) / 9 units (circuit breaker of type C) at 230VAC | 5 units (circuit breaker of type B) / 9 units (circuit breaker of type C) at 230VAC | 5 units (circuit breaker of type B) / 9 units (circuit breaker of type C) at 230VAC | |
LEAKAGE CURRENT | <0.75mA/ 277VAC | <0.75mA/ 277VAC | <0.75mA/ 277VAC | |
Specs Sheet |
HLG-120H series
MODEL | HLG-120H-24 | HLG-120H-30 | HLG-120H-36 | |
---|---|---|---|---|
OUTPUT | DC VOLTAGE | 24V | 30V | 36V |
CONSTANT CURRENT REGION | 12 ~ 24V | 15 ~ 30V | 18 ~ 36V | |
RATED CURRENT | 5A | 4A | 3.4A | |
RATED POWER | 120W | 120W | 122.4W | |
RIPPLE & NOISE (max.) | 150mVp-p | 200mVp-p | 200mVp-p | |
VOLTAGE ADJ. RANGE - Adjustable forA-Type only (via built-in potentiometer) | 22 ~ 27V | 27 ~ 33V | 33 ~ 40V | |
CURRENT ADJ. RANGE - Adjustable forA-Type only (via built-in potentiometer) | 2.5 ~ 5A | 2 ~ 4A | 1.7 ~ 3.4A | |
VOLTAGE TOLERANCE | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±0.5% | ±0.5% | ±0.5% | |
SET UP TIME | 1200ms,50ms/115VAC 500ms,50ms/230VAC | 1200ms,50ms/115VAC 500ms,50ms/230VAC | 1200ms,50ms/115VAC 500ms,50ms/230VAC | |
HOLD UP TIME (Typ.) | 12ms / 115VAC, 230VAC | 12ms / 115VAC, 230VAC | 12ms / 115VAC, 230VAC | |
INPUT | VOLTAGE RANGE | 90 ~ 305VAC 127 ~ 431VDC | 90 ~ 305VAC 127 ~ 431VDC | 90 ~ 305VAC 127 ~ 431VDC |
FREQUENCY RANGE | 47 ~ 63Hz | 47 ~ 63Hz | 47 ~ 63Hz | |
POWER FACTOR (Typ.) | PF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.93/277VAC @ full load | PF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.93/277VAC @ full load | PF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.93/277VAC @ full load | |
TOTAL HARMONIC DISTORTION | THD< 20% (@>=load 50% / 115VAC,230VAC; @ load>=75% / 277VAC) | THD< 20% (@>=load 50% / 115VAC,230VAC; @ load>=75% / 277VAC) | THD< 20% (@>=load 50% / 115VAC,230VAC; @ load>=75% / 277VAC) | |
EFFICIENCY (Typ.) | 93% | 93% | 93% | |
AC CURRENT (Typ.) | 1.4A/ 115VAC 0.6A/ 230VAC 0.55A/ 277VAC | 1.4A/ 115VAC 0.6A/ 230VAC 0.55A/ 277VAC | 1.4A/ 115VAC 0.6A/ 230VAC 0.55A/ 277VAC | |
INRUSH CURRENT(Typ.) | COLD START 60A(t =375 s measured at 50% I ) at 230VAC; width peak Per NEMA410 | COLD START 60A(t =375 s measured at 50% I ) at 230VAC; width peak Per NEMA410 | COLD START 60A(t =375 s measured at 50% I ) at 230VAC; width peak Per NEMA410 | |
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 5 units (circuit breaker of type B) / 9 units (circuit breaker of type C) at 230VAC | 5 units (circuit breaker of type B) / 9 units (circuit breaker of type C) at 230VAC | 5 units (circuit breaker of type B) / 9 units (circuit breaker of type C) at 230VAC | |
LEAKAGE CURRENT | <0.75mA/ 277VAC | <0.75mA/ 277VAC | <0.75mA/ 277VAC | |
Specs Sheet |
HLG-120H series
MODEL | HLG-120H-42 | HLG-120H-48 | HLG-120H-54 | |
---|---|---|---|---|
OUTPUT | DC VOLTAGE | 42V | 48V | 54V |
CONSTANT CURRENT REGION | 21 ~ 42V | 24 ~ 48V | 27 ~ 54V | |
RATED CURRENT | 2.9A | 2.5A | 2.3A | |
RATED POWER | 121.8W | 120W | 124.2W | |
RIPPLE & NOISE (max.) | 200mVp-p | 200mVp-p | 200mVp-p | |
VOLTAGE ADJ. RANGE - Adjustable forA-Type only (via built-in potentiometer) | 40 ~ 46V | 44 ~ 53V | 49 ~ 58V | |
CURRENT ADJ. RANGE - Adjustable forA-Type only (via built-in potentiometer) | 1.4 ~ 2.9A | 1.2 ~ 2.5A | 1.1 ~ 2.3A | |
VOLTAGE TOLERANCE | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±0.5% | ±0.5% | ±0.5% | |
SET UP TIME | 1200ms,50ms/115VAC 500ms,50ms/230VAC | 1200ms,50ms/115VAC 500ms,50ms/230VAC | 1200ms,50ms/115VAC 500ms,50ms/230VAC | |
HOLD UP TIME (Typ.) | 12ms / 115VAC, 230VAC | 12ms / 115VAC, 230VAC | 12ms / 115VAC, 230VAC | |
INPUT | VOLTAGE RANGE | 90 ~ 305VAC 127 ~ 431VDC | 90 ~ 305VAC 127 ~ 431VDC | 90 ~ 305VAC 127 ~ 431VDC |
FREQUENCY RANGE | 47 ~ 63Hz | 47 ~ 63Hz | 47 ~ 63Hz | |
POWER FACTOR (Typ.) | PF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.93/277VAC @ full load | PF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.93/277VAC @ full load | PF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.93/277VAC @ full load | |
TOTAL HARMONIC DISTORTION | THD< 20% (@>=load 50% / 115VAC,230VAC; @ load>=75% / 277VAC) | THD< 20% (@>=load 50% / 115VAC,230VAC; @ load>=75% / 277VAC) | THD< 20% (@>=load 50% / 115VAC,230VAC; @ load>=75% / 277VAC) | |
EFFICIENCY (Typ.) | 93% | 93.5% | 93.5% | |
AC CURRENT (Typ.) | 1.4A/ 115VAC 0.6A/ 230VAC 0.55A/ 277VAC | 1.4A/ 115VAC 0.6A/ 230VAC 0.55A/ 277VAC | 1.4A/ 115VAC 0.6A/ 230VAC 0.55A/ 277VAC | |
INRUSH CURRENT(Typ.) | COLD START 60A(t =375 s measured at 50% I ) at 230VAC; width peak Per NEMA410 | COLD START 60A(t =375 s measured at 50% I ) at 230VAC; width peak Per NEMA410 | COLD START 60A(t =375 s measured at 50% I ) at 230VAC; width peak Per NEMA410 | |
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 5 units (circuit breaker of type B) / 9 units (circuit breaker of type C) at 230VAC | 5 units (circuit breaker of type B) / 9 units (circuit breaker of type C) at 230VAC | 5 units (circuit breaker of type B) / 9 units (circuit breaker of type C) at 230VAC | |
LEAKAGE CURRENT | <0.75mA/ 277VAC | <0.75mA/ 277VAC | <0.75mA/ 277VAC | |
Specs Sheet |