240W Constant Voltage + Constant Current LED Driver
icon-announcement

Application:

LED Lighting
LED Moving Sign

Features

 Wide input range 180 ~ 528VAC
 Constant Voltage + Constant current mode ouput
 Metal housing design with class 1 design
 Built-in active PFC function
 Class 2 power unit
 IP67 / IP65 design for indoor or outdoor installations
 Function options: output adjustable via potentiometer
 3 in 1 dimming (dim-to-off)
 Timer dimming
 Typical lifetime > 50000 hours
 5 year warranty

HVG-240 series

MODELHVG-240-24HVG-240-30HVG-240-36
OUTPUTDC VOLTAGE24V30V36V
CONSTANT CURRENT REGION12 ~ 24V15 ~ 30V18 ~ 36V
RATED CURRENT10A8A6.7A
RATED POWER240W240W241.2W
RIPPLE & NOISE (max.)150mVp-p 200mVp-p250mVp-p
VOLTAGEADJ. RANGE - Adjustable for A-Type only (via the built-in potentiometer)22.4 ~ 25.6V28 ~ 32V33.5 ~ 38.5V
CURRENT ADJ. RANGE - Adjustable for A-Type only (via the built-in potentiometer)5 ~ 10A4 ~ 8A3.3 ~ 6.7A
VOLTAGE TOLERANCE±1.0%±1.0%±1.0%
LINE REGULATION±0.5%±0.5% ±0.5%
LOAD REGULATION±0.5%±0.5%±0.5%
SETUP TIME500ms, 150ms /230VAC, 347VAC, 480VAC500ms, 150ms /230VAC, 347VAC, 480VAC500ms, 150ms /230VAC, 347VAC, 480VAC
HOLD UP TIME (Typ.)18ms/347VAC, 480VAC18ms/347VAC, 480VAC18ms/347VAC, 480VAC
INPUTVOLTAGE RANGE180 ~ 528VAC 254VDC ~ 747VDC180 ~ 528VAC 254VDC ~ 747VDC180 ~ 528VAC 254VDC ~ 747VDC
FREQUENCY RANGE47 ~ 63Hz47 ~ 63Hz47 ~ 63Hz
POWER FACTOR (Typ.)PF>=0.98/230VAC, PF>=0.97/277VAC, PF>=0.95/347VAC, PF>=0.93/480VAC @full loadPF>=0.98/230VAC, PF>=0.97/277VAC, PF>=0.95/347VAC, PF>=0.93/480VAC @full loadPF>=0.98/230VAC, PF>=0.97/277VAC, PF>=0.95/347VAC, PF>=0.93/480VAC @full load
TOTAL HARMONIC DISTORTIONTHD< 20%(@ load>=50%/230VAC, 277VAC, 347VAC, @ load>=60%/480VAC)THD< 20%(@ load>=50%/230VAC, 277VAC, 347VAC, @ load>=60%/480VAC)THD< 20%(@ load>=50%/230VAC, 277VAC, 347VAC, @ load>=60%/480VAC)
EFFICIENCY (Typ.)92.5%92.5%93%
AC CURRENT (Typ.)0.8A/ 347VAC 0.6A/ 480VAC0.8A/ 347VAC 0.6A/ 480VAC0.8A/ 347VAC 0.6A/ 480VAC
INRUSH CURRENT(Typ.)COLD START 50A(t =532 s measured at 50% I ) at 480VAC; width peak Per NEMA410COLD START 50A(t =532 s measured at 50% I ) at 480VAC; width peak Per NEMA410COLD START 50A(t =532 s measured at 50% I ) at 480VAC; width peak Per NEMA410
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
4unit(circuit breaker of type B) / 6units(circuit breaker of type C) at 480VAC4unit(circuit breaker of type B) / 6units(circuit breaker of type C) at 480VAC4unit(circuit breaker of type B) / 6units(circuit breaker of type C) at 480VAC
LEAKAGE CURRENT<0.75mA/ 480VAC<0.75mA/ 480VAC<0.75mA/ 480VAC
Specs Sheet
untitled-3Download PDF
untitled-3Download PDF
untitled-3Download PDF

HVG-240 series

MODELHVG-240-42HVG-240-48HVG-240-54
OUTPUTDC VOLTAGE42V48V54V
CONSTANT CURRENT REGION21 ~ 42V24 ~ 48V27 ~ 54V
RATED CURRENT5.7A5A4.5A
RATED POWER239.4W240W243W
RIPPLE & NOISE (max.)250mVp-p250mVp-p350mVp-p
VOLTAGEADJ. RANGE - Adjustable for A-Type only (via the built-in potentiometer)39 ~ 45V44.8 ~ 51.2V50 ~ 57V
CURRENT ADJ. RANGE - Adjustable for A-Type only (via the built-in potentiometer)2.85 ~ 5.7A2.5 ~ 5A2.25 ~ 4.5A
VOLTAGE TOLERANCE±1.0%±1.0%±1.0%
LINE REGULATION±0.5% ±0.5% ±0.5%
LOAD REGULATION±0.5%±0.5%±0.5%
SETUP TIME500ms, 150ms /230VAC, 347VAC, 480VAC500ms, 150ms /230VAC, 347VAC, 480VAC500ms, 150ms /230VAC, 347VAC, 480VAC
HOLD UP TIME (Typ.)18ms/347VAC, 480VAC18ms/347VAC, 480VAC18ms/347VAC, 480VAC
INPUTVOLTAGE RANGE180 ~ 528VAC 254VDC ~ 747VDC180 ~ 528VAC 254VDC ~ 747VDC180 ~ 528VAC 254VDC ~ 747VDC
FREQUENCY RANGE47 ~ 63Hz47 ~ 63Hz47 ~ 63Hz
POWER FACTOR (Typ.)PF>=0.98/230VAC, PF>=0.97/277VAC, PF>=0.95/347VAC, PF>=0.93/480VAC @full loadPF>=0.98/230VAC, PF>=0.97/277VAC, PF>=0.95/347VAC, PF>=0.93/480VAC @full loadPF>=0.98/230VAC, PF>=0.97/277VAC, PF>=0.95/347VAC, PF>=0.93/480VAC @full load
TOTAL HARMONIC DISTORTIONTHD< 20%(@ load>=50%/230VAC, 277VAC, 347VAC, @ load>=60%/480VAC)THD< 20%(@ load>=50%/230VAC, 277VAC, 347VAC, @ load>=60%/480VAC)THD< 20%(@ load>=50%/230VAC, 277VAC, 347VAC, @ load>=60%/480VAC)
EFFICIENCY (Typ.)93% 92.5%93%
AC CURRENT (Typ.)0.8A/ 347VAC 0.6A/ 480VAC0.8A/ 347VAC 0.6A/ 480VAC0.8A/ 347VAC 0.6A/ 480VAC
INRUSH CURRENT(Typ.)COLD START 50A(t =532 s measured at 50% I ) at 480VAC; width peak Per NEMA410COLD START 50A(t =532 s measured at 50% I ) at 480VAC; width peak Per NEMA410COLD START 50A(t =532 s measured at 50% I ) at 480VAC; width peak Per NEMA410COLD START 35A(t =790 s measured at 50% I ) at 480VAC; width peak Per NEMA410
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
4unit(circuit breaker of type B) / 6units(circuit breaker of type C) at 480VAC4 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 480VAC4 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 480VAC
LEAKAGE CURRENT<0.75mA/ 480VAC<0.75mA/ 480VAC<0.75mA/ 480VAC