HLG-240H series
240W Constant Voltage + Constant Current LED Driver
NRCS LOA APPROVED
|
|
Application:
Features
Constant Voltage + Constant current mode ouput
Metal housing design with class 1 design
IP67 / IP65 design for indoor or outdoor installations
Function options: output adjustable via potentiometer
3 in 1 dimming
Typical lifetime > 62000 hours
7 year warranty
HLG-240H series
MODEL | HLG-240H-12 | HLG-240H-15 | HLG-240H-20 | |
---|---|---|---|---|
OUTPUT | DC VOLTAGE | 12V | 15V | 20V |
CONSTANT CURRENT REGION | 6 ~12V | 7.5 ~ 15V | 10 ~ 20V | |
RATED CURRENT | 16A | 15A | 12A | |
RATED POWER | 192W | 225W | 240W | |
RIPPLE & NOISE (max.) | 150mVp-p | 150mVp-p | 150mVp-p | |
VOLTAGE ADJ. RANGE - Adjustable forA-Type only (via built-in potentiometer) | 11.2 ~ 12.8V | 14 ~ 16V | 18.6 ~ 21.4V | |
CURRENT ADJ. RANGE - Adjustable forA-Type only (via built-in potentiometer) | 8 ~ 16A | 7.5 ~ 15A | 6 ~ 12A | |
VOLTAGE TOLERANCE | ±2.5% | ±2.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±2.0% | ±1.5% | ±1.0% | |
SET UP TIME | 1000ms,200ms/115VAC 500ms,200ms/230VAC | 1000ms,200ms/115VAC 500ms,200ms/230VAC | 1000ms,200ms/115VAC 500ms,200ms/230VAC | |
HOLD UP TIME (Typ.) | 15ms/ 115VAC, 230VAC | 15ms/ 115VAC, 230VAC | 15ms/ 115VAC, 230VAC | |
INPUT | VOLTAGE RANGE | 90 ~ 305VAC 127 ~ 431VDC | 90 ~ 305VAC 127 ~ 431VDC | 90 ~ 305VAC 127 ~ 431VDC |
FREQUENCY RANGE | 47 ~ 63Hz | 47 ~ 63Hz | 47 ~ 63Hz | |
POWER FACTOR (Typ.) | PF>=0.98/115VAC, PF >=0.95/230VAC @ full load | PF>=0.98/115VAC, PF >=0.95/230VAC @ full load | PF>=0.98/115VAC, PF >=0.95/230VAC @ full load | |
TOTAL HARMONIC DISTORTION | THD< 20% (@>=load 50% / 115VAC,230VAC; @ load>=75% / 277VAC) | THD< 20% (@>=load 50% / 115VAC,230VAC; @ load>=75% / 277VAC) | THD< 20% (@>=load 50% / 115VAC,230VAC; @ load>=75% / 277VAC) | |
EFFICIENCY (Typ.) | 90% | 90% | 91.5% | |
AC CURRENT (Typ.) | 4A/ 115VAC 2A/ 230VAC 1.2A/ 277VAC | 4A/ 115VAC 2A/ 230VAC 1.2A/ 277VAC | 4A/ 115VAC 2A/ 230VAC 1.2A/ 277VAC | |
INRUSH CURRENT(Typ.) | COLD START 75A(t =570 s measured at 50% I ) at 230VAC; width peak Per NEMA410 | COLD START 75A(t =570 s measured at 50% I ) at 230VAC; width peak Per NEMA410 | COLD START 75A(t =570 s measured at 50% I ) at 230VAC; width peak Per NEMA410 | |
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 2 units (circuit breaker of type B) / 4 units (circuit breaker of type C) at 230VAC | 2 units (circuit breaker of type B) / 4 units (circuit breaker of type C) at 230VAC | 2 units (circuit breaker of type B) / 4 units (circuit breaker of type C) at 230VAC | |
LEAKAGE CURRENT | <0.75mA/ 277VAC | <0.75mA/ 277VAC | <0.75mA/ 277VAC | |
Specs Sheet | ![]() | ![]() | ![]() |
HLG-240H series
MODEL | HLG-240H-24 | HLG-240H-30 | HLG-240H-36 | |
---|---|---|---|---|
OUTPUT | DC VOLTAGE | 24V | 30V | 36V |
CONSTANT CURRENT REGION | 12 ~ 24V | 15 ~ 30V | 18 ~ 36V | |
RATED CURRENT | 10A | 8A | 6.7A | |
RATED POWER | 240W | 240W | 241.2W | |
RIPPLE & NOISE (max.) | 150mVp-p | 200mVp-p | 250mVp-p | |
VOLTAGE ADJ. RANGE - Adjustable forA-Type only (via built-in potentiometer) | 22.4 ~ 25.6V | 28 ~ 32V | 33.5 ~ 38.5V | |
CURRENT ADJ. RANGE - Adjustable forA-Type only (via built-in potentiometer) | 5 ~ 10A | 4 ~ 8A | 3.3 ~ 6.7A | |
VOLTAGE TOLERANCE | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±0.5% | ±0.5% | ±0.5% | |
SET UP TIME | 1000ms,200ms/115VAC 500ms,200ms/230VAC | 1000ms,200ms/115VAC 500ms,200ms/230VAC | 1000ms,200ms/115VAC 500ms,200ms/230VAC | |
HOLD UP TIME (Typ.) | 15ms/ 115VAC, 230VAC | 15ms/ 115VAC, 230VAC | 15ms/ 115VAC, 230VAC | |
INPUT | VOLTAGE RANGE | 90 ~ 305VAC 127 ~ 431VDC | 90 ~ 305VAC 127 ~ 431VDC | 90 ~ 305VAC 127 ~ 431VDC |
FREQUENCY RANGE | 47 ~ 63Hz | 47 ~ 63Hz | 47 ~ 63Hz | |
POWER FACTOR (Typ.) | PF>=0.98/115VAC, PF >=0.95/230VAC @ full load | PF>=0.98/115VAC, PF >=0.95/230VAC @ full load | PF>=0.98/115VAC, PF >=0.95/230VAC @ full load | |
TOTAL HARMONIC DISTORTION | THD< 20% (@>=load 50% / 115VAC,230VAC; @ load>=75% / 277VAC) | THD< 20% (@>=load 50% / 115VAC,230VAC; @ load>=75% / 277VAC) | THD< 20% (@>=load 50% / 115VAC,230VAC; @ load>=75% / 277VAC) | |
EFFICIENCY (Typ.) | 92.5% | 92.5% | 92.5% | |
AC CURRENT (Typ.) | 4A/ 115VAC 2A/ 230VAC 1.2A/ 277VAC | 4A/ 115VAC 2A/ 230VAC 1.2A/ 277VAC | 4A/ 115VAC 2A/ 230VAC 1.2A/ 277VAC | |
INRUSH CURRENT(Typ.) | COLD START 75A(t =570 s measured at 50% I ) at 230VAC; width peak Per NEMA410 | COLD START 75A(t =570 s measured at 50% I ) at 230VAC; width peak Per NEMA410 | COLD START 75A(t =570 s measured at 50% I ) at 230VAC; width peak Per NEMA410 | |
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 2 units (circuit breaker of type B) / 4 units (circuit breaker of type C) at 230VAC | 2 units (circuit breaker of type B) / 4 units (circuit breaker of type C) at 230VAC | 2 units (circuit breaker of type B) / 4 units (circuit breaker of type C) at 230VAC | |
LEAKAGE CURRENT | <0.75mA/ 277VAC | <0.75mA/ 277VAC | <0.75mA/ 277VAC | |
Specs Sheet | ![]() | ![]() | ![]() |
HLG-240H series
MODEL | HLG-240H-42 | HLG-240H-48 | HLG-240H-54 | |
---|---|---|---|---|
OUTPUT | DC VOLTAGE | 42V | 48V | 54V |
CONSTANT CURRENT REGION | 21 ~ 42V | 24 ~ 48V | 27 ~ 54V | |
RATED CURRENT | 5.72A | 5A | 4.45A | |
RATED POWER | 240.24W | 240W | 240.3W | |
RIPPLE & NOISE (max.) | 250mVp-p | 250mVp-p | 350mVp-p | |
VOLTAGE ADJ. RANGE - Adjustable forA-Type only (via built-in potentiometer) | 39 ~ 45V | 44.8 ~ 51.2V | 50 ~ 57V | |
CURRENT ADJ. RANGE - Adjustable forA-Type only (via built-in potentiometer) | 2.86 ~ 5.72A | 2.5 ~ 5A | 2.23 ~ 4.45A | |
VOLTAGE TOLERANCE | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±0.5% | ±0.5% | ±0.5% | |
SET UP TIME | 1000ms,200ms/115VAC 500ms,200ms/230VAC | 1000ms,200ms/115VAC 500ms,200ms/230VAC | 1000ms,200ms/115VAC 500ms,200ms/230VAC | |
HOLD UP TIME (Typ.) | 15ms/ 115VAC, 230VAC | 15ms/ 115VAC, 230VAC | 15ms/ 115VAC, 230VAC | |
INPUT | VOLTAGE RANGE | 90 ~ 305VAC 127 ~ 431VDC | 90 ~ 305VAC 127 ~ 431VDC | 90 ~ 305VAC 127 ~ 431VDC |
FREQUENCY RANGE | 47 ~ 63Hz | 47 ~ 63Hz | 47 ~ 63Hz | |
POWER FACTOR (Typ.) | PF>=0.98/115VAC, PF >=0.95/230VAC @ full load | PF>=0.98/115VAC, PF >=0.95/230VAC @ full load | PF>=0.98/115VAC, PF >=0.95/230VAC @ full load | |
TOTAL HARMONIC DISTORTION | THD< 20% (@>=load 50% / 115VAC,230VAC; @ load>=75% / 277VAC) | THD< 20% (@>=load 50% / 115VAC,230VAC; @ load>=75% / 277VAC) | THD< 20% (@>=load 50% / 115VAC,230VAC; @ load>=75% / 277VAC) | |
EFFICIENCY (Typ.) | 92.5% | 93% | 93.5% | |
AC CURRENT (Typ.) | 4A/ 115VAC 2A/ 230VAC 1.2A/ 277VAC | 4A/ 115VAC 2A/ 230VAC 1.2A/ 277VAC | 4A/ 115VAC 2A/ 230VAC 1.2A/ 277VAC | |
INRUSH CURRENT(Typ.) | COLD START 75A(t =570 s measured at 50% I ) at 230VAC; width peak Per NEMA410 | COLD START 75A(t =570 s measured at 50% I ) at 230VAC; width peak Per NEMA410 | COLD START 75A(t =570 s measured at 50% I ) at 230VAC; width peak Per NEMA410 | |
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 2 units (circuit breaker of type B) / 4 units (circuit breaker of type C) at 230VAC | 2 units (circuit breaker of type B) / 4 units (circuit breaker of type C) at 230VAC | 2 units (circuit breaker of type B) / 4 units (circuit breaker of type C) at 230VAC | |
LEAKAGE CURRENT | <0.75mA/ 277VAC | <0.75mA/ 277VAC | <0.75mA/ 277VAC | |
Specs Sheet | ![]() | ![]() | ![]() |