HLP-80H Series
80W Single Output Switching Power Supply
buy online NOW
Application:
Features
* Universal AC input / Full range (up to 305VAC)
* Built-in active PFC function
* Protections: Short circuit / Over current / Over voltage / Over temperature
* Cooling by free air convection
* Output constant current level adjustable
* Class 2 power unit
* Three in one dimming function (1~10Vdc or PWM signal or resistance)
* Suitable for built in LED lighting system
* Suitable for dry / damp locations
* 100% full load burn-in test
* 3 years warranty
HLP-80H series
MODEL | HLP-80H-12 | HLP-80H-15 | HLP-80H-20 | |
---|---|---|---|---|
OUTPUT | DC VOLTAGE | 12V | 15V | 20V |
CONSTANT CURRENT REGION | 7.2 ~12V | 9 ~ 15V | 12 ~ 20V | |
RATED CURRENT | 5A | 5A | 4A | |
RATED POWER | 60W | 75W | 80W | |
RIPPLE & NOISE (max.) | 150mVp-p | 150mVp-p | 150mVp-p | |
VOLTAGE ADJ. RANGE | 10.8 ~ 13.5V | 13.5 ~ 17V | 17 ~ 22V | |
CURRENT ADJ. RANGE | 4 ~ 5A | 4 ~ 5A | 3.2 ~ 4A | |
VOLTAGE TOLERANCE | ±2.5% | ±2.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±2.0% | ±1.5% | ±1.0% | |
SETUP, RISE TIME | 1200ms,200ms/115VAC 500ms,200ms/230VAC at 95% load | 1200ms,200ms/115VAC 500ms,200ms/230VAC at 95% load | 1200ms,200ms/115VAC 500ms,200ms/230VAC at 95% load | |
HOLD UP TIME (Typ.) | 16ms at full load 230VAC /115VAC | 16ms at full load 230VAC /115VAC | 16ms at full load 230VAC /115VAC | |
INPUT | VOLTAGE RANGE | 90 ~ 305VAC 127 ~ 431VDC | 90 ~ 305VAC 127 ~ 431VDC | 90 ~ 305VAC 127 ~ 431VDC |
FREQUENCY RANGE | 47 ~ 63Hz | 47 ~ 63Hz | 47 ~ 63Hz | |
POWER FACTOR | PF>0.96/115VAC, PF>0.96/230VAC, PF>0.94/277VAC at full load | PF>0.96/115VAC, PF>0.96/230VAC, PF>0.94/277VAC at full load | PF>0.96/115VAC, PF>0.96/230VAC, PF>0.94/277VAC at full load | |
TOTALHARMONIC DISTORTION | THD< 20% when output loading>=60% at 115VAC/230VAC input and output loading>=75% at 277VAC input | THD< 20% when output loading>=60% at 115VAC/230VAC input and output loading>=75% at 277VAC input | THD< 20% when output loading>=60% at 115VAC/230VAC input and output loading>=75% at 277VAC input | |
EFFICIENCY (Typ.) | 87.5% | 88.5% | 89.5% | |
AC CURRENT | 0.85A/ 115VAC 0.425A/ 230VAC 0.4A/ 277VAC | 0.85A/ 115VAC 0.425A/ 230VAC 0.4A/ 277VAC | 0.85A/ 115VAC 0.425A/ 230VAC 0.4A/ 277VAC | |
INRUSH CURRENT(Typ.) | COLD START 70A(twidth=525 s measured at 50% Ipeak) at 230VAC | COLD START 70A(twidth=525 s measured at 50% Ipeak) at 230VAC | COLD START 70A(twidth=525 s measured at 50% Ipeak) at 230VAC | |
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 3 units (circuit breaker of type B) / 5 units (circuit breaker of type C) at 230VAC | 3 units (circuit breaker of type B) / 5 units (circuit breaker of type C) at 230VAC | 3 units (circuit breaker of type B) / 5 units (circuit breaker of type C) at 230VAC | |
LEAKAGE CURRENT | <0.75mA/ 277VAC | <0.75mA/ 277VAC | <0.75mA/ 277VAC | |
Specs Sheet |
HLP-80H series
MODEL | HLP-80H-24 | HLP-80H-30 | HLP-80H-36 | |
---|---|---|---|---|
OUTPUT | DC VOLTAGE | 24V | 30V | 36V |
CONSTANT CURRENT REGION | 14.4 ~ 24V | 18 ~ 30V | 21.6 ~ 36V | |
RATED CURRENT | 3.4A | 2.7A | 2.3A | |
RATED POWER | 81.6W | 81W | 82.8W | |
RIPPLE & NOISE (max.) | 150mVp-p | 200mVp-p | 200mVp-p | |
VOLTAGE ADJ. RANGE | 22 ~ 27V | 27 ~ 33V | 33 ~ 40V | |
CURRENT ADJ. RANGE | 2.72 ~ 3.4A | 2.16 ~ 2.7A | 1.84 ~ 2.3A | |
VOLTAGE TOLERANCE | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±0.5% | ±0.5% | ±0.5% | |
SETUP, RISE TIME | 1200ms,200ms/115VAC 500ms,200ms/230VAC at 95% load | 1200ms,200ms/115VAC 500ms,200ms/230VAC at 95% load | 1200ms,200ms/115VAC 500ms,200ms/230VAC at 95% load | |
HOLD UP TIME (Typ.) | 16ms at full load 230VAC /115VAC | 16ms at full load 230VAC /115VAC | 16ms at full load 230VAC /115VAC | |
INPUT | VOLTAGE RANGE | 90 ~ 305VAC 127 ~ 431VDC | 90 ~ 305VAC 127 ~ 431VDC | 90 ~ 305VAC 127 ~ 431VDC |
FREQUENCY RANGE | 47 ~ 63Hz | 47 ~ 63Hz | 47 ~ 63Hz | |
POWER FACTOR | PF>0.96/115VAC, PF>0.96/230VAC, PF>0.94/277VAC at full load | PF>0.96/115VAC, PF>0.96/230VAC, PF>0.94/277VAC at full load | PF>0.96/115VAC, PF>0.96/230VAC, PF>0.94/277VAC at full load | |
TOTALHARMONIC DISTORTION | THD< 20% when output loading>=60% at 115VAC/230VAC input and output loading>=75% at 277VAC input | THD< 20% when output loading>=60% at 115VAC/230VAC input and output loading>=75% at 277VAC input | THD< 20% when output loading>=60% at 115VAC/230VAC input and output loading>=75% at 277VAC input | |
EFFICIENCY (Typ.) | 90% | 90% | 90% | |
AC CURRENT | 0.85A/ 115VAC 0.425A/ 230VAC 0.4A/ 277VAC | 0.85A/ 115VAC 0.425A/ 230VAC 0.4A/ 277VAC | 0.85A/ 115VAC 0.425A/ 230VAC 0.4A/ 277VAC | |
INRUSH CURRENT(Typ.) | COLD START 70A(twidth=525 s measured at 50% Ipeak) at 230VAC | COLD START 70A(twidth=525 s measured at 50% Ipeak) at 230VAC | COLD START 70A(twidth=525 s measured at 50% Ipeak) at 230VAC | |
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 3 units (circuit breaker of type B) / 5 units (circuit breaker of type C) at 230VAC | 3 units (circuit breaker of type B) / 5 units (circuit breaker of type C) at 230VAC | 3 units (circuit breaker of type B) / 5 units (circuit breaker of type C) at 230VAC | |
LEAKAGE CURRENT | <0.75mA/ 277VAC | <0.75mA/ 277VAC | <0.75mA/ 277VAC | |
Specs Sheet |
HLP-80H series
MODEL | HLP-80H-42 | HLP-80H-48 | HLP-80H-54 | |
---|---|---|---|---|
OUTPUT | DC VOLTAGE | 42V | 48V | 54V |
CONSTANT CURRENT REGION | 25.2 ~ 42V | 28.8 ~ 48V | 32.4 ~ 54V | |
RATED CURRENT | 1.95A | 1.7A | 1.5A | |
RATED POWER | 81.9W | 81.6W | 81W | |
RIPPLE & NOISE (max.) | 200mVp-p | 200mVp-p | 200mVp-p | |
VOLTAGE ADJ. RANGE | 33 ~ 40V | 43 ~ 53V | 49 ~ 58V | |
CURRENT ADJ. RANGE | 1.56 ~ 1.95A | 1.36 ~ 1.7A | 1.2 ~ 1.5A | |
VOLTAGE TOLERANCE | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±0.5% | ±0.5% | ±0.5% | |
SETUP, RISE TIME | 1200ms,200ms/115VAC 500ms,200ms/230VAC at 95% load | 1200ms,200ms/115VAC 500ms,200ms/230VAC at 95% load | 1200ms,200ms/115VAC 500ms,200ms/230VAC at 95% load | |
HOLD UP TIME (Typ.) | 16ms at full load 230VAC /115VAC | 16ms at full load 230VAC /115VAC | 16ms at full load 230VAC /115VAC | |
INPUT | VOLTAGE RANGE | 90 ~ 305VAC 127 ~ 431VDC | 90 ~ 305VAC 127 ~ 431VDC | 90 ~ 305VAC 127 ~ 431VDC |
FREQUENCY RANGE | 47 ~ 63Hz | 47 ~ 63Hz | 47 ~ 63Hz | |
POWER FACTOR | PF>0.96/115VAC, PF>0.96/230VAC, PF>0.94/277VAC at full load | PF>0.96/115VAC, PF>0.96/230VAC, PF>0.94/277VAC at full load | PF>0.96/115VAC, PF>0.96/230VAC, PF>0.94/277VAC at full load | |
TOTALHARMONIC DISTORTION | THD< 20% when output loading>=60% at 115VAC/230VAC input and output loading>=75% at 277VAC input | THD< 20% when output loading>=60% at 115VAC/230VAC input and output loading>=75% at 277VAC input | THD< 20% when output loading>=60% at 115VAC/230VAC input and output loading>=75% at 277VAC input | |
EFFICIENCY (Typ.) | 90% | 90% | 90% | |
AC CURRENT | 0.85A/ 115VAC 0.425A/ 230VAC 0.4A/ 277VAC | 0.85A/ 115VAC 0.425A/ 230VAC 0.4A/ 277VAC | 0.85A/ 115VAC 0.425A/ 230VAC 0.4A/ 277VAC | |
INRUSH CURRENT(Typ.) | COLD START 70A(twidth=525 s measured at 50% Ipeak) at 230VAC | COLD START 70A(twidth=525 s measured at 50% Ipeak) at 230VAC | COLD START 70A(twidth=525 s measured at 50% Ipeak) at 230VAC | |
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 3 units (circuit breaker of type B) / 5 units (circuit breaker of type C) at 230VAC | 3 units (circuit breaker of type B) / 5 units (circuit breaker of type C) at 230VAC | 3 units (circuit breaker of type B) / 5 units (circuit breaker of type C) at 230VAC | |
LEAKAGE CURRENT | <0.75mA/ 277VAC | <0.75mA/ 277VAC | <0.75mA/ 277VAC | |
Specs Sheet |