OWA-60U series

60W Single Output Moistureproof Adaptor

 

Application:

Indoor LED lighting
LED Decorative Lighting
LED Office Lighting

Features

 Universal AC input/Full range(up tp 264VAC)
 High efficiency up to 91%
 Protections: Short circuit/ Overload / Over Voltage / Over Temperature
 Class II power unit, no FG
 Class II power unit
 Fully isolated plastic case
 Fanless design, cooling by free air convection
 No load power consumption < 0.15W
 Comply with EISA 2007 DoE and NRCan
 UL LISTED, suitable for dry and damp locations
 5 year warranty

OWA-60U series

MODELOWA-60U-12 OWA-60U-15OWA-60U-20
OUTPUTDC VOLTAGE12V15V20V
CONSTANT CURRENT REGION6 ~ 12V7.5 ~ 15V10 ~ 20V
RATED CURRENT5A4A3A
RATED POWER60W60W60W
RIPPLE & NOISE (max.) 150mVp-p150mVp-p150mVp-p
VOLTAGE TOLERANCE±4.0%±4.0%±4.0%
LINE REGULATION±1.0%±1.0%±1.0%
LOAD REGULATION±1.5%±1.0%±1.0%
SETUP TIME500ms, 80ms/230VAC 1000ms, 80ms/115VAC at 95% load500ms, 80ms/230VAC 1000ms, 80ms/115VAC at 95% load500ms, 80ms/230VAC 1000ms, 80ms/115VAC at 95% load
HOLD UP TIME (Typ.)10ms at full load 115VAC / 230VAC10ms at full load 115VAC / 230VAC10ms at full load 115VAC / 230VAC
INPUTVOLTAGE RANGE90 ~ 264VAC 127 ~ 370VDC90 ~ 264VAC 127 ~ 370VDC90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE47 ~ 63Hz47 ~ 63Hz47 ~ 63Hz
EFFICIENCY (Typ.) - 115VAC87%88% 88%
EFFICIENCY (Typ.) - 230VAC88% 89%89%
AC CURRENT1.2A / 115VAC 0.7A / 230VAC1.2A / 115VAC 0.7A / 230VAC1.2A / 115VAC 0.7A / 230VAC
INRUSH CURRENT(Typ.) - 35ACOLD START 35A(twidth=750 s measured at 50% Ipeak) at 115VACCOLD START 35A(twidth=750 s measured at 50% Ipeak) at 115VACCOLD START 35A(twidth=750 s measured at 50% Ipeak) at 115VAC
INRUSH CURRENT(Typ.) - 65ACOLD START 65A(twidth=750 s measured at 50% Ipeak) at 230VACCOLD START 65A(twidth=750 s measured at 50% Ipeak) at 230VACCOLD START 65A(twidth=750 s measured at 50% Ipeak) at 230VAC
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
2 units (circuit breaker of type B) / 4 units (circuit breaker of type C) at 230VAC2 units (circuit breaker of type B) / 4 units (circuit breaker of type C) at 230VAC2 units (circuit breaker of type B) / 4 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT<0.25mA / 240VAC<0.25mA / 240VAC<0.25mA / 240VAC
Specs Sheet
untitled-3Download PDF
untitled-3Download PDF
untitled-3Download PDF

OWA-60U series

MODELOWA-60U-24 OWA-60U-30OWA-60U-36
OUTPUTDC VOLTAGE24V30V36V
CONSTANT CURRENT REGION12 ~ 24V15 ~ 30V18 ~ 36V
RATED CURRENT2.5A2A1.67A
RATED POWER60W60W60.12W
RIPPLE & NOISE (max.) 150mVp-p200mVp-p200mVp-p
VOLTAGE TOLERANCE±3.0%±3.0% ±2.0%
LINE REGULATION±1.0%±1.0%±1.0%
LOAD REGULATION±1.0%±1.0% ±1.0%
SETUP TIME500ms, 80ms/230VAC 1000ms, 80ms/115VAC at 95% load500ms, 80ms/230VAC 1000ms, 80ms/115VAC at 95% load500ms, 80ms/230VAC 1000ms, 80ms/115VAC at 95% load
HOLD UP TIME (Typ.)10ms at full load 115VAC / 230VAC10ms at full load 115VAC / 230VAC10ms at full load 115VAC / 230VAC
INPUTVOLTAGE RANGE90 ~ 264VAC 127 ~ 370VDC90 ~ 264VAC 127 ~ 370VDC90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE47 ~ 63Hz47 ~ 63Hz47 ~ 63Hz
EFFICIENCY (Typ.) - 115VAC88.5% 88.5% 88.5%
EFFICIENCY (Typ.) - 230VAC90%90%90%
AC CURRENT1.2A / 115VAC 0.7A / 230VAC1.2A / 115VAC 0.7A / 230VAC1.2A / 115VAC 0.7A / 230VAC
INRUSH CURRENT(Typ.) - 35ACOLD START 35A(twidth=750 s measured at 50% Ipeak) at 115VACCOLD START 35A(twidth=750 s measured at 50% Ipeak) at 115VACCOLD START 35A(twidth=750 s measured at 50% Ipeak) at 115VAC
INRUSH CURRENT(Typ.) - 65ACOLD START 65A(twidth=750 s measured at 50% Ipeak) at 230VACCOLD START 65A(twidth=750 s measured at 50% Ipeak) at 230VACCOLD START 65A(twidth=750 s measured at 50% Ipeak) at 230VAC
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
2 units (circuit breaker of type B) / 4 units (circuit breaker of type C) at 230VAC2 units (circuit breaker of type B) / 4 units (circuit breaker of type C) at 230VAC2 units (circuit breaker of type B) / 4 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT<0.25mA / 240VAC<0.25mA / 240VAC<0.25mA / 240VAC
Specs Sheet
untitled-3Download PDF
untitled-3Download PDF
untitled-3Download PDF

OWA-60U series

MODELOWA-60U-42 OWA-60U-48OWA-60U-54
OUTPUTDC VOLTAGE42V48V54V
CONSTANT CURRENT REGION21 ~ 42V24 ~ 48V 27 ~ 54V
RATED CURRENT1.5A 1.25A 1.12A
RATED POWER63W60W60.48W
RIPPLE & NOISE (max.) 250mVp-p250mVp-p350mVp-p
VOLTAGE TOLERANCE±1.0% ±1.0% ±1.0%
LINE REGULATION±1.0%±1.0%±1.0%
LOAD REGULATION±1.0%±1.0%±1.0%
SETUP TIME500ms, 80ms/230VAC 1000ms, 80ms/115VAC at 95% load500ms, 80ms/230VAC 1000ms, 80ms/115VAC at 95% load500ms, 80ms/230VAC 1000ms, 80ms/115VAC at 95% load
HOLD UP TIME (Typ.)10ms at full load 115VAC / 230VAC10ms at full load 115VAC / 230VAC10ms at full load 115VAC / 230VAC
INPUTVOLTAGE RANGE90 ~ 264VAC 127 ~ 370VDC90 ~ 264VAC 127 ~ 370VDC90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE47 ~ 63Hz47 ~ 63Hz47 ~ 63Hz
EFFICIENCY (Typ.) - 115VAC88.5%88.5% 89%
EFFICIENCY (Typ.) - 230VAC90%91%91%
AC CURRENT1.2A / 115VAC 0.7A / 230VAC1.2A / 115VAC 0.7A / 230VAC1.2A / 115VAC 0.7A / 230VAC
INRUSH CURRENT(Typ.) - 35ACOLD START 35A(twidth=750 s measured at 50% Ipeak) at 115VACCOLD START 35A(twidth=750 s measured at 50% Ipeak) at 115VACCOLD START 35A(twidth=750 s measured at 50% Ipeak) at 115VAC
INRUSH CURRENT(Typ.) - 65ACOLD START 65A(twidth=750 s measured at 50% Ipeak) at 230VACCOLD START 65A(twidth=750 s measured at 50% Ipeak) at 230VACCOLD START 65A(twidth=750 s measured at 50% Ipeak) at 230VAC
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
2 units (circuit breaker of type B) / 4 units (circuit breaker of type C) at 230VAC2 units (circuit breaker of type B) / 4 units (circuit breaker of type C) at 230VAC2 units (circuit breaker of type B) / 4 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT<0.25mA / 240VAC<0.25mA / 240VAC<0.25mA / 240VAC