APV-25 SERIES
25W Single Output Switching Power Supply
Application:
Features
Constant voltage design
Universal AC input / Full range
Withstand 300VAC Surge input for 5 seconds
Fully isolated plastic case
IP42 design
100% full load burn-in test
Low cost, high reliability
2 years warranty
APV-25 series
MODEL | APV-25-5 | APV-25-12 | APV-25-15 | APV-25-24 | APV-25-36 | |
---|---|---|---|---|---|---|
OUTPUT | DC VOLTAGE | 5V | 12V | 15V | 24V | 36V |
RATED CURRENT | 3.5A | 2.1A | 1.68A | 1.05A | 0.7A | |
CURRENT RANGE | 0 ~ 3.5A | 0 ~ 2.1A | 0 ~ 1.68A | 0 ~ 1.05A | 0 ~ 0.7A | |
RATED POWER | 17.5W | 25.2W | 25.2W | 25.2W | 25.2W | |
RIPPLE & NOISE (max.) Note.2 | 120mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | |
VOLTAGE TOLERANCE Note.3 | ±5.0% | ±5.0% | ±5.0% | ±5.0% | ±5.0% | |
LINE REGULATION | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
LOAD REGULATION | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% | |
SETUP, RISE TIME | 1500ms, 30ms / 230VAC 1500ms,30ms / 115VAC at full load | 1500ms, 30ms / 230VAC 1500ms,30ms / 115VAC at full load | 1500ms, 30ms / 230VAC 1500ms,30ms / 115VAC at full load | 1500ms, 30ms / 230VAC 1500ms,30ms / 115VAC at full load | 1500ms, 30ms / 230VAC 1500ms,30ms / 115VAC at full load | |
HOLD UP TIME (Typ.) | 20ms/230VAC at full load | 20ms/230VAC at full load | 20ms/230VAC at full load | 20ms/230VAC 15ms/115VAC at full load | 20ms/230VAC 15ms/115VAC at full load | |
INPUT | VOLTAGE RANGE | 90 ~ 264VAC 127 ~ 370VDC (Note.6) | 90 ~ 264VAC 127 ~ 370VDC (Note.6) | 90 ~ 264VAC 127 ~ 370VDC (Note.6) | 90 ~ 264VAC 127 ~ 370VDC | 90 ~ 264VAC 127 ~ 370VDC |
FREQUENCY RANGE | 47 ~ 63Hz | 47 ~ 63Hz | 47 ~ 63Hz | 47 ~ 63Hz | 47 ~ 63Hz | |
EFFICIENCY (Typ.) | 75.5% | 82% | 83% | 83% | 84% | |
AC CURRENT | 0.4A/230VAC 0.8A/115VAC | 0.4A/230VAC 0.8A/115VAC | 0.4A/230VAC 0.8A/115VAC | 0.4A/230VAC 0.8A/115VAC | 0.4A/230VAC 0.8A/115VAC | |
INRUSH CURRENT(Typ.) | COLD START 45A(twidth=310 s measured at 50% Ipeak) at 230VAC | COLD START 45A(twidth=310 s measured at 50% Ipeak) at 230VAC | COLD START 45A(twidth=310 s measured at 50% Ipeak) at 230VAC | COLD START 45A(twidth=310 s measured at 50% Ipeak) at 230VAC | COLD START 45A(twidth=310 s measured at 50% Ipeak) at 230VAC | |
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 9 units (circuit breaker of type B) / 15 units (circuit breaker of type C) at 230VAC | 9 units (circuit breaker of type B) / 15 units (circuit breaker of type C) at 230VAC | 9 units (circuit breaker of type B) / 15 units (circuit breaker of type C) at 230VAC | 9 units (circuit breaker of type B) / 15 units (circuit breaker of type C) at 230VAC | 9 units (circuit breaker of type B) / 15 units (circuit breaker of type C) at 230VAC | |
LEAKAGE CURRENT | 0.25mA/ 240VAC | 0.25mA/ 240VAC | 0.25mA / 240VAC | 0.25mA / 240VAC | 0.25mA/ 240VAC | |
Specs Sheet |