HLG-320H-C series

320W Constant Current Mode LED Driver

buy online NOW

NRCS LOA APPROVED

 

 

Application:

LED Lighting
LED Moving Sign

Features

 Constant current mode output
 Metal housing design with class 1 design
 Built-in active PFC function
 IP67 / IP65 design for indoor or outdoor installations
 Function options: output adjustable via potentiometer
 3 in 1 dimming
 Typical lifetime > 62000 hours
 7 year warranty

HLG-320H-C series

MODELHLG-320H-C700HLG-320H-C1050HLG-320H-C1400HLG-320H-C175
OUTPUTRATED CURRENT700mA1050mA1400mA1750mA
RATED POWER299.6W 320.25W320.6W320.25W
CONSTANT CURRENT REGION214 ~ 428V 152 ~ 305V 114 ~ 229V91 ~ 183V
OPEN CIRCUIT VOLTAGE (max.) 435V311V234V187V
CURRENT ADJ. RANGE350 ~ 700mA 525 ~ 1050mA 700 ~ 1400mA 875 ~ 1750mA
CURRENT RIPPLE5.0% max. @rated current5.0% max. @rated current5.0% max. @rated current5.0% max. @rated current
CURRENT TOLERANCE± 5%± 5%± 5%± 5%
SET UP TIME1000ms/115VAC, or 500ms/230VAC1000ms/115VAC, or 500ms/230VAC1000ms/115VAC, or 500ms/230VAC1000ms/115VAC, or 500ms/230VAC
INPUTVOLTAGE RANGE90 ~ 305VAC 127 ~ 431VDC90 ~ 305VAC 127 ~ 431VDC90 ~ 305VAC 127 ~ 431VDC90 ~ 305VAC 127 ~ 431VDC
FREQUENCY RANGE47 ~ 63Hz47 ~ 63Hz47 ~ 63Hz47 ~ 63Hz
POWER FACTOR (Typ.)PF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.92/277VAC @ full loadPF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.92/277VAC @ full loadPF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.92/277VAC @ full loadPF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.92/277VAC @ full load
TOTAL HARMONIC DISTORTIONTHD< 20% (@ load>=50% /115VAC, 230VAC; @ load>=70%/277VAC)THD< 20% (@ load>=50% /115VAC, 230VAC; @ load>=70%/277VAC)THD< 20% (@ load>=50% /115VAC, 230VAC; @ load>=70%/277VAC)THD< 20% (@ load>=50% /115VAC, 230VAC; @ load>=70%/277VAC)
EFFICIENCY (Typ.)94%94%94%94%
AC CURRENT (Typ.)3.5A/ 115VAC 1.65A/ 230VAC 1.45A/ 277VAC3.5A/ 115VAC 1.65A/ 230VAC 1.45A/ 277VAC3.5A/ 115VAC 1.65A/ 230VAC 1.45A/ 277VAC3.5A/ 115VAC 1.65A/ 230VAC 1.45A/ 277VAC
INRUSH CURRENT(Typ.)COLD START 70A(t =1200 s measured at 50% I ) at 230VAC; width peak Per NEMA410COLD START 70A(t =1200 s measured at 50% I ) at 230VAC; width peak Per NEMA410COLD START 70A(t =1200 s measured at 50% I ) at 230VAC; width peak Per NEMA410COLD START 70A(t =1200 s measured at 50% I ) at 230VAC; width peak Per NEMA410
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
2 units (circuit breaker of type B) / 3 units (circuit breaker of type C) at 230VAC2 units (circuit breaker of type B) / 3 units (circuit breaker of type C) at 230VAC2 units (circuit breaker of type B) / 3 units (circuit breaker of type C) at 230VAC2 units (circuit breaker of type B) / 3 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT<0.75mA/ 277VAC<0.75mA/ 277VAC<0.75mA/ 277VAC<0.75mA/ 277VAC
Specs Sheet
untitled-3Download PDF
untitled-3Download PDF
untitled-3Download PDF
untitled-3Download PDF

HLG-320H-C series

MODELHLG-320H-C2100HLG-320H-C2800HLG-320H-C3500
OUTPUTRATED CURRENT2100mA2800mA3500mA
RATED POWER319.2W319.2W 318.5W
CONSTANT CURRENT REGION76 ~ 152V57 ~ 114V 46 ~ 91V
OPEN CIRCUIT VOLTAGE (max.) 156V118V95V
CURRENT ADJ. RANGE1050 ~ 2100mA1400 ~ 2800mA1750 ~ 3500mA
CURRENT RIPPLE5.0% max. @rated current5.0% max. @rated current5.0% max. @rated current
CURRENT TOLERANCE± 5%± 5%± 5%
SET UP TIME1000ms/115VAC, or 500ms/230VAC1000ms/115VAC, or 500ms/230VAC1000ms/115VAC, or 500ms/230VAC
INPUTVOLTAGE RANGE90 ~ 305VAC 127 ~ 431VDC90 ~ 305VAC 127 ~ 431VDC90 ~ 305VAC 127 ~ 431VDC
FREQUENCY RANGE47 ~ 63Hz47 ~ 63Hz47 ~ 63Hz
POWER FACTOR (Typ.)PF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.92/277VAC @ full loadPF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.92/277VAC @ full loadPF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.92/277VAC @ full load
TOTAL HARMONIC DISTORTIONTHD< 20% (@ load>=50% /115VAC, 230VAC; @ load>=70%/277VAC)THD< 20% (@ load>=50% /115VAC, 230VAC; @ load>=70%/277VAC)THD< 20% (@ load>=50% /115VAC, 230VAC; @ load>=70%/277VAC)
EFFICIENCY (Typ.)94%94%94%
AC CURRENT (Typ.)3.5A/ 115VAC 1.65A/ 230VAC 1.45A/ 277VAC3.5A/ 115VAC 1.65A/ 230VAC 1.45A/ 277VAC3.5A/ 115VAC 1.65A/ 230VAC 1.45A/ 277VAC
INRUSH CURRENT(Typ.)COLD START 70A(t =1200 s measured at 50% I ) at 230VAC; width peak Per NEMA410COLD START 70A(t =1200 s measured at 50% I ) at 230VAC; width peak Per NEMA410COLD START 70A(t =1200 s measured at 50% I ) at 230VAC; width peak Per NEMA410
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
2 units (circuit breaker of type B) / 3 units (circuit breaker of type C) at 230VAC2 units (circuit breaker of type B) / 3 units (circuit breaker of type C) at 230VAC2 units (circuit breaker of type B) / 3 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT<0.75mA/ 277VAC<0.75mA/ 277VAC<0.75mA/ 277VAC
Specs Sheet