LPF-25 series
25W Constant Voltage + Constant Current LED Driver
NRCS LOA APPROVED
|
buy online NOW
Application:
Features
Constant Voltage + Constant Current mode output
Plastic housing with class 2 design
Built-in active PFC function
Class 2 power unit
Fully encapsulated with IP67 level
Typical lifetime > 50000 hours
5 years warranty
LPF-25 series
MODEL | LPF-25-12 | LPF-25-15 | LPF-25-20 | |
---|---|---|---|---|
OUTPUT | DC VOLTAGE | 12V | 15V | 20V |
CONSTANT CURRENT REGION | 6.6 ~12V | 8.25 ~ 15V | 11 ~ 20V | |
RATED CURRENT | 2.1A | 1.67A | 1.25A | |
RATED POWER | 25.2W | 25.05W | 25W | |
RIPPLE & NOISE | 150mVp-p | 150mVp-p | 150mVp-p | |
VOLTAGE TOLERANCE | ±4.0% | ±4.0% | ±4.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±2.0% | ±1.5% | ±1.0% | |
SETUP TIME | 1500ms, 80ms / 115VAC 500ms, 80ms / 230VAC | 1500ms, 80ms / 115VAC 500ms, 80ms / 230VAC | 1500ms, 80ms / 115VAC 500ms, 80ms / 230VAC | |
HOLD UP TIME (Typ.) | 16ms/115VAC 16ms/230VAC | 16ms/115VAC 16ms/230VAC | 16ms/115VAC 16ms/230VAC | |
INPUT | VOLTAGE RANGE | 90 ~ 305VAC 127 ~ 431VDC | 90 ~ 305VAC 127 ~ 431VDC | 90 ~ 305VAC 127 ~ 431VDC |
FREQUENCY RANGE | 47 ~ 63Hz | 47 ~ 63Hz | 47 ~ 63Hz | |
POWER FACTOR (Typ.) | PF 0.97/115VAC, PF 0.95/230VAC, PF 0.92/277VAC@full load | PF 0.97/115VAC, PF 0.95/230VAC, PF 0.92/277VAC@full load | PF 0.97/115VAC, PF 0.95/230VAC, PF 0.92/277VAC@full load | |
TOTAL HARMONIC DISTORTION | THD< 20%(@load 60%/115VC,230VAC; @load 75%/277VAC) | THD< 20%(@load 60%/115VC,230VAC; @load 75%/277VAC) | THD< 20%(@load 60%/115VC,230VAC; @load 75%/277VAC) | |
EFFICIENCY (Typ.) | 84% | 85% | 86% | |
AC CURRENT | 0.4A/ 115VAC 0.25A/ 230VAC 0.2A/277VAC | 0.4A/ 115VAC 0.25A/ 230VAC 0.2A/277VAC | 0.4A/ 115VAC 0.25A/ 230VAC 0.2A/277VAC | |
INRUSH CURRENT(Typ.) | COLD START 50A(twidth=200 s measured at 50% Ipeak) at 230VAC μ ; Per NEMA410 | COLD START 50A(twidth=200 s measured at 50% Ipeak) at 230VAC μ ; Per NEMA410 | COLD START 50A(twidth=200 s measured at 50% Ipeak) at 230VAC μ ; Per NEMA410 | |
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 12 units (circuit breaker of type B) / 21 units (circuit breaker of type C) at 230VAC | 12 units (circuit breaker of type B) / 21 units (circuit breaker of type C) at 230VAC | 12 units (circuit breaker of type B) / 21 units (circuit breaker of type C) at 230VAC | |
LEAKAGE CURRENT | <0.75mA/ 240VAC | <0.75mA/ 240VAC | <0.75mA/ 240VAC | |
Specs Sheet |
LPF-25 series
MODEL | LPF-25-24 | LPF-25-30 | LPF-25-36 | |
---|---|---|---|---|
OUTPUT | DC VOLTAGE | 24V | 30V | 36V |
CONSTANT CURRENT REGION | 13.2 ~ 24V | 16.5 ~ 30V | 19.8 ~ 36V | |
RATED CURRENT | 1.05A | 0.84A | 0.7A | |
RATED POWER | 25.2W | 25.2W | 25.2W | |
RIPPLE & NOISE | 150mVp-p | 200mVp-p | 250mVp-p | |
VOLTAGE TOLERANCE | ±4.0% | ±4.0% | ±4.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±0.5% | ±2.0% | ±1.5% | |
SETUP TIME | 1500ms, 80ms / 115VAC 500ms, 80ms / 230VAC | 1500ms, 80ms / 115VAC 500ms, 80ms / 230VAC | 1500ms, 80ms / 115VAC 500ms, 80ms / 230VAC | |
HOLD UP TIME (Typ.) | 16ms/115VAC 16ms/230VAC | 16ms/115VAC 16ms/230VAC | 16ms/115VAC 16ms/230VAC | |
INPUT | VOLTAGE RANGE | 90 ~ 305VAC 127 ~ 431VDC | 90 ~ 305VAC 127 ~ 431VDC | 90 ~ 305VAC 127 ~ 431VDC |
FREQUENCY RANGE | 47 ~ 63Hz | 47 ~ 63Hz | 47 ~ 63Hz | |
POWER FACTOR (Typ.) | PF 0.97/115VAC, PF 0.95/230VAC, PF 0.92/277VAC@full load | PF 0.97/115VAC, PF 0.95/230VAC, PF 0.92/277VAC@full load | PF 0.97/115VAC, PF 0.95/230VAC, PF 0.92/277VAC@full load | |
TOTAL HARMONIC DISTORTION | THD< 20%(@load 60%/115VC,230VAC; @load 75%/277VAC) | THD< 20%(@load 60%/115VC,230VAC; @load 75%/277VAC) | THD< 20%(@load 60%/115VC,230VAC; @load 75%/277VAC) | |
EFFICIENCY (Typ.) | 86% | 86% | 86% | |
AC CURRENT | 0.4A/ 115VAC 0.25A/ 230VAC 0.2A/277VAC | 0.4A/ 115VAC 0.25A/ 230VAC 0.2A/277VAC | 0.4A/ 115VAC 0.25A/ 230VAC 0.2A/277VAC | |
INRUSH CURRENT(Typ.) | COLD START 50A(twidth=200 s measured at 50% Ipeak) at 230VAC μ ; Per NEMA410 | COLD START 50A(twidth=200 s measured at 50% Ipeak) at 230VAC μ ; Per NEMA410 | COLD START 50A(twidth=200 s measured at 50% Ipeak) at 230VAC μ ; Per NEMA410 | |
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 12 units (circuit breaker of type B) / 21 units (circuit breaker of type C) at 230VAC | 12 units (circuit breaker of type B) / 21 units (circuit breaker of type C) at 230VAC | 12 units (circuit breaker of type B) / 21 units (circuit breaker of type C) at 230VAC | |
LEAKAGE CURRENT | <0.75mA/ 240VAC | <0.75mA/ 240VAC | <0.75mA/ 240VAC | |
Specs Sheet |
LPF-25 series
MODEL | LPF-25-42 | LPF-25-48 | LPF-25-54 | |
---|---|---|---|---|
OUTPUT | DC VOLTAGE | 42V | 48V | 54V |
CONSTANT CURRENT REGION | 23.1 ~ 42V | 26.4 ~ 48V | 29.7 ~ 54V | |
RATED CURRENT | 0.6A | 0.53A | 0.47A | |
RATED POWER | 25.2W | 25.44W | 25.38W | |
RIPPLE & NOISE | 250mVp-p | 250mVp-p | 350mVp-p | |
VOLTAGE TOLERANCE | ±4.0% | ±4.0% | ±4.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±1.0% | ±0.5% | ±0.5% | |
SETUP TIME | 1500ms, 80ms / 115VAC 500ms, 80ms / 230VAC | 1500ms, 80ms / 115VAC 500ms, 80ms / 230VAC | 1500ms, 80ms / 115VAC 500ms, 80ms / 230VAC | |
HOLD UP TIME (Typ.) | 16ms/115VAC 16ms/230VAC | 16ms/115VAC 16ms/230VAC | 16ms/115VAC 16ms/230VAC | |
INPUT | VOLTAGE RANGE | 90 ~ 305VAC 127 ~ 431VDC | 90 ~ 305VAC 127 ~ 431VDC | 90 ~ 305VAC 127 ~ 431VDC |
FREQUENCY RANGE | 47 ~ 63Hz | 47 ~ 63Hz | 47 ~ 63Hz | |
POWER FACTOR (Typ.) | PF 0.97/115VAC, PF 0.95/230VAC, PF 0.92/277VAC@full load | PF 0.97/115VAC, PF 0.95/230VAC, PF 0.92/277VAC@full load | PF 0.97/115VAC, PF 0.95/230VAC, PF 0.92/277VAC@full load | |
TOTAL HARMONIC DISTORTION | THD< 20%(@load 60%/115VC,230VAC; @load 75%/277VAC) | THD< 20%(@load 60%/115VC,230VAC; @load 75%/277VAC) | THD< 20%(@load 60%/115VC,230VAC; @load 75%/277VAC) | |
EFFICIENCY (Typ.) | 86% | 87% | 86.5% | |
AC CURRENT | 0.4A/ 115VAC 0.25A/ 230VAC 0.2A/277VAC | 0.4A/ 115VAC 0.25A/ 230VAC 0.2A/277VAC | 0.4A/ 115VAC 0.25A/ 230VAC 0.2A/277VAC | |
INRUSH CURRENT(Typ.) | COLD START 50A(twidth=200 s measured at 50% Ipeak) at 230VAC μ ; Per NEMA410 | COLD START 50A(twidth=200 s measured at 50% Ipeak) at 230VAC μ ; Per NEMA410 | COLD START 50A(twidth=200 s measured at 50% Ipeak) at 230VAC μ ; Per NEMA410 | |
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 12 units (circuit breaker of type B) / 21 units (circuit breaker of type C) at 230VAC | 12 units (circuit breaker of type B) / 21 units (circuit breaker of type C) at 230VAC | 12 units (circuit breaker of type B) / 21 units (circuit breaker of type C) at 230VAC | |
LEAKAGE CURRENT | <0.75mA/ 240VAC | <0.75mA/ 240VAC | <0.75mA/ 240VAC | |
Specs Sheet |