PLC-100 series
100W Single Output Switching Power Supply
NRCS LOA APPROVED
|
Application:
Features
Universal AC input / Fill range
High efficiency 88.5%
Protections: Short circuit/ Over current/ Over Voltage/ Over temperature
Cooling by free air convection
Built-in active PFC function
Class 2 power unit
Pass LPS
100% full load burn-in test
High reliability, low cost
Suitable for LED lighting and moving sign applications
Compliance to worldwide safety regulations for lighting
2 year warranty
PLC-100 series
MODEL | PLC-100-12 | PLC-100-15 | PLC-100-20 | PLC-100-24 | |
---|---|---|---|---|---|
OUTPUT | DC VOLTAGE | 12V | 15V | 20V | 24V |
CONSTANT CURRENT REGION | 9 ~ 12V | 11.25 ~ 15V | 15 ~ 20V | 16.8 ~24V | |
RATED CURRENT | 5A | 5A | 4.8A | 4A | |
CURRENT RANGE | 0 ~ 5A | 0 ~ 5A | 0 ~ 4.8A | 0 ~ 4A | |
RATED POWER | 60W | 75W | 96W | 96W | |
RIPPLE & NOISE (max.) | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | |
VOLTAGE ADJ. RANGE | 10.2 ~ 12V | 12.8 ~ 15V | 17 ~ 20V | 20.4 ~ 24V | |
CURRENT ADJ. RANGE | 3.75 ~ 5A | 3.75 ~ 5A | 3.6 ~ 4.8A | 3 ~ 4A | |
VOLTAGE TOLERANCE | ±3.0% | ±3.0% | ±3.0% | ±3.0% | |
LINE REGULATION | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
LOAD REGULATION | ±2.0% | ±2.0% | ±2.0% | ±2.0% | |
SETUP TIME | 500ms, 80ms/230VAC 1200ms, 80ms/115VAC at full load | 500ms, 80ms/230VAC 1200ms, 80ms/115VAC at full load | 500ms, 80ms/230VAC 1200ms, 80ms/115VAC at full load | 500ms, 80ms/230VAC 1200ms, 80ms/115VAC at full load | |
HOLD UP TIME (Typ.) | 60ms/230VAC 16ms/115VAC at full load | 60ms/230VAC 16ms/115VAC at full load | 60ms/230VAC 16ms/115VAC at full load | 60ms/230VAC 16ms/115VAC at full load | |
INPUT | VOLTAGE RANGE | 90 ~ 264VAC 127 ~ 370VDC | 90 ~ 264VAC 127 ~ 370VDC | 90 ~ 264VAC 127 ~ 370VDC | 90 ~ 264VAC 127 ~ 370VDC |
FREQUENCY RANGE | 47 ~ 63Hz | 47 ~ 63Hz | 47 ~ 63Hz | 47 ~ 63Hz | |
POWER FACTOR (Typ.) | PF>0.92/115VAC, PF>0.9/230VAC at full load | PF>0.92/115VAC, PF>0.9/230VAC at full load | PF>0.92/115VAC, PF>0.9/230VAC at full load | PF>0.92/115VAC, PF>0.9/230VAC at full load | |
TOTAL HARMONIC DISTORTION | THD< 20% when output loading 75% at 115VAC/230VAC input | THD< 20% when output loading 75% at 115VAC/230VAC input | THD< 20% when output loading 75% at 115VAC/230VAC input | THD< 20% when output loading 75% at 115VAC/230VAC input | |
EFFICIENCY (Typ.) | 85% | 86% | 87.5% | 87% | |
AC CURRENT | 0.8A/115VAC 0.4A/230VAC | 0.8A/115VAC 0.4A/230VAC | 0.8A/115VAC 0.4A/230VAC | 0.8A/115VAC 0.4A/230VAC | |
INRUSH CURRENT(Typ.) | COLD START 35A(twidth=35 s measured at 50% Ipeak) at 230VAC | COLD START 35A(twidth=35 s measured at 50% Ipeak) at 230VAC | COLD START 35A(twidth=35 s measured at 50% Ipeak) at 230VAC | COLD START 35A(twidth=35 s measured at 50% Ipeak) at 230VAC | |
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 32 units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 230VAC | 32 units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 230VAC | 32 units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 230VAC | 32 units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 230VAC | |
LEAKAGE CURRENT | <0.75mA/ 240VAC | <0.75mA/ 240VAC | <0.75mA/ 240VAC | <0.75mA/ 240VAC | |
Specs Sheet |
PLC-100 series
MODEL | PLC-100-27 | PLC-100-36 | PLC-100-48 | |
---|---|---|---|---|
OUTPUT | DC VOLTAGE | 27V | 36V | 48V |
CONSTANT CURRENT REGION | 20.25 ~ 27V | 27 ~ 36V | 36 ~ 48V | |
RATED CURRENT | 3.55A | 2.65A | 2A | |
CURRENT RANGE | 0 ~ 3.55A | 0 ~ 2.65A | 0 ~ 2A | |
RATED POWER | 95.85W | 95.4W | 96W | |
RIPPLE & NOISE (max.) | 150mVp-p | 150mVp-p | 200mVp-p | |
VOLTAGE ADJ. RANGE | 23 ~ 27V | 30.6 ~ 36V | 40.8 ~ 48V | |
CURRENT ADJ. RANGE | 2.6 ~ 3.55A | 2 ~ 2.65A | 1.5 ~ 2A | |
VOLTAGE TOLERANCE | ±3.0% | ±2.0% | ±2.0% | |
LINE REGULATION | ±1.0% | ±1.0% | ±1.0% | |
LOAD REGULATION | ±2.0% | ±2.0% | ±2.0% | |
SETUP TIME | 500ms, 80ms/230VAC 1200ms, 80ms/115VAC at full load | 500ms, 80ms/230VAC 1200ms, 80ms/115VAC at full load | 500ms, 80ms/230VAC 1200ms, 80ms/115VAC at full load | |
HOLD UP TIME (Typ.) | 60ms/230VAC 16ms/115VAC at full load | 60ms/230VAC 16ms/115VAC at full load | 60ms/230VAC 16ms/115VAC at full load | |
INPUT | VOLTAGE RANGE | 90 ~ 264VAC 127 ~ 370VDC | 90 ~ 264VAC 127 ~ 370VDC | 90 ~ 264VAC 127 ~ 370VDC |
FREQUENCY RANGE | 47 ~ 63Hz | 47 ~ 63Hz | 47 ~ 63Hz | |
POWER FACTOR (Typ.) | PF>0.92/115VAC, PF>0.9/230VAC at full load | PF>0.92/115VAC, PF>0.9/230VAC at full load | PF>0.92/115VAC, PF>0.9/230VAC at full load | |
TOTAL HARMONIC DISTORTION | THD< 20% when output loading 75% at 115VAC/230VAC input | THD< 20% when output loading 75% at 115VAC/230VAC input | THD< 20% when output loading 75% at 115VAC/230VAC input | |
EFFICIENCY (Typ.) | 88% | 88% | 88.5% | |
AC CURRENT | 0.8A/115VAC 0.4A/230VAC | 0.8A/115VAC 0.4A/230VAC | 0.8A/115VAC 0.4A/230VAC | |
INRUSH CURRENT(Typ.) | COLD START 35A(twidth=35 s measured at 50% Ipeak) at 230VAC | COLD START 35A(twidth=35 s measured at 50% Ipeak) at 230VAC | COLD START 35A(twidth=35 s measured at 50% Ipeak) at 230VAC | |
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 32 units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 230VAC | 32 units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 230VAC | 32 units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 230VAC | |
LEAKAGE CURRENT | <0.75mA/ 240VAC | <0.75mA/ 240VAC | <0.75mA/ 240VAC | |
Specs Sheet |