HVG-480 series

480W Constant Voltage + Constant Current LED Driver
icon-announcement

 

Features

 Wide input range 180 ~ 528VAC
 Constant Voltage + Constant current mode ouput
 Metal housing design with class 1 design
 Built-in active PFC function
 IP67 / IP65 design for indoor or outdoor installations
 Function options: output adjustable via potentiometer
 3 in 1 dimming (dim-to-off)
 Smart Timer dimming
 Typical lifetime > 50000 hours
 5 year warranty

HVG-480 series

MODELHVG-480-24HVG-480-30HVG-480-36
OUTPUTDC VOLTAGE24V30V36V
CONSTANT CURRENT REGION12 ~ 24V15 ~ 30V18 ~ 36V
RATED CURRENT20A16A13.3A
RATED POWER480W480W478.8W
RIPPLE & NOISE (max.)200mVp-p 200mVp-p 250mVp-p
VOLTAGE ADJ. RANGE - Adjustable for A-Type only (via the built-in potentiometer)20.4 ~ 25.2V25.5 ~ 31.5V 30.6 ~ 37.8V
CURRENT ADJ. RANGE - Adjustable for A-Type only (via the built-in potentiometer)10 ~ 20A8 ~ 16A6.6 ~ 13.3A
VOLTAGE TOLERANCE±1.0%±1.0%±1.0%
LINE REGULATION±0.5% ±0.5% ±0.5%
LOAD REGULATION±0.5%±0.5%±0.5%
SETUP TIME500ms, 100ms / 230VAC, 347VAC, 480VAC
HOLD UP TIME (Typ.)16ms / 347VAC, 480VAC
INPUTVOLTAGE RANGE180 ~ 528VAC 254VDC ~ 747VDC
FREQUENCY RANGE47 ~ 63Hz
POWER FACTOR (Typ.)PF ≧ 0.98/230VAC,
PF ≧ 0.98/277VAC,
PF ≧ 0.97/347VAC,
PF ≧ 0.95/480VAC @ full load
TOTAL HARMONIC DISTORTIONTHD< 20% (@ load ≧ 50% at 230VAC/277VAC/347VAC/480VAC input
EFFICIENCY (Typ.)94%94%94.5%
AC CURRENT (Typ.)1.52A/ 347VAC 1.15A/ 480VAC
INRUSH CURRENT(Typ.)COLD START 40A(t =1100 s measured at 50% I ) at 480VAC ; width peak Per NEMA410
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
4unit(circuit breaker of type B) / 6units(circuit breaker of type C) at 480VAC
LEAKAGE CURRENT<0.75mA/ 480VAC
Specs Sheet
untitled-3Download PDF

HVG-480 series

MODELHVG-480-42HVG-480-48HVG-480-54
OUTPUTDC VOLTAGE42V48V54V
CONSTANT CURRENT REGION21 ~ 42V24 ~ 48V27 ~ 54V
RATED CURRENT11.4A10A8.9A
RATED POWER478.8W480W480.6W
RIPPLE & NOISE (max.)250mVp-p250mVp-p350mVp-p
VOLTAGE ADJ. RANGE - Adjustable for A-Type only (via the built-in potentiometer)35.7 ~ 44.1V 40.8 ~ 50.4V45.9 ~ 56.7V
CURRENT ADJ. RANGE - Adjustable for A-Type only (via the built-in potentiometer)5.7 ~ 11.4A5 ~ 10A4.4 ~ 8.9A
VOLTAGE TOLERANCE±1.0%±1.0%±1.0%
LINE REGULATION±0.5% ±0.5% ±0.5%
LOAD REGULATION±0.5%±0.5%±0.5%
SETUP TIME500ms, 100ms / 230VAC, 347VAC, 480VAC
HOLD UP TIME (Typ.)16ms / 347VAC, 480VAC
INPUTVOLTAGE RANGE180 ~ 528VAC 254VDC ~ 747VDC
FREQUENCY RANGE47 ~ 63Hz
POWER FACTOR (Typ.)PF ≧ 0.98/230VAC,
PF ≧ 0.98/277VAC,
PF ≧ 0.97/347VAC,
PF ≧ 0.95/480VAC @ full load
TOTAL HARMONIC DISTORTIONTHD< 20% (@ load ≧ 50% at 230VAC/277VAC/347VAC/480VAC input
EFFICIENCY (Typ.)95%95%95%
AC CURRENT (Typ.)1.52A/ 347VAC 1.15A/ 480VAC1.1A/ 347VAC 0.8A/ 480VAC1.1A/ 347VAC 0.8A/ 480VAC
INRUSH CURRENT(Typ.)COLD START 40A(t =1100 s measured at 50% I ) at 480VAC ; width peak Per NEMA410
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
4unit(circuit breaker of type B) / 6units(circuit breaker of type C) at 480VAC
LEAKAGE CURRENT<0.75mA/ 480VAC