90W Constant Current Mode LED Driver

NRCS LOA APPROVED

 

 

Application:

LED decorative lighting
LED office lighting
Indoor LED lighting

Features

 Constant Current mode output
 Plastic housing with class 2 design
 Built-in active PFC function
 Class 2 power unit
 IP67 rating for indoor or outdoor installations
 Function: 3 in 1 dimming
 Typical lifetime > 50000 hours
 5 years warranty

LPF-90D series

MODELLPF-90D-15 LPF-90D-20 LPF-90D-24LPF-90D-30
OUTPUTDC VOLTAGE15V20V24V30V
RATED CURRENT5A4.5A 3.75A3A
RATED POWER75W90W90W90W
CONSTANT CURRENT REGION9 ~ 15V12 ~ 20V 14.4 ~ 24V 18 ~ 30V
CURRENT RIPPLE5.0% max. @rated current5.0% max. @rated current5.0% max. @rated current5.0% max. @rated current
CURRENT TOLERANCE±5.0%±5.0%±5.0%±5.0%
SETUP TIME1200ms, 200ms / 115VAC 500ms, 200ms / 230VAC1200ms, 200ms / 115VAC 500ms, 200ms / 230VAC1200ms, 200ms / 115VAC 500ms, 200ms / 230VAC1200ms, 200ms / 115VAC 500ms, 200ms / 230VAC
HOLD UP TIME (Typ.)16ms/230VAC 16ms/115VAC16ms/230VAC 16ms/115VAC16ms/230VAC 16ms/115VAC16ms/230VAC 16ms/115VAC
INPUTVOLTAGE RANGE90 ~ 305VAC 127 ~ 431VDC90 ~ 305VAC 127 ~ 431VDC90 ~ 305VAC 127 ~ 431VDC90 ~ 305VAC 127 ~ 431VDC
FREQUENCY RANGE47 ~ 63Hz47 ~ 63Hz47 ~ 63Hz47 ~ 63Hz
POWER FACTOR (Typ.)PF 0.97/115VAC, PF 0.96/230VAC, PF 0.95/277VAC@full loadPF 0.97/115VAC, PF 0.96/230VAC, PF 0.95/277VAC@full loadPF 0.97/115VAC, PF 0.96/230VAC, PF 0.95/277VAC@full loadPF 0.97/115VAC, PF 0.96/230VAC, PF 0.95/277VAC@full load
TOTAL HARMONIC DISTORTIONTHD< 20%(@load 60%/115VC,230VAC; @load 75%/277VAC)THD< 20%(@load 60%/115VC,230VAC; @load 75%/277VAC)THD< 20%(@load 60%/115VC,230VAC; @load 75%/277VAC)THD< 20%(@load 60%/115VC,230VAC; @load 75%/277VAC)
EFFICIENCY (Typ.)89%89.5% 90%90.5%
AC CURRENT0.95A/ 115VAC 0.5A/ 230VAC 0.4A/ 277VAC0.95A/ 115VAC 0.5A/ 230VAC 0.4A/ 277VAC0.95A/ 115VAC 0.5A/ 230VAC 0.4A/ 277VAC0.95A/ 115VAC 0.5A/ 230VAC 0.4A/ 277VAC
INRUSH CURRENT(Typ.)COLD START 70A(twidth= s measured at 50% Ipeak) at 230VAC 435μ ; Per NEMA410COLD START 70A(twidth= s measured at 50% Ipeak) at 230VAC 435μ ; Per NEMA410COLD START 70A(twidth= s measured at 50% Ipeak) at 230VAC 435μ ; Per NEMA410COLD START 70A(twidth= s measured at 50% Ipeak) at 230VAC 435μ ; Per NEMA410
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
4 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC4 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC4 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC4 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT<0.75mA/ 240VAC<0.75mA/ 240VAC<0.75mA/ 240VAC<0.75mA/ 240VAC
Specs Sheet
untitled-3Download PDF
untitled-3Download PDF
untitled-3Download PDF
untitled-3Download PDF

LPF-90D series

MODELLPF-90D-36 LPF-90D-42 LPF-90D-48LPF-90D-54
OUTPUTDC VOLTAGE36V42V48V54V
RATED CURRENT2.5A2.15A1.88A1.67A
RATED POWER90W90.3W90.24W90.18W
CONSTANT CURRENT REGION21.6 ~ 36V 25.2 ~ 42V28.8 ~ 48V 32.4 ~ 54V
CURRENT RIPPLE5.0% max. @rated current5.0% max. @rated current5.0% max. @rated current5.0% max. @rated current
CURRENT TOLERANCE±5.0%±5.0%±5.0%±5.0%
SETUP TIME1200ms, 200ms / 115VAC 500ms, 200ms / 230VAC1200ms, 200ms / 115VAC 500ms, 200ms / 230VAC1200ms, 200ms / 115VAC 500ms, 200ms / 230VAC1200ms, 200ms / 115VAC 500ms, 200ms / 230VAC
HOLD UP TIME (Typ.)16ms/230VAC 16ms/115VAC16ms/230VAC 16ms/115VAC16ms/230VAC 16ms/115VAC16ms/230VAC 16ms/115VAC
INPUTVOLTAGE RANGE90 ~ 305VAC 127 ~ 431VDC90 ~ 305VAC 127 ~ 431VDC90 ~ 305VAC 127 ~ 431VDC90 ~ 305VAC 127 ~ 431VDC
FREQUENCY RANGE47 ~ 63Hz47 ~ 63Hz47 ~ 63Hz47 ~ 63Hz
POWER FACTOR (Typ.)PF 0.97/115VAC, PF 0.96/230VAC, PF 0.95/277VAC@full loadPF 0.97/115VAC, PF 0.96/230VAC, PF 0.95/277VAC@full loadPF 0.97/115VAC, PF 0.96/230VAC, PF 0.95/277VAC@full loadPF 0.97/115VAC, PF 0.96/230VAC, PF 0.95/277VAC@full load
TOTAL HARMONIC DISTORTIONTHD< 20%(@load 60%/115VC,230VAC; @load 75%/277VAC)THD< 20%(@load 60%/115VC,230VAC; @load 75%/277VAC)THD< 20%(@load 60%/115VC,230VAC; @load 75%/277VAC)THD< 20%(@load 60%/115VC,230VAC; @load 75%/277VAC)
EFFICIENCY (Typ.)90.5% 90.5% 90.5% 90.5%
AC CURRENT0.95A/ 115VAC 0.5A/ 230VAC 0.4A/ 277VAC0.95A/ 115VAC 0.5A/ 230VAC 0.4A/ 277VAC0.95A/ 115VAC 0.5A/ 230VAC 0.4A/ 277VAC0.95A/ 115VAC 0.5A/ 230VAC 0.4A/ 277VAC
INRUSH CURRENT(Typ.)COLD START 70A(twidth= s measured at 50% Ipeak) at 230VAC 435μ ; Per NEMA410COLD START 70A(twidth= s measured at 50% Ipeak) at 230VAC 435μ ; Per NEMA410COLD START 70A(twidth= s measured at 50% Ipeak) at 230VAC 435μ ; Per NEMA410COLD START 70A(twidth= s measured at 50% Ipeak) at 230VAC 435μ ; Per NEMA410
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
4 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC4 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC4 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC4 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT<0.75mA/ 240VAC<0.75mA/ 240VAC<0.75mA/ 240VAC<0.75mA/ 240VAC