LCM-40 series
40W Multiple-Stage Constant Current Mode LED Driver
buy online NOW
NRCS LOA APPROVED
|
Application:
Features
Constant Current mode output with multiple levels selectable by dip switch
Plastic housing with class 2 design
Built-in active PFC function
Standby power consumption <0.5W
Functions: 3 in one dimming(dim to off)
Auxiliary DC output
Synchronization of up 10 units
Optional: Wireless LED driver with integrated EnOcean module
3 year warranty
LCM-40 series
MODEL | LCM-40 | LCM-40 | LCM-40 | |
---|---|---|---|---|
OUTPUT | CURRENT LEVEL(Current level selectable via DIP switch) | 350mA | 500mA | 600mA |
RATED POWER | 42W | 42W | 42W | |
DC VOLTAGE RANGE | 2 ~ 100V | 2 ~ 80V | 2 ~ 67V | |
OPEN CIRCUIT VOLTAGE | 110V | 110V | 110V | |
CURRENT RIPPLE | 5.0% max. @rated current | 5.0% max. @rated current | 5.0% max. @rated current | |
CURRENT TOLERANCE | ±5% | ±5% | ±5% | |
AUXILIARY DC OUTPUT | Nominal 12V(deviation 11.4~12.6V)@50mA for AUX-Type only | Nominal 12V(deviation 11.4~12.6V)@50mA for AUX-Type only | Nominal 12V(deviation 11.4~12.6V)@50mA for AUX-Type only | |
SETUP TIME | 500ms / 230VAC | 500ms / 230VAC | 500ms / 230VAC | |
INPUT | VOLTAGE RANGE | 180 ~ 295VAC 254 ~ 417VDC | 180 ~ 295VAC 254 ~ 417VDC | 180 ~ 295VAC 254 ~ 417VDC |
FREQUENCY RANGE | 47 ~ 63Hz | 47 ~ 63Hz | 47 ~ 63Hz | |
POWER FACTOR (Typ.) | PF 0.975/230VAC, PF 0.96/277VAC @full load | PF 0.975/230VAC, PF 0.96/277VAC @full load | PF 0.975/230VAC, PF 0.96/277VAC @full load | |
TOTAL HARMONIC DISTORTION | THD< 20%(@load>=75%) | THD< 20%(@load>=75%) | THD< 20%(@load>=75%) | |
EFFICIENCY (Typ.) | 91% | 91% | 91% | |
AC CURRENT | 0.23A/230VAC 0.2A/277VAC | 0.23A/230VAC 0.2A/277VAC | 0.23A/230VAC 0.2A/277VAC | |
INRUSH CURRENT(Typ.) | COLD START 20A(twidth=260 s measured at 50% Ipeak) at 230VAC μ ; Per NEMA410 | COLD START 20A(twidth=260 s measured at 50% Ipeak) at 230VAC μ ; Per NEMA410 | COLD START 20A(twidth=260 s measured at 50% Ipeak) at 230VAC μ ; Per NEMA410 | |
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 26 units (circuit breaker of type B) / 44 units (circuit breaker of type C) at 230VAC | 26 units (circuit breaker of type B) / 44 units (circuit breaker of type C) at 230VAC | 26 units (circuit breaker of type B) / 44 units (circuit breaker of type C) at 230VAC | |
LEAKAGE CURRENT | <0.5mA/ 240VAC | <0.5mA/ 240VAC | <0.5mA/ 240VAC | |
Specs Sheet |
LCM-40 series
MODEL | LCM-40 | LCM-40 | LCM-40 | |
---|---|---|---|---|
OUTPUT | CURRENT LEVEL(Current level selectable via DIP switch) | 700mA(default) | 900mA | 1050mA |
RATED POWER | 42W | 42W | 42W | |
DC VOLTAGE RANGE | 2 ~ 57V | 2 ~ 45V | 2 ~ 40V | |
OPEN CIRCUIT VOLTAGE | 65V | 65V | 65V | |
CURRENT RIPPLE | 5.0% max. @rated current | 5.0% max. @rated current | 5.0% max. @rated current | |
CURRENT TOLERANCE | ±5% | ±5% | ±5% | |
AUXILIARY DC OUTPUT | Nominal 12V(deviation 11.4~12.6V)@50mA for AUX-Type only | Nominal 12V(deviation 11.4~12.6V)@50mA for AUX-Type only | Nominal 12V(deviation 11.4~12.6V)@50mA for AUX-Type only | |
SETUP TIME | 500ms / 230VAC | 500ms / 230VAC | 500ms / 230VAC | |
INPUT | VOLTAGE RANGE | 180 ~ 295VAC 254 ~ 417VDC | 180 ~ 295VAC 254 ~ 417VDC | 180 ~ 295VAC 254 ~ 417VDC |
FREQUENCY RANGE | 47 ~ 63Hz | 47 ~ 63Hz | 47 ~ 63Hz | |
POWER FACTOR (Typ.) | PF 0.975/230VAC, PF 0.96/277VAC @full load | PF 0.975/230VAC, PF 0.96/277VAC @full load | PF 0.975/230VAC, PF 0.96/277VAC @full load | |
TOTAL HARMONIC DISTORTION | THD< 20%(@load>=75%) | THD< 20%(@load>=75%) | THD< 20%(@load>=75%) | |
EFFICIENCY (Typ.) | 91% | 91% | 91% | |
AC CURRENT | 0.23A/230VAC 0.2A/277VAC | 0.23A/230VAC 0.2A/277VAC | 0.23A/230VAC 0.2A/277VAC | |
INRUSH CURRENT(Typ.) | COLD START 20A(twidth=260 s measured at 50% Ipeak) at 230VAC μ ; Per NEMA410 | COLD START 20A(twidth=260 s measured at 50% Ipeak) at 230VAC μ ; Per NEMA410 | COLD START 20A(twidth=260 s measured at 50% Ipeak) at 230VAC μ ; Per NEMA410 | |
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 26 units (circuit breaker of type B) / 44 units (circuit breaker of type C) at 230VAC | 26 units (circuit breaker of type B) / 44 units (circuit breaker of type C) at 230VAC | 26 units (circuit breaker of type B) / 44 units (circuit breaker of type C) at 230VAC | |
LEAKAGE CURRENT | <0.5mA/ 240VAC | <0.5mA/ 240VAC | <0.5mA/ 240VAC | |
Specs Sheet |