PLC-30 series
30W Single Output LED Power Supply
NRCS LOA APPROVED
|
|
Application:
Features
Universal AC input/Full range
Adjustable output voltage and current level
Protections: Short circuit/ Over current / Over Voltage / Over temperature
Cooling by free air convection
Built-in constant current limiting circuit
Fully isolated plastic case with terminal block style of I/O
Built-in active PFC function, comply with EN61000-3-2 class C(Pin >=25W)
Class 2 power unit, no FG
Class 2 power unit
100% full load burn-in test
High reliability
Suitable for LED lighting and moving sign applications
Compliance to worldwide safety regulations for lighting
2 year warranty
PLC-30 series
MODEL | PLC-30-9 | PLC-30-12 | PLC-30-15 | PLC-30-20 | |
---|---|---|---|---|---|
OUTPUT | DC VOLTAGE | 9V | 12V | 15V | 20V |
CONSTANT CURRENT REGION | 6.3 ~ 9V | 8.4 ~ 12V | 10.5 ~ 15V | 14 ~ 20V | |
RATED CURRENT | 3.3A | 2.5A | 2A | 1.5A | |
CURRENT RANGE | 0 ~ 5A | 0 ~ 2.5A | 0 ~ 2A | 0 ~ 1.5A | |
RATED POWER | 29.7W | 30W | 30W | 30W | |
RIPPLE & NOISE (max.) | 2.6Vp-p | 2Vp-p | 2.6Vp-p | 2.6Vp-p | |
VOLTAGE ADJ. RANGE | 8.55 ~ 9.9V | 11.4 ~ 13.2V | 14.5 ~ 16.5V | 19 ~ 22V | |
CURRENT ADJ. RANGE | 2.475 ~ 3.399A | 1.875 ~ 2.575A | 1.5 ~ 2.06A | 1.125 ~ 1.545A | |
VOLTAGE TOLERANCE | ±10% | ±10% | ±10% | ±10% | |
LINE REGULATION | ±3.0% | ±3.0% | ±3.0% | ±3.0% | |
LOAD REGULATION | ±5.0% | ±5.0% | ±5.0% | ±5.0% | |
SETUP TIME | 500ms / 230VAC 3000ms / 115VAC at full load | 500ms / 230VAC 3000ms / 115VAC at full load | 500ms / 230VAC 3000ms / 115VAC at full load | 500ms / 230VAC 3000ms / 115VAC at full load | |
INPUT | VOLTAGE RANGE | 90 ~ 264VAC 127 ~ 370VDC | 90 ~ 264VAC 127 ~ 370VDC | 90 ~ 264VAC 127 ~ 370VDC | 90 ~ 264VAC 127 ~ 370VDC |
FREQUENCY RANGE | 47 ~ 63Hz | 47 ~ 63Hz | 47 ~ 63Hz | 47 ~ 63Hz | |
POWER FACTOR (Typ.) | PF>0.95/115VAC, PF>0.9/230VAC at full load | PF>0.95/115VAC, PF>0.9/230VAC at full load | PF>0.95/115VAC, PF>0.9/230VAC at full load | PF>0.95/115VAC, PF>0.9/230VAC at full load | |
TOTAL HARMONIC DISTORTION | THD< 20% when output loading>=70% at 115VAC/230VAC input | THD< 20% when output loading>=70% at 115VAC/230VAC input | THD< 20% when output loading>=70% at 115VAC/230VAC input | THD< 20% when output loading>=70% at 115VAC/230VAC input | |
EFFICIENCY (Typ.) | 80% | 82.5% | 83.5% | 87% | |
AC CURRENT | 0.4A/115VAC 0.2A/230VAC | 0.4A/115VAC 0.2A/230VAC | 0.4A/115VAC 0.2A/230VAC | 0.4A/115VAC 0.2A/230VAC | |
INRUSH CURRENT(Typ.) | COLD START 35A(twidth=25 s measured at 50% Ipeak) at 230VAC | COLD START 35A(twidth=25 s measured at 50% Ipeak) at 230VAC | COLD START 35A(twidth=25 s measured at 50% Ipeak) at 230VAC | COLD START 35A(twidth=25 s measured at 50% Ipeak) at 230VAC | |
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 64 units (circuit breaker of type B) / 64 units (circuit breaker of type C) at 230VAC | 64 units (circuit breaker of type B) / 64 units (circuit breaker of type C) at 230VAC | 64 units (circuit breaker of type B) / 64 units (circuit breaker of type C) at 230VAC | 64 units (circuit breaker of type B) / 64 units (circuit breaker of type C) at 230VAC | |
LEAKAGE CURRENT | <0.5mA/ 240VAC | <0.5mA/ 240VAC | <0.5mA/ 240VAC | <0.5mA/ 240VAC | |
Specs Sheet | ![]() | ![]() | ![]() | ![]() |
PLC-30 series
MODEL | PLC-30-24 | PLC-30-27 | PLC-30-36 | PLC-30-48 | |
---|---|---|---|---|---|
OUTPUT | DC VOLTAGE | 24V | 27V | 36V | 48V |
CONSTANT CURRENT REGION | 16.8 ~ 24V | 18.9 ~ 27V | 25.2 ~ 36V | 33.6 ~ 48V | |
RATED CURRENT | 1.25A | 1.12A | 0.84A | 0.63A | |
CURRENT RANGE | 0 ~ 1.25A | 0 ~ 1.12A | 0 ~ 0.84A | 0 ~ 0.63A | |
RATED POWER | 30W | 30.24W | 30.24W | 30.24W | |
RIPPLE & NOISE (max.) | 2.4Vp-p | 2.3Vp-p | 3.6Vp-p | 3.7Vp-p | |
VOLTAGE ADJ. RANGE | 22.8 ~ 26.4V | 25.65 ~ 29.7V | 34.2 ~ 39.6V | 45.6 ~ 52.8V | |
CURRENT ADJ. RANGE | 0.938 ~ 1.288A | 0.84 ~ 1.1536A | 0.63 ~ 0.865A | 0.473 ~ 0.649A | |
VOLTAGE TOLERANCE | ±10% | ±10% | ±10% | ±10% | |
LINE REGULATION | ±3.0% | ±3.0% | ±3.0% | ±3.0% | |
LOAD REGULATION | ±5.0% | ±5.0% | ±5.0% | ±5.0% | |
SETUP TIME | 500ms / 230VAC 3000ms / 115VAC at full load | 500ms / 230VAC 3000ms / 115VAC at full load | 500ms / 230VAC 3000ms / 115VAC at full load | 500ms / 230VAC 3000ms / 115VAC at full load | |
INPUT | VOLTAGE RANGE | 90 ~ 264VAC 127 ~ 370VDC | 90 ~ 264VAC 127 ~ 370VDC | 90 ~ 264VAC 127 ~ 370VDC | 90 ~ 264VAC 127 ~ 370VDC |
FREQUENCY RANGE | 47 ~ 63Hz | 47 ~ 63Hz | 47 ~ 63Hz | 47 ~ 63Hz | |
POWER FACTOR (Typ.) | PF>0.95/115VAC, PF>0.9/230VAC at full load | PF>0.95/115VAC, PF>0.9/230VAC at full load | PF>0.95/115VAC, PF>0.9/230VAC at full load | PF>0.95/115VAC, PF>0.9/230VAC at full load | |
TOTAL HARMONIC DISTORTION | THD< 20% when output loading>=70% at 115VAC/230VAC input | THD< 20% when output loading>=70% at 115VAC/230VAC input | THD< 20% when output loading>=70% at 115VAC/230VAC input | THD< 20% when output loading>=70% at 115VAC/230VAC input | |
EFFICIENCY (Typ.) | 84% | 84.5% | 85% | 85.5% | |
AC CURRENT | 0.4A/115VAC 0.2A/230VAC | 0.4A/115VAC 0.2A/230VAC | 0.4A/115VAC 0.2A/230VAC | 0.4A/115VAC 0.2A/230VAC | |
INRUSH CURRENT(Typ.) | COLD START 35A(twidth=25 s measured at 50% Ipeak) at 230VAC | COLD START 35A(twidth=25 s measured at 50% Ipeak) at 230VAC | COLD START 35A(twidth=25 s measured at 50% Ipeak) at 230VAC | COLD START 35A(twidth=25 s measured at 50% Ipeak) at 230VAC | |
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 64 units (circuit breaker of type B) / 64 units (circuit breaker of type C) at 230VAC | 64 units (circuit breaker of type B) / 64 units (circuit breaker of type C) at 230VAC | 64 units (circuit breaker of type B) / 64 units (circuit breaker of type C) at 230VAC | 64 units (circuit breaker of type B) / 64 units (circuit breaker of type C) at 230VAC | |
LEAKAGE CURRENT | <0.5mA/ 240VAC | <0.5mA/ 240VAC | <0.5mA/ 240VAC | <0.5mA/ 240VAC | |
Specs Sheet | ![]() | ![]() | ![]() | ![]() |