PLD-25 Series
25W Single Output LED Power Supply
NRCS LOA APPROVED
|
buy online NOW
Application:
Features
Universal AC input / Full range(up to 295VAC)
Built in active PFC function
Constant current design
Protections: Short circuit / OVer temperature
Cooling by free air convection
Fully isolated plastic case
IP42 design
Class 2 power unit, no FG
Class 2 power unit
Suitable for dry/damp locations
100% full load burn-in test
Low cost
High reliability
3 years warranty
PLD-25 series
MODEL | PLD-25-350 | PLD-25-700 | PLD-25-1050 | PLD-25-1400 | |
---|---|---|---|---|---|
OUTPUT | RATED CURRENT | 350mA | 700mA | 1050mA | 1400mA |
OPERATING VOLTAGE RANGE | 40 ~ 58V | 24 ~ 36V | 16 ~ 24V | 12 ~ 18V | |
CURRENT ACCURACY | ±5.0% | ±5.0% | ±5.0% | ±5.0% | |
RATED POWER | 20.3W | 25.2W | 25.2W | 25.2W | |
RIPPLE & NOISE (max.) | 4.6Vp-p | 2.7Vp-p | 2.2Vp-p | 2Vp-p | |
NO LOAD OUTPUT VOLTAGE | 60V | 50V | 35V | 25V | |
SETUP TIME | 500ms / 230VAC 2000ms / 115VAC at full load | 500ms / 230VAC 2000ms / 115VAC at full load | 500ms / 230VAC 2000ms / 115VAC at full load | 500ms / 230VAC 2000ms / 115VAC at full load | |
INPUT | VOLTAGE RANGE | 90 ~ 295VAC 127 ~ 417VDC | 90 ~ 295VAC 127 ~ 417VDC | 90 ~ 295VAC 127 ~ 417VDC | 90 ~ 295VAC 127 ~ 417VDC |
FREQUENCY RANGE | 47 ~ 63Hz | 47 ~ 63Hz | 47 ~ 63Hz | 47 ~ 63Hz | |
POWER FACTOR (Typ.) | PF>0.98/115VAC, PF>0.92/230VAC, PF>0.91/277VAC at full load | PF>0.98/115VAC, PF>0.92/230VAC, PF>0.91/277VAC at full load | PF>0.98/115VAC, PF>0.92/230VAC, PF>0.91/277VAC at full load | PF>0.98/115VAC, PF>0.92/230VAC, PF>0.91/277VAC at full load | |
TOTAL HARMONIC DISTORTION | THD< 20% when output loading 70% at 115VAC/230VAC input and output loading 80% at 277VAC input | THD< 20% when output loading 70% at 115VAC/230VAC input and output loading 80% at 277VAC input | THD< 20% when output loading 70% at 115VAC/230VAC input and output loading 80% at 277VAC input | THD< 20% when output loading 70% at 115VAC/230VAC input and output loading 80% at 277VAC input | |
EFFICIENCY (Typ.) | 85% | 86% | 85% | 84% | |
AC CURRENT | 0.6A/115VAC 0.3A/230VAC 0.2A/277VAC | 0.6A/115VAC 0.3A/230VAC 0.2A/277VAC | 0.6A/115VAC 0.3A/230VAC 0.2A/277VAC | 0.6A/115VAC 0.3A/230VAC 0.2A/277VAC | |
INRUSH CURRENT(Typ.) | COLD START 25A(twidth=75 s measured at 50% Ipeak) at 230VAC | COLD START 25A(twidth=75 s measured at 50% Ipeak) at 230VAC | COLD START 25A(twidth=75 s measured at 50% Ipeak) at 230VAC | COLD START 25A(twidth=75 s measured at 50% Ipeak) at 230VAC | |
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 72 units (circuit breaker of type B) / 80 units (circuit breaker of type C) at 230VAC | 72 units (circuit breaker of type B) / 80 units (circuit breaker of type C) at 230VAC | 72 units (circuit breaker of type B) / 80 units (circuit breaker of type C) at 230VAC | 72 units (circuit breaker of type B) / 80 units (circuit breaker of type C) at 230VAC | |
LEAKAGE CURRENT | <0.5mA/ 240VAC | <0.5mA/ 240VAC | <0.5mA/ 240VAC | <0.5mA/ 240VAC | |
Specs Sheet |