100W Single Output LED Power Supply

NRCS LOA APPROVED

 

 

Application:

LED decorative lighting
LED office lighting
Indoor LED lighting

Features

 Universal AC input / Fill range(up tp 295VAC)
 High efficiency 88.5%
 Protections: Short circuit/ Over current/ Over Voltage/ Over temperature
 Cooling by free air convection
 Fully isolated plastic case with IP64 level
 Built-in active PFC function
 Pass LPS
 Class 2 power unit
 100% full load burn-in test
 High reliability
 Suitable for LED lighting and moving sign applications
 Suitable for dry/damp locations
 Compliance to worldwide safety regulations for lighting
 2 year warranty

PLN-100 series

MODELPLN-100-12PLN-100-15 PLN-100-20 PLN-100-24
OUTPUTDC VOLTAGE12V15V20V24V
CONSTANT CURRENT REGION9 ~ 12V11.25 ~ 15V15 ~ 20V 18 ~ 24V
RATED CURRENT5A5A4.8A 4A
RATED POWER60W75W96W96W
RIPPLE & NOISE (max.)150mVp-p150mVp-p 150mVp-p150mVp-p
VOLTAGE ADJ. RANGE(Can be adjusted by internal potentiometer SVR1)10.2 ~ 12V12.8 ~ 15V17 ~ 20V20.4 ~ 24V
CURRENT ADJ. RANGE 3.75 ~ 5A3.75 ~ 5A3.6 ~ 4.8A3 ~ 4A
VOLTAGE TOLERANCE(Can be adjusted by internal potentiometer SVR2)±3.0%±3.0%±3.0%±3.0%
LINE REGULATION±1.0%±1.0%±1.0%±1.0%
LOAD REGULATION±2.0%±2.0%±2.0%±2.0%
SETUP TIME500ms, 80ms/230VAC 1200ms, 80ms/115VAC at full load500ms, 80ms/230VAC 1200ms, 80ms/115VAC at full load500ms, 80ms/230VAC 1200ms, 80ms/115VAC at full load500ms, 80ms/230VAC 1200ms, 80ms/115VAC at full load
INPUTVOLTAGE RANGE90 ~ 295VAC 127 ~ 417VDC90 ~ 295VAC 127 ~ 417VDC90 ~ 295VAC 127 ~ 417VDC90 ~ 295VAC 127 ~ 417VDC
FREQUENCY RANGE47 ~ 63Hz47 ~ 63Hz47 ~ 63Hz47 ~ 63Hz
POWER FACTOR (Typ.)PF>0.95/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full loadPF>0.95/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full loadPF>0.95/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full loadPF>0.95/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load
TOTAL HARMONIC DISTORTIONTHD< 20% when output loading 75% at 115VAC/230VAC input and output loading 75% at 277VAC inputTHD< 20% when output loading 75% at 115VAC/230VAC input and output loading 75% at 277VAC inputTHD< 20% when output loading 75% at 115VAC/230VAC input and output loading 75% at 277VAC inputTHD< 20% when output loading 75% at 115VAC/230VAC input and output loading 75% at 277VAC input
EFFICIENCY (Typ.)83%85%88.5%88.5%
AC CURRENT12V:0.8A/115VAC 0.4A/230VAC 0.3A/277VAC 15V:0.9A/115VAC 0.45A/230VAC 0.35A/277VAC
20V ~ 48V:1.1A/115VAC 0.55A/230VAC 0.45A/277VAC
12V:0.8A/115VAC 0.4A/230VAC 0.3A/277VAC 15V:0.9A/115VAC 0.45A/230VAC 0.35A/277VAC
20V ~ 48V:1.1A/115VAC 0.55A/230VAC 0.45A/277VAC
12V:0.8A/115VAC 0.4A/230VAC 0.3A/277VAC 15V:0.9A/115VAC 0.45A/230VAC 0.35A/277VAC
20V ~ 48V:1.1A/115VAC 0.55A/230VAC 0.45A/277VAC
12V:0.8A/115VAC 0.4A/230VAC 0.3A/277VAC 15V:0.9A/115VAC 0.45A/230VAC 0.35A/277VAC
20V ~ 48V:1.1A/115VAC 0.55A/230VAC 0.45A/277VAC
INRUSH CURRENT(Typ.)COLD START 40A(twidth=1030 s measured at 50% Ipeak) at 230VACCOLD START 40A(twidth=1030 s measured at 50% Ipeak) at 230VACCOLD START 40A(twidth=1030 s measured at 50% Ipeak) at 230VACCOLD START 40A(twidth=1030 s measured at 50% Ipeak) at 230VAC
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
3 units (circuit breaker of type B) / 5 units (circuit breaker of type C) at 230VAC3 units (circuit breaker of type B) / 5 units (circuit breaker of type C) at 230VAC3 units (circuit breaker of type B) / 5 units (circuit breaker of type C) at 230VAC3 units (circuit breaker of type B) / 5 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT<0.75mA/ 240VAC<0.75mA/ 240VAC<0.75mA/ 240VAC<0.75mA/ 240VAC
Specs Sheet
untitled-3Download PDF
untitled-3Download PDF
untitled-3Download PDF
untitled-3Download PDF

PLN-100 series

MODELPLN-100-27 PLN-100-36 PLN-100-48
OUTPUTDC VOLTAGE27V36V48V
CONSTANT CURRENT REGION20.25 ~ 27V 27 ~ 36V 36 ~ 48V
RATED CURRENT3.55A 2.65A 2A
RATED POWER95.85W 95.4W 96W
RIPPLE & NOISE (max.)150mVp-p150mVp-p200mVp-p
VOLTAGE ADJ. RANGE(Can be adjusted by internal potentiometer SVR1)23 ~ 27V30.6 ~ 36V40.8 ~ 48V
CURRENT ADJ. RANGE 2.6 ~ 3.55A2 ~ 2.65A1.5 ~ 2A
VOLTAGE TOLERANCE(Can be adjusted by internal potentiometer SVR2)±3.0%±2.0% ±2.0%
LINE REGULATION±1.0%±1.0%±1.0%
LOAD REGULATION±2.0%±2.0%±2.0%
SETUP TIME500ms, 80ms/230VAC 1200ms, 80ms/115VAC at full load500ms, 80ms/230VAC 1200ms, 80ms/115VAC at full load500ms, 80ms/230VAC 1200ms, 80ms/115VAC at full load
INPUTVOLTAGE RANGE90 ~ 295VAC 127 ~ 417VDC90 ~ 295VAC 127 ~ 417VDC90 ~ 295VAC 127 ~ 417VDC
FREQUENCY RANGE47 ~ 63Hz47 ~ 63Hz47 ~ 63Hz
POWER FACTOR (Typ.)PF>0.95/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full loadPF>0.95/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full loadPF>0.95/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load
TOTAL HARMONIC DISTORTIONTHD< 20% when output loading 75% at 115VAC/230VAC input and output loading 75% at 277VAC inputTHD< 20% when output loading 75% at 115VAC/230VAC input and output loading 75% at 277VAC inputTHD< 20% when output loading 75% at 115VAC/230VAC input and output loading 75% at 277VAC input
EFFICIENCY (Typ.)88% 88% 88.5%
AC CURRENT12V:0.8A/115VAC 0.4A/230VAC 0.3A/277VAC 15V:0.9A/115VAC 0.45A/230VAC 0.35A/277VAC
20V ~ 48V:1.1A/115VAC 0.55A/230VAC 0.45A/277VAC
12V:0.8A/115VAC 0.4A/230VAC 0.3A/277VAC 15V:0.9A/115VAC 0.45A/230VAC 0.35A/277VAC
20V ~ 48V:1.1A/115VAC 0.55A/230VAC 0.45A/277VAC
12V:0.8A/115VAC 0.4A/230VAC 0.3A/277VAC 15V:0.9A/115VAC 0.45A/230VAC 0.35A/277VAC
20V ~ 48V:1.1A/115VAC 0.55A/230VAC 0.45A/277VAC
INRUSH CURRENT(Typ.)COLD START 40A(twidth=1030 s measured at 50% Ipeak) at 230VACCOLD START 40A(twidth=1030 s measured at 50% Ipeak) at 230VACCOLD START 40A(twidth=1030 s measured at 50% Ipeak) at 230VAC
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
3 units (circuit breaker of type B) / 5 units (circuit breaker of type C) at 230VAC3 units (circuit breaker of type B) / 5 units (circuit breaker of type C) at 230VAC3 units (circuit breaker of type B) / 5 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT<0.75mA/ 240VAC<0.75mA/ 240VAC<0.75mA/ 240VAC
Specs Sheet
untitled-3Download PDF
untitled-3Download PDF
untitled-3Download PDF