HLG-480H series
480W Constant Voltage + Constant Current LED Driver
NRCS LOA APPROVED
|
Application:
Features
Constant Voltage + Constant current mode ouput
Metal housing design with class 1 design
Built-in active PFC function
IP67 / IP65 design for indoor or outdoor installations
Function options: output adjustable via potentiometer
3 in 1 dimming(dim-to-off, isolated design)
Smart Timer Dimming
Junction Box
Typical lifetime > 62000 hours
7 year warranty
HLG-480H series
MODEL | HLG-480H-24 | HLG-480H-30 | HLG-480H-36 | |
---|---|---|---|---|
OUTPUT | DC VOLTAGE | 24V | 30V | 36V |
CONSTANT CURRENT REGION | 12 ~ 24V | 15 ~ 30V | 18 ~ 36V | |
RATED CURRENT | 20A | 16A | 13.3A | |
RATED POWER | 480W | 480W | 478.8W | |
RIPPLE & NOISE (max.) | 200mVp-p | 200mVp-p | 250mVp-p | |
VOLTAGE ADJ. RANGE - Adjustable forA-Type only (via built-in potentiometer) | 20.4 ~ 25.2V | 25.5 ~ 31.5V | 30.6 ~ 37.8V | |
CURRENT ADJ. RANGE - Adjustable forA-Type only (via built-in potentiometer) | 10 ~ 20A | 8 ~ 16A | 6.6 ~ 13.3A | |
VOLTAGE TOLERANCE | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±0.5% | ±0.5% | ±0.5% | |
SET UP TIME | 500ms, 80ms 115VAC/230VAC | 500ms, 80ms 115VAC/230VAC | 500ms, 80ms 115VAC/230VAC | |
HOLD UP TIME (Typ.) | 16ms/ 115VAC, 230VAC | 16ms/ 115VAC, 230VAC | 16ms/ 115VAC, 230VAC | |
INPUT | VOLTAGE RANGE | 90 ~ 305VAC 127 ~ 431VDC | 90 ~ 305VAC 127 ~ 431VDC | 90 ~ 305VAC 127 ~ 431VDC |
FREQUENCY RANGE | 47 ~ 63Hz | 47 ~ 63Hz | 47 ~ 63Hz | |
POWER FACTOR (Typ.) | PF>=0.98/115VAC, PF>=0.97/230VAC, PF>=0.95/277VAC @ full load | PF>=0.98/115VAC, PF>=0.97/230VAC, PF>=0.95/277VAC @ full load | PF>=0.98/115VAC, PF>=0.97/230VAC, PF>=0.95/277VAC @ full load | |
TOTAL HARMONIC DISTORTION | THD< 20% (@ load>=40% / 115VAC,230VAC,277VAC) | THD< 20% (@ load>=40% / 115VAC,230VAC,277VAC) | THD< 20% (@ load>=40% / 115VAC,230VAC,277VAC) | |
EFFICIENCY (Typ.) (230Vac) | 94% | 94.5% | 95% | |
EFFICIENCY (Typ.) (277Vac) | 94.5% | 95% | 95.5% | |
AC CURRENT (Typ.) | 5A/ 115VAC 2.45A/ 230VAC 2A/ 277VAC | 5A/ 115VAC 2.45A/ 230VAC 2A/ 277VAC | 5A/ 115VAC 2.45A/ 230VAC 2A/ 277VAC | |
INRUSH CURRENT(Typ.) | COLD START 35A(t =1800 s measured at 50% I ) at 230VAC; Per NEMA410 | COLD START 35A(t =1800 s measured at 50% I ) at 230VAC; Per NEMA410 | COLD START 35A(t =1800 s measured at 50% I ) at 230VAC; Per NEMA410 | |
LEAKAGE CURRENT | <0.75mA/ 277VAC | <0.75mA/ 277VAC | <0.75mA/ 277VAC | |
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 2unit(circuit breaker of type B) / 3units(circuit breaker of type C) at 230VAC | 2unit(circuit breaker of type B) / 3units(circuit breaker of type C) at 230VAC | 2unit(circuit breaker of type B) / 3units(circuit breaker of type C) at 230VAC | |
Specs Sheet |
HLG-480H series
MODEL | HLG-480H-42 | HLG-480H-48 | HLG-480H-54 | |
---|---|---|---|---|
OUTPUT | DC VOLTAGE | 42V | 48V | 54V |
CONSTANT CURRENT REGION | 21 ~ 42V | 24 ~ 48V | 27 ~ 54V | |
RATED CURRENT | 11.4A | 10A | 8.9A | |
RATED POWER | 478.8W | 480W | 480.6W | |
RIPPLE & NOISE (max.) | 250mVp-p | 250mVp-p | 350mVp-p | |
VOLTAGE ADJ. RANGE - Adjustable forA-Type only (via built-in potentiometer) | 35.7 ~ 44.1V | 40.8 ~ 50.4V | 45.9 ~ 56.7V | |
CURRENT ADJ. RANGE - Adjustable forA-Type only (via built-in potentiometer) | 5.7 ~ 11.4A | 5 ~ 10A | 4.4 ~ 8.9A | |
VOLTAGE TOLERANCE | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±0.5% | ±0.5% | ±0.5% | |
SET UP TIME | 500ms, 80ms 115VAC/230VAC | 500ms, 80ms 115VAC/230VAC | 500ms, 80ms 115VAC/230VAC | |
HOLD UP TIME (Typ.) | 16ms/ 115VAC, 230VAC | 16ms/ 115VAC, 230VAC | 16ms/ 115VAC, 230VAC | |
INPUT | VOLTAGE RANGE | 90 ~ 305VAC 127 ~ 431VDC | 90 ~ 305VAC 127 ~ 431VDC | 90 ~ 305VAC 127 ~ 431VDC |
FREQUENCY RANGE | 47 ~ 63Hz | 47 ~ 63Hz | 47 ~ 63Hz | |
POWER FACTOR (Typ.) | PF>=0.98/115VAC, PF>=0.97/230VAC, PF>=0.95/277VAC @ full load | PF>=0.98/115VAC, PF>=0.97/230VAC, PF>=0.95/277VAC @ full load | PF>=0.98/115VAC, PF>=0.97/230VAC, PF>=0.95/277VAC @ full load | |
TOTAL HARMONIC DISTORTION | THD< 20% (@ load>=40% / 115VAC,230VAC,277VAC) | THD< 20% (@ load>=40% / 115VAC,230VAC,277VAC) | THD< 20% (@ load>=40% / 115VAC,230VAC,277VAC) | |
EFFICIENCY (Typ.) (230Vac) | 95% | 94.5% | 95% | |
EFFICIENCY (Typ.) (277Vac) | 95.5% | 95% | 95% | |
AC CURRENT (Typ.) | 5A/ 115VAC 2.45A/ 230VAC 2A/ 277VAC | 5A/ 115VAC 2.45A/ 230VAC 2A/ 277VAC | 5A/ 115VAC 2.45A/ 230VAC 2A/ 277VAC | |
INRUSH CURRENT(Typ.) | COLD START 35A(t =1800 s measured at 50% I ) at 230VAC; Per NEMA410 | COLD START 35A(t =1800 s measured at 50% I ) at 230VAC; Per NEMA410 | COLD START 35A(t =1800 s measured at 50% I ) at 230VAC; Per NEMA410 | |
LEAKAGE CURRENT | <0.75mA/ 277VAC | <0.75mA/ 277VAC | <0.75mA/ 277VAC | |
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 2unit(circuit breaker of type B) / 3units(circuit breaker of type C) at 230VAC | 2unit(circuit breaker of type B) / 3units(circuit breaker of type C) at 230VAC | 2unit(circuit breaker of type B) / 3units(circuit breaker of type C) at 230VAC | |
Specs Sheet |