PLN-20 series
20W Single Output LED Power Supply
NRCS LOA APPROVED
|
Application:
Features
Universal AC input / Fill range(up tp 277VAC)
Protections: Short circuit/ Over current/ Over Voltage/ Over temperature
Cooling by free air convection
Built-in constant current limiting circuit with adjustable OCP level
Fully isolated plastic case
Built-in active PFC function
IP64 design for indoor or outdoor installations
Small and compact size
Class 2 power unit, no FG
100% full load burn-in test
High reliability, low cost
Suitable for Dry/Damp locations
Suitable for LED lighting and moving sign applications
3 year warranty
PLN-20 series
MODEL | PLN-20-12 | PLN-20-18 | |
---|---|---|---|
OUTPUT | DC VOLTAGE | 12V | 18V |
CONSTANT CURRENT REGION | 9 ~ 12V | 13.5 ~ 18V | |
RATED CURRENT | 1.6A | 1.1A | |
CURRENT RANGE | 0 ~ 1.6A | 0 ~ 1.1A | |
CURRENTADJ. RANGE | 75% ~ 100% | 75% ~ 100% | |
RATED POWER | 19.2W | 19.8W | |
RIPPLE & NOISE (max.) | 2.5Vp-p | 3.0Vp-p | |
VOLTAGE TOLERANCE | ±10% | ±10% | |
LINE REGULATION | ±3.0% | ±3.0% | |
LOAD REGULATION | ±10% | ±10% | |
SETUP TIME | 500ms / 230VAC 2000ms / 115VAC at full load | 500ms / 230VAC 2000ms / 115VAC at full load | |
INPUT | VOLTAGE RANGE | 90 ~ 277VAC 127~392VDC | 90 ~ 277VAC 127~392VDC |
FREQUENCY RANGE | 47 ~ 63Hz | 47 ~ 63Hz | |
POWER FACTOR (Typ.) | PF 0.95/115VAC,PF>0.9/230VAC,PF>0.9/277VAC at full load | PF 0.95/115VAC,PF>0.9/230VAC,PF>0.9/277VAC at full load | |
TOTAL HARMONIC DISTORTION | THD< 20% when output loading 75% at 115VAC/230VAC input and output loading 75% at 277VAC input | THD< 20% when output loading 75% at 115VAC/230VAC input and output loading 75% at 277VAC input | |
EFFICIENCY (Typ.) | 80% | 81% | |
AC CURRENT | 0.4A/115VAC 0.2A/230VAC 0.15A/277VAC | 0.4A/115VAC 0.2A/230VAC 0.15A/277VAC | |
INRUSH CURRENT(Typ.) | COLD START 35A(twidth=40 s measured at 50% Ipeak) at 230VAC | COLD START 35A(twidth=40 s measured at 50% Ipeak) at 230VAC | |
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 98 units (circuit breaker of type B) / 98 units (circuit breaker of type C) at 230VAC | 98 units (circuit breaker of type B) / 98 units (circuit breaker of type C) at 230VAC | |
LEAKAGE CURRENT | 0.5mA/ 240VAC | 0.5mA/ 240VAC | |
Specs Sheet |
PLN-20 series
MODEL | PLN-20-24 | PLN-20-36 | |
---|---|---|---|
OUTPUT | DC VOLTAGE | 24V | 36V |
CONSTANT CURRENT REGION | 18 ~ 24V | 27 ~ 36V | |
RATED CURRENT | 0.8A | 0.55A | |
CURRENT RANGE | 0 ~ 0.8A | 0 ~ 0.55A | |
CURRENTADJ. RANGE | 75% ~ 100% | 75% ~ 100% | |
RATED POWER | 19.2W | 19.8W | |
RIPPLE & NOISE (max.) | 3.0Vp-p | 3.0Vp-p | |
VOLTAGE TOLERANCE | ±10% | ±10% | |
LINE REGULATION | ±3.0% | ±3.0% | |
LOAD REGULATION | ±10% | ±10% | |
SETUP TIME | 500ms / 230VAC 2000ms / 115VAC at full load | 500ms / 230VAC 2000ms / 115VAC at full load | |
INPUT | VOLTAGE RANGE | 90 ~ 277VAC 127~392VDC | 90 ~ 277VAC 127~392VDC |
FREQUENCY RANGE | 47 ~ 63Hz | 47 ~ 63Hz | |
POWER FACTOR (Typ.) | PF 0.95/115VAC,PF>0.9/230VAC,PF>0.9/277VAC at full load | PF 0.95/115VAC,PF>0.9/230VAC,PF>0.9/277VAC at full load | |
TOTAL HARMONIC DISTORTION | THD< 20% when output loading 75% at 115VAC/230VAC input and output loading 75% at 277VAC input | THD< 20% when output loading 75% at 115VAC/230VAC input and output loading 75% at 277VAC input | |
EFFICIENCY (Typ.) | 82% | 83% | |
AC CURRENT | 0.4A/115VAC 0.2A/230VAC 0.15A/277VAC | 0.4A/115VAC 0.2A/230VAC 0.15A/277VAC | |
INRUSH CURRENT(Typ.) | COLD START 35A(twidth=40 s measured at 50% Ipeak) at 230VAC | COLD START 35A(twidth=40 s measured at 50% Ipeak) at 230VAC | |
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 98 units (circuit breaker of type B) / 98 units (circuit breaker of type C) at 230VAC | 98 units (circuit breaker of type B) / 98 units (circuit breaker of type C) at 230VAC | |
LEAKAGE CURRENT | 0.5mA/ 240VAC | 0.5mA/ 240VAC | |
Specs Sheet |
PLN-20 series
MODEL | PLN-20-48 | |
---|---|---|
OUTPUT | DC VOLTAGE | 48V |
CONSTANT CURRENT REGION | 36 ~ 48V | |
RATED CURRENT | 0.42A | |
CURRENT RANGE | 0 ~ 0.42A | |
CURRENTADJ. RANGE | 75% ~ 100% | |
RATED POWER | 20.2W | |
RIPPLE & NOISE (max.) | 3.8Vp-p | |
VOLTAGE TOLERANCE | ±10% | |
LINE REGULATION | ±3.0% | |
LOAD REGULATION | ±10% | |
SETUP TIME | 500ms / 230VAC 2000ms / 115VAC at full load | |
INPUT | VOLTAGE RANGE | 90 ~ 277VAC 127~392VDC |
FREQUENCY RANGE | 47 ~ 63Hz | |
POWER FACTOR (Typ.) | PF 0.95/115VAC,PF>0.9/230VAC,PF>0.9/277VAC at full load | |
TOTAL HARMONIC DISTORTION | THD< 20% when output loading 75% at 115VAC/230VAC input and output loading 75% at 277VAC input | |
EFFICIENCY (Typ.) | 83.5% | |
AC CURRENT | 0.4A/115VAC 0.2A/230VAC 0.15A/277VAC | |
INRUSH CURRENT(Typ.) | COLD START 35A(twidth=40 s measured at 50% Ipeak) at 230VAC | |
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 98 units (circuit breaker of type B) / 98 units (circuit breaker of type C) at 230VAC | |
LEAKAGE CURRENT | 0.5mA/ 240VAC | |
Specs Sheet |