LCM-60UDA series

MODELLCM-60UDALCM-60UDALCM-60UDA
OUTPUTCURRENT LEVEL(Current level selectable via DIP switch)500mA600mA700mA(default)
RATED POWER50.4W50.4W50.4W
DC VOLTAGE RANGE2 ~ 90V 2 ~ 84V 2 ~ 72V
OPEN CIRCUIT VOLTAGE 102V102V102V
CURRENT RIPPLE5.0% max. @rated current5.0% max. @rated current5.0% max. @rated current
CURRENT TOLERANCE±5%±5%±5%
AUXILIARY DC OUTPUTNominal 12V(deviation 11.4~12.6V)@50mA for AUX-Type onlyNominal 12V(deviation 11.4~12.6V)@50mA for AUX-Type onlyNominal 12V(deviation 11.4~12.6V)@50mA for AUX-Type only
SETUP TIME1000ms / 115VAC1000ms / 115VAC1000ms / 115VAC
INPUTVOLTAGE RANGE 90 ~ 132VAC 127 ~ 186VDC90 ~ 132VAC 127 ~ 186VDC90 ~ 132VAC 127 ~ 186VDC
FREQUENCY RANGE47 ~ 63Hz47 ~ 63Hz47 ~ 63Hz
POWER FACTOR (Typ.)PF >= 0.98/115VAC @full loadPF >= 0.98/115VAC @full loadPF >= 0.98/115VAC @full load
TOTAL HARMONIC DISTORTIONTHD< 20%(@load>=60%)THD< 20%(@load>=60%)THD< 20%(@load>=60%)
EFFICIENCY (Typ.)89%89%89%
AC CURRENT0.65A/115VAC0.65A/115VAC0.65A/115VAC
INRUSH CURRENT(Typ.)COLD START 15A(t =270 s measured at 50% I ) at 115VAC width peak μ ; Per NEMA410COLD START 15A(t =270 s measured at 50% I ) at 115VAC width peak μ ; Per NEMA410COLD START 15A(t =270 s measured at 50% I ) at 115VAC width peak μ ; Per NEMA410
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
15 units (circuit breaker of type B) / 25 units (circuit breaker of type C) at 115VAC15 units (circuit breaker of type B) / 25 units (circuit breaker of type C) at 115VAC15 units (circuit breaker of type B) / 25 units (circuit breaker of type C) at 115VAC
LEAKAGE CURRENT<0.5mA/ 120VAC<0.5mA/ 120VAC<0.5mA/ 120VAC
Specs Sheet
untitled-3Download PDF
untitled-3Download PDF
untitled-3Download PDF

LCM-60UDA series

MODELLCM-60UDALCM-60UDALCM-60UDA
OUTPUTCURRENT LEVEL(Current level selectable via DIP switch)900mA1050mA1400mA
RATED POWER50.4W50.4W50.4W
DC VOLTAGE RANGE2 ~ 56V2 ~ 48V 2 ~ 36V
OPEN CIRCUIT VOLTAGE 76V102V76V
CURRENT RIPPLE5.0% max. @rated current5.0% max. @rated current5.0% max. @rated current
CURRENT TOLERANCE±5%±5%±5%
AUXILIARY DC OUTPUTNominal 12V(deviation 11.4~12.6V)@50mA for AUX-Type onlyNominal 12V(deviation 11.4~12.6V)@50mA for AUX-Type onlyNominal 12V(deviation 11.4~12.6V)@50mA for AUX-Type only
SETUP TIME1000ms / 115VAC1000ms / 115VAC1000ms / 115VAC
INPUTVOLTAGE RANGE 90 ~ 132VAC 127 ~ 186VDC90 ~ 132VAC 127 ~ 186VDC90 ~ 132VAC 127 ~ 186VDC
FREQUENCY RANGE47 ~ 63Hz47 ~ 63Hz47 ~ 63Hz
POWER FACTOR (Typ.)PF >= 0.98/115VAC @full loadPF >= 0.98/115VAC @full loadPF >= 0.98/115VAC @full load
TOTAL HARMONIC DISTORTIONTHD< 20%(@load>=60%)THD< 20%(@load>=60%)THD< 20%(@load>=60%)
EFFICIENCY (Typ.)89%89%89%
AC CURRENT0.65A/115VAC0.65A/115VAC0.65A/115VAC
INRUSH CURRENT(Typ.)COLD START 15A(t =270 s measured at 50% I ) at 115VAC width peak μ ; Per NEMA410COLD START 15A(t =270 s measured at 50% I ) at 115VAC width peak μ ; Per NEMA410COLD START 15A(t =270 s measured at 50% I ) at 115VAC width peak μ ; Per NEMA410
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
15 units (circuit breaker of type B) / 25 units (circuit breaker of type C) at 115VAC15 units (circuit breaker of type B) / 25 units (circuit breaker of type C) at 115VAC15 units (circuit breaker of type B) / 25 units (circuit breaker of type C) at 115VAC
LEAKAGE CURRENT<0.5mA/ 120VAC<0.5mA/ 120VAC<0.5mA/ 120VAC