LPF-16D series
16W Constant Current Mode LED Driver
Application:
Features
Constant Current mode output
Plastic housing with class 2 design
Built-in active PFC function
Class 2 power unit
Fully encapsulated with IP30 level, optional IP67 rating
Function: 3 in 1 dimming
Typical lifetime > 50000 hours
5 years warranty
LPF-16D series
MODEL | LPF-16D-12 | LPF-16D-15 | LPF-16D-20 | |
---|---|---|---|---|
OUTPUT | DC VOLTAGE | 12V | 15V | 20V |
RATED CURRENT | 1.34A | 1.07A | 0.8A | |
RATED POWER | 16.08W | 16.05W | 16W | |
CONSTANT CURRENT REGION | 6.6 ~12V | 8.25 ~ 15V | 11 ~ 20V | |
CURRENT RIPPLE | 5.0% max. @rated current | 5.0% max. @rated current | 5.0% max. @rated current | |
CURRENT TOLERANCE | ±5.0% | ±5.0% | ±5.0% | |
SETUP TIME | 1500ms, 80ms / 115VAC 500ms, 80ms / 230VAC | 1500ms, 80ms / 115VAC 500ms, 80ms / 230VAC | 1500ms, 80ms / 115VAC 500ms, 80ms / 230VAC | |
HOLD UP TIME (Typ.) | 16ms/230VAC 16ms/115VAC | 16ms/230VAC 16ms/115VAC | 16ms/230VAC 16ms/115VAC | |
INPUT | VOLTAGE RANGE | 90 ~ 305VAC 127 ~ 431VDC | 90 ~ 305VAC 127 ~ 431VDC | 90 ~ 305VAC 127 ~ 431VDC |
FREQUENCY RANGE | 47 ~ 63Hz | 47 ~ 63Hz | 47 ~ 63Hz | |
POWER FACTOR (Typ.) | PF 0.97/115VAC, PF 0.95/230VAC, PF 0.92/277VAC@full load | PF 0.97/115VAC, PF 0.95/230VAC, PF 0.92/277VAC@full load | PF 0.97/115VAC, PF 0.95/230VAC, PF 0.92/277VAC@full load | |
TOTAL HARMONIC DISTORTION | THD< 20%(@load 60%/115VC,230VAC; @load 75%/277VAC) | THD< 20%(@load 60%/115VC,230VAC; @load 75%/277VAC) | THD< 20%(@load 60%/115VC,230VAC; @load 75%/277VAC) | |
EFFICIENCY (Typ.) | 83% | 83% | 84.5% | |
AC CURRENT | 0.4A/ 115VAC 0.25A/ 230VAC 0.2A/277VAC | 0.4A/ 115VAC 0.25A/ 230VAC 0.2A/277VAC | 0.4A/ 115VAC 0.25A/ 230VAC 0.2A/277VAC | |
INRUSH CURRENT(Typ.) | COLD START 45A(twidth= s measured at 50% Ipeak) at 230VAC 200μ ; Per NEMA410 | COLD START 45A(twidth= s measured at 50% Ipeak) at 230VAC 200μ ; Per NEMA410 | COLD START 45A(twidth= s measured at 50% Ipeak) at 230VAC 200μ ; Per NEMA410 | |
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 14 units (circuit breaker of type B) / 24 units (circuit breaker of type C) at 230VAC | 14 units (circuit breaker of type B) / 24 units (circuit breaker of type C) at 230VAC | 14 units (circuit breaker of type B) / 24 units (circuit breaker of type C) at 230VAC | |
LEAKAGE CURRENT | <0.75mA/ 240VAC | <0.75mA/ 240VAC | <0.75mA/ 240VAC | |
Specs Sheet | ![]() | ![]() | ![]() |
LPF-16D series
MODEL | LPF-16D-24 | LPF-16D-30 | LPF-16D-36 | |
---|---|---|---|---|
OUTPUT | DC VOLTAGE | 24V | 30V | 36V |
RATED CURRENT | 0.67A | 0.54A | 0.45A | |
RATED POWER | 16.08W | 16.2W | 16.2W | |
CONSTANT CURRENT REGION | 13.2 ~ 24V | 16.5 ~ 30V | 19.8 ~ 36V | |
CURRENT RIPPLE | 5.0% max. @rated current | 5.0% max. @rated current | 5.0% max. @rated current | |
CURRENT TOLERANCE | ±5.0% | ±5.0% | ±5.0% | |
SETUP TIME | 1500ms, 80ms / 115VAC 500ms, 80ms / 230VAC | 1500ms, 80ms / 115VAC 500ms, 80ms / 230VAC | 1500ms, 80ms / 115VAC 500ms, 80ms / 230VAC | |
HOLD UP TIME (Typ.) | 16ms/230VAC 16ms/115VAC | 16ms/230VAC 16ms/115VAC | 16ms/230VAC 16ms/115VAC | |
INPUT | VOLTAGE RANGE | 90 ~ 305VAC 127 ~ 431VDC | 90 ~ 305VAC 127 ~ 431VDC | 90 ~ 305VAC 127 ~ 431VDC |
FREQUENCY RANGE | 47 ~ 63Hz | 47 ~ 63Hz | 47 ~ 63Hz | |
POWER FACTOR (Typ.) | PF 0.97/115VAC, PF 0.95/230VAC, PF 0.92/277VAC@full load | PF 0.97/115VAC, PF 0.95/230VAC, PF 0.92/277VAC@full load | PF 0.97/115VAC, PF 0.95/230VAC, PF 0.92/277VAC@full load | |
TOTAL HARMONIC DISTORTION | THD< 20%(@load 60%/115VC,230VAC; @load 75%/277VAC) | THD< 20%(@load 60%/115VC,230VAC; @load 75%/277VAC) | THD< 20%(@load 60%/115VC,230VAC; @load 75%/277VAC) | |
EFFICIENCY (Typ.) | 84.5% | 84.5% | 85% | |
AC CURRENT | 0.4A/ 115VAC 0.25A/ 230VAC 0.2A/277VAC | 0.4A/ 115VAC 0.25A/ 230VAC 0.2A/277VAC | 0.4A/ 115VAC 0.25A/ 230VAC 0.2A/277VAC | |
INRUSH CURRENT(Typ.) | COLD START 45A(twidth= s measured at 50% Ipeak) at 230VAC 200μ ; Per NEMA410 | COLD START 45A(twidth= s measured at 50% Ipeak) at 230VAC 200μ ; Per NEMA410 | COLD START 45A(twidth= s measured at 50% Ipeak) at 230VAC 200μ ; Per NEMA410 | |
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 14 units (circuit breaker of type B) / 24 units (circuit breaker of type C) at 230VAC | 14 units (circuit breaker of type B) / 24 units (circuit breaker of type C) at 230VAC | 14 units (circuit breaker of type B) / 24 units (circuit breaker of type C) at 230VAC | |
LEAKAGE CURRENT | <0.75mA/ 240VAC | <0.75mA/ 240VAC | <0.75mA/ 240VAC | |
Specs Sheet | ![]() | ![]() | ![]() |
LPF-16D series
MODEL | LPF-16D-42 | LPF-16D-48 | LPF-16D-54 | |
---|---|---|---|---|
OUTPUT | DC VOLTAGE | 42V | 48V | 54V |
RATED CURRENT | 0.39A | 0.34A | 0.3A | |
RATED POWER | 16.38W | 16.32W | 16.2W | |
CONSTANT CURRENT REGION | 23.1 ~ 42V | 26.4 ~ 48V | 29.7 ~ 54V | |
CURRENT RIPPLE | 5.0% max. @rated current | 5.0% max. @rated current | 5.0% max. @rated current | |
CURRENT TOLERANCE | ±5.0% | ±5.0% | ±5.0% | |
SETUP TIME | 1500ms, 80ms / 115VAC 500ms, 80ms / 230VAC | 1500ms, 80ms / 115VAC 500ms, 80ms / 230VAC | 1500ms, 80ms / 115VAC 500ms, 80ms / 230VAC | |
HOLD UP TIME (Typ.) | 16ms/230VAC 16ms/115VAC | 16ms/230VAC 16ms/115VAC | 16ms/230VAC 16ms/115VAC | |
INPUT | VOLTAGE RANGE | 90 ~ 305VAC 127 ~ 431VDC | 90 ~ 305VAC 127 ~ 431VDC | 90 ~ 305VAC 127 ~ 431VDC |
FREQUENCY RANGE | 47 ~ 63Hz | 47 ~ 63Hz | 47 ~ 63Hz | |
POWER FACTOR (Typ.) | PF 0.97/115VAC, PF 0.95/230VAC, PF 0.92/277VAC@full load | PF 0.97/115VAC, PF 0.95/230VAC, PF 0.92/277VAC@full load | PF 0.97/115VAC, PF 0.95/230VAC, PF 0.92/277VAC@full load | |
TOTAL HARMONIC DISTORTION | THD< 20%(@load 60%/115VC,230VAC; @load 75%/277VAC) | THD< 20%(@load 60%/115VC,230VAC; @load 75%/277VAC) | THD< 20%(@load 60%/115VC,230VAC; @load 75%/277VAC) | |
EFFICIENCY (Typ.) | 85% | 85% | 84.5% | |
AC CURRENT | 0.4A/ 115VAC 0.25A/ 230VAC 0.2A/277VAC | 0.4A/ 115VAC 0.25A/ 230VAC 0.2A/277VAC | 0.4A/ 115VAC 0.25A/ 230VAC 0.2A/277VAC | |
INRUSH CURRENT(Typ.) | COLD START 45A(twidth= s measured at 50% Ipeak) at 230VAC 200μ ; Per NEMA410 | COLD START 45A(twidth= s measured at 50% Ipeak) at 230VAC 200μ ; Per NEMA410 | COLD START 45A(twidth= s measured at 50% Ipeak) at 230VAC 200μ ; Per NEMA410 | |
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 14 units (circuit breaker of type B) / 24 units (circuit breaker of type C) at 230VAC | 14 units (circuit breaker of type B) / 24 units (circuit breaker of type C) at 230VAC | 14 units (circuit breaker of type B) / 24 units (circuit breaker of type C) at 230VAC | |
LEAKAGE CURRENT | <0.75mA/ 240VAC | <0.75mA/ 240VAC | <0.75mA/ 240VAC | |
Specs Sheet | ![]() | ![]() | ![]() |