PCD-16 series
16W Single OutputAC Dimmable LED Power Supply
NRCS LOA APPROVED
|
Application:
Features
AC phase-cut dimming
Work with leading edge and trailing edge TRIAC dimmers
115VAC or 230VAC models available
Built-in active PFC function
Constant current design
Protections: Short circuit / Over temperature
Cooling by free convection
Fully isolated plastic case
IP42 design
Class 2 power unit, no FG
Class 2 power unit
Suitable for indoor LED lighting applications
100% full load burn-in test
Low cost
High reliablity
3 years warranty
PCD-16 series
MODEL | PCD-16-350 | PCD-16-700 | PCD-16-1050 | PCD-16-1400 | |
---|---|---|---|---|---|
OUTPUT | RATED CURRENT | 350mA | 700mA | 1050mA | 1400mA |
OPERATING VOLTAGE RANGE | 24 ~ 48V | 16 ~ 24V | 12 ~ 16V | 8 ~ 12V | |
CURRENT ACCURACY | ±5.0% | ±5.0% | ±5.0% | ±5.0% | |
RATED POWER | 16.8W | 16.8W | 16.8W | 16.8W | |
RIPPLE & NOISE (max.) | 4.6Vp-p | 2.7Vp-p | 2.2Vp-p | 2Vp-p | |
NO LOAD OUTPUT VOLTAGE | 60V | 35V | 25V | 16V | |
SETUP TIME | 500ms / 230VAC 2000ms / 115VAC at full load | 500ms / 230VAC 2000ms / 115VAC at full load | 500ms / 230VAC 2000ms / 115VAC at full load | 500ms / 230VAC 2000ms / 115VAC at full load | |
INPUT | FREQUENCY RANGE | 47 ~ 63Hz | 47 ~ 63Hz | 47 ~ 63Hz | 47 ~ 63Hz |
POWER FACTOR (Typ.) | PF>0.9/115VAC, PF>0.9/230VAC, PF>0.9/277VAC at full load | PF>0.9/115VAC, PF>0.9/230VAC, PF>0.9/277VAC at full load | PF>0.9/115VAC, PF>0.9/230VAC, PF>0.9/277VAC at full load | PF>0.9/115VAC, PF>0.9/230VAC, PF>0.9/277VAC at full load | |
TOTAL HARMONIC DISTORTION - A Series | THD< 20% when output loading 70% at 115VAC | THD< 20% when output loading 70% at 115VAC | THD< 20% when output loading 70% at 115VAC | THD< 20% when output loading 70% at 115VAC | |
TOTAL HARMONIC DISTORTION - B Series | THD< 20% when output loading 70% at 230VAC input and output loading 80% at 277VAC input | THD< 20% when output loading 70% at 230VAC input and output loading 80% at 277VAC input | THD< 20% when output loading 70% at 230VAC input and output loading 80% at 277VAC input | THD< 20% when output loading 70% at 230VAC input and output loading 80% at 277VAC input | |
EFFICIENCY (Typ.) | 82% | 81% | 80.5% | 80% | |
AC CURRENT | 0.4A/115VAC 0.2A/230VAC 0.15A/277VAC | 0.4A/115VAC 0.2A/230VAC 0.15A/277VAC | 0.4A/115VAC 0.2A/230VAC 0.15A/277VAC | 0.4A/115VAC 0.2A/230VAC 0.15A/277VAC | |
INRUSH CURRENT(Typ.) | COLD START 10A(t =90 s measured at 50% I ) at 115VAC / 230VAC | COLD START 10A(t =90 s measured at 50% I ) at 115VAC / 230VAC | COLD START 10A(t =90 s measured at 50% I ) at 115VAC / 230VAC | COLD START 10A(t =90 s measured at 50% I ) at 115VAC / 230VAC | |
MAX. No. of PSUs on 16A CIRCUIT BREAKER - A Series | 58 units (circuit breaker of type B) / 58 units (circuit breaker of type C) at 115VAC | 58 units (circuit breaker of type B) / 58 units (circuit breaker of type C) at 115VAC | 58 units (circuit breaker of type B) / 58 units (circuit breaker of type C) at 115VAC | 58 units (circuit breaker of type B) / 58 units (circuit breaker of type C) at 115VAC | |
MAX. No. of PSUs on 16A CIRCUIT BREAKER - B Series | 128 units (circuit breaker of type B) / 128 units (circuit breaker of type C) at 230VAC | 128 units (circuit breaker of type B) / 128 units (circuit breaker of type C) at 230VAC | 128 units (circuit breaker of type B) / 128 units (circuit breaker of type C) at 230VAC | 128 units (circuit breaker of type B) / 128 units (circuit breaker of type C) at 230VAC | |
LEAKAGE CURRENT | <0.5mA/ 120VAC / 240VAC | <0.5mA/ 120VAC / 240VAC | <0.5mA/ 120VAC / 240VAC | <0.5mA/ 120VAC / 240VAC | |
Specs Sheet |