185W Constant Voltage + Constant Current LED Driver

buy online NOW

NRCS LOA APPROVED

 

 

Application:

LED Lighting
LED Moving Sign

Features

 Constant Voltage + Constant current mode ouput
 Metal housing design with class 1 design
 IP67 / IP65 design for indoor or outdoor installations
 Function options: output adjustable via potentiometer
 3 in 1 dimming
 Typical lifetime > 62000 hours
 7 year warranty

HLG-185H series

MODELHLG-185H-12HLG-185H-15HLG-185H-20
OUTPUTDC VOLTAGE12V15V20V
CONSTANT CURRENT REGION6 ~12V7.5 ~ 15V 10 ~ 20V
RATED CURRENT13A11.5A9.3A
RATED POWER156W172.5W 186W
RIPPLE & NOISE (max.)150mVp-p150mVp-p150mVp-p
VOLTAGE ADJ. RANGE - Adjustable forA-Type only (via built-in potentiometer)10.8 ~ 13.5V13.5 ~ 17V17 ~ 22V
CURRENT ADJ. RANGE - Adjustable forA-Type only (via built-in potentiometer)6.5 ~ 13A5.75 ~ 11.5A4.65 ~ 9.3A
VOLTAGE TOLERANCE±2.5%±2.0%±1.0%
LINE REGULATION±0.5%±0.5%±0.5%
LOAD REGULATION±2.0%±1.5% ±1.0%
SET UP TIME1000ms,200ms/115VAC 500ms,200ms/230VAC1000ms,200ms/115VAC 500ms,200ms/230VAC1000ms,200ms/115VAC 500ms,200ms/230VAC
HOLD UP TIME (Typ.)16ms / 115VAC, 230VAC16ms / 115VAC, 230VAC16ms / 115VAC, 230VAC
INPUTVOLTAGE RANGE90 ~ 305VAC 127 ~ 431VDC90 ~ 305VAC 127 ~ 431VDC90 ~ 305VAC 127 ~ 431VDC
FREQUENCY RANGE47 ~ 63Hz47 ~ 63Hz47 ~ 63Hz
POWER FACTOR (Typ.)PF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.92/277VAC @ full loadPF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.92/277VAC @ full loadPF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.92/277VAC @ full load
TOTAL HARMONIC DISTORTIONTHD< 20% (@>=load 50% / 115VAC,230VAC; @ load>=75% / 277VAC)THD< 20% (@>=load 50% / 115VAC,230VAC; @ load>=75% / 277VAC)THD< 20% (@>=load 50% / 115VAC,230VAC; @ load>=75% / 277VAC)
EFFICIENCY (Typ.)91.5% 92%93%
AC CURRENT (Typ.) - 12V1.8A/ 115VAC 0.8A/ 230VAC 0.7A/ 277VAC1.8A/ 115VAC 0.8A/ 230VAC 0.7A/ 277VAC1.8A/ 115VAC 0.8A/ 230VAC 0.7A/ 277VAC
AC CURRENT (Typ.) - 15V~54V2.1A/ 115VAC 0.9A/ 230VAC 0.8A/ 277VAC2.1A/ 115VAC 0.9A/ 230VAC 0.8A/ 277VAC2.1A/ 115VAC 0.9A/ 230VAC 0.8A/ 277VAC
INRUSH CURRENT(Typ.)COLD START 65A(t =445 s measured at 50% I ) at 230VAC; width peak Per NEMA410COLD START 65A(t =445 s measured at 50% I ) at 230VAC; width peak Per NEMA410COLD START 65A(t =445 s measured at 50% I ) at 230VAC; width peak Per NEMA410
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
4 units (circuit breaker of type B) / 7 units (circuit breaker of type C) at 230VAC4 units (circuit breaker of type B) / 7 units (circuit breaker of type C) at 230VAC4 units (circuit breaker of type B) / 7 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT<0.75mA/ 277VAC<0.75mA/ 277VAC<0.75mA/ 277VAC
Specs Sheet
untitled-3Download PDF
untitled-3Download PDF
untitled-3Download PDF

HLG-185H series

MODELHLG-185H-24HLG-185H-30HLG-185H-36
OUTPUTDC VOLTAGE24V30V36V
CONSTANT CURRENT REGION12 ~ 24V15 ~ 30V 18 ~ 36V
RATED CURRENT7.8A6.2A5.2A
RATED POWER187.2W186W187.2W
RIPPLE & NOISE (max.)150mVp-p200mVp-p200mVp-p
VOLTAGE ADJ. RANGE - Adjustable forA-Type only (via built-in potentiometer)22 ~ 27V27 ~ 33V33 ~ 40V
CURRENT ADJ. RANGE - Adjustable forA-Type only (via built-in potentiometer)3.9 ~ 7.8A3.1 ~ 6.2A2.6 ~ 5.2A
VOLTAGE TOLERANCE±1.0%±1.0%±1.0%
LINE REGULATION±0.5%±0.5%±0.5%
LOAD REGULATION±0.5%±0.5%±0.5%
SET UP TIME1000ms,200ms/115VAC 500ms,200ms/230VAC1000ms,200ms/115VAC 500ms,200ms/230VAC1000ms,200ms/115VAC 500ms,200ms/230VAC
HOLD UP TIME (Typ.)16ms / 115VAC, 230VAC16ms / 115VAC, 230VAC16ms / 115VAC, 230VAC
INPUTVOLTAGE RANGE90 ~ 305VAC 127 ~ 431VDC90 ~ 305VAC 127 ~ 431VDC90 ~ 305VAC 127 ~ 431VDC
FREQUENCY RANGE47 ~ 63Hz47 ~ 63Hz47 ~ 63Hz
POWER FACTOR (Typ.)PF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.92/277VAC @ full loadPF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.92/277VAC @ full loadPF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.92/277VAC @ full load
TOTAL HARMONIC DISTORTIONTHD< 20% (@>=load 50% / 115VAC,230VAC; @ load>=75% / 277VAC)THD< 20% (@>=load 50% / 115VAC,230VAC; @ load>=75% / 277VAC)THD< 20% (@>=load 50% / 115VAC,230VAC; @ load>=75% / 277VAC)
EFFICIENCY (Typ.)93.5%93.5%93.5%
AC CURRENT (Typ.) - 12V1.8A/ 115VAC 0.8A/ 230VAC 0.7A/ 277VAC1.8A/ 115VAC 0.8A/ 230VAC 0.7A/ 277VAC1.8A/ 115VAC 0.8A/ 230VAC 0.7A/ 277VAC
AC CURRENT (Typ.) - 15V~54V2.1A/ 115VAC 0.9A/ 230VAC 0.8A/ 277VAC2.1A/ 115VAC 0.9A/ 230VAC 0.8A/ 277VAC2.1A/ 115VAC 0.9A/ 230VAC 0.8A/ 277VAC
INRUSH CURRENT(Typ.)COLD START 65A(t =445 s measured at 50% I ) at 230VAC; width peak Per NEMA410COLD START 65A(t =445 s measured at 50% I ) at 230VAC; width peak Per NEMA410COLD START 65A(t =445 s measured at 50% I ) at 230VAC; width peak Per NEMA410
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
4 units (circuit breaker of type B) / 7 units (circuit breaker of type C) at 230VAC4 units (circuit breaker of type B) / 7 units (circuit breaker of type C) at 230VAC4 units (circuit breaker of type B) / 7 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT<0.75mA/ 277VAC<0.75mA/ 277VAC<0.75mA/ 277VAC
Specs Sheet
untitled-3Download PDF
untitled-3Download PDF
untitled-3Download PDF

HLG-185H series

MODELHLG-185H-42HLG-185H-48HLG-185H-54
OUTPUTDC VOLTAGE42V48V54V
CONSTANT CURRENT REGION21 ~ 42V24 ~ 48V27 ~ 54V
RATED CURRENT4.4A3.9A3.45A
RATED POWER184.8W187.2W186.3W
RIPPLE & NOISE (max.)300mVp-p300mVp-p300mVp-p
VOLTAGE ADJ. RANGE - Adjustable forA-Type only (via built-in potentiometer)40 ~ 46V44 ~ 53V49 ~ 58V
CURRENT ADJ. RANGE - Adjustable forA-Type only (via built-in potentiometer)2.2 ~ 4.4A1.95 ~ 3.9A1.72 ~ 3.45A
VOLTAGE TOLERANCE±1.0%±1.0%±1.0%
LINE REGULATION±0.5%±0.5%±0.5%
LOAD REGULATION±0.5%±0.5%±0.5%
SET UP TIME1000ms,200ms/115VAC 500ms,200ms/230VAC1000ms,200ms/115VAC 500ms,200ms/230VAC1000ms,200ms/115VAC 500ms,200ms/230VAC
HOLD UP TIME (Typ.)16ms / 115VAC, 230VAC16ms / 115VAC, 230VAC16ms / 115VAC, 230VAC
INPUTVOLTAGE RANGE90 ~ 305VAC 127 ~ 431VDC90 ~ 305VAC 127 ~ 431VDC90 ~ 305VAC 127 ~ 431VDC
FREQUENCY RANGE47 ~ 63Hz47 ~ 63Hz47 ~ 63Hz
POWER FACTOR (Typ.)PF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.92/277VAC @ full loadPF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.92/277VAC @ full loadPF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.92/277VAC @ full load
TOTAL HARMONIC DISTORTIONTHD< 20% (@>=load 50% / 115VAC,230VAC; @ load>=75% / 277VAC)THD< 20% (@>=load 50% / 115VAC,230VAC; @ load>=75% / 277VAC)THD< 20% (@>=load 50% / 115VAC,230VAC; @ load>=75% / 277VAC)
EFFICIENCY (Typ.)94%94%94%
AC CURRENT (Typ.) - 12V1.8A/ 115VAC 0.8A/ 230VAC 0.7A/ 277VAC1.8A/ 115VAC 0.8A/ 230VAC 0.7A/ 277VAC1.8A/ 115VAC 0.8A/ 230VAC 0.7A/ 277VAC
AC CURRENT (Typ.) - 15V~54V2.1A/ 115VAC 0.9A/ 230VAC 0.8A/ 277VAC2.1A/ 115VAC 0.9A/ 230VAC 0.8A/ 277VAC2.1A/ 115VAC 0.9A/ 230VAC 0.8A/ 277VAC
INRUSH CURRENT(Typ.)COLD START 65A(t =445 s measured at 50% I ) at 230VAC; width peak Per NEMA410COLD START 65A(t =445 s measured at 50% I ) at 230VAC; width peak Per NEMA410COLD START 65A(t =445 s measured at 50% I ) at 230VAC; width peak Per NEMA410
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
4 units (circuit breaker of type B) / 7 units (circuit breaker of type C) at 230VAC4 units (circuit breaker of type B) / 7 units (circuit breaker of type C) at 230VAC4 units (circuit breaker of type B) / 7 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT<0.75mA/ 277VAC<0.75mA/ 277VAC<0.75mA/ 277VAC