GSC25B series
25W Single Output LED Power Supply
Application:
Features
Universal AC input/Full range(up to 277VAC)
2 pole AC inlet IEC320-C8
Built-in active PFC function
Constant current design
Protections: Short circuit
Cooling by free air convection
Fully isolated plastic case
Class 2 power unit, no FG
No load power consumption <0.15W
Low cost, high reliability
100% full load burn-in test
3 year warranty
GSC25B series
MODEL | GSC25B-350 | GSC25B-500 | GSC25B-700 | GSC25B-1050 | GSC25B-1400 | |
---|---|---|---|---|---|---|
OUTPUT | RATED CURRENT | 350mA | 500mA | 700mA | 1050mA | 1400mA |
OPERATING VOLTAGE RANGE | 36 ~ 72V | 26 ~ 52V | 18 ~ 36V | 12 ~ 24V | 9 ~ 18V | |
CURRENT ACCURACY | ±8.0% | ±8.0% | ±8.0% | ±8.0% | ±8.0% | |
RATED POWER | 25.2W | 26W | 25.2W | 25.2W | 25.2W | |
RIPPLE & NOISE (max.) | 7.2Vp-p | 5Vp-p | 3.6Vp-p | 2.4Vp-p | 1.8Vp-p | |
NO LOAD OUTPUT VOLTAGE (max.) | 90V | 63V | 50V | 35V | 25V | |
SETUP TIME | 500ms / 230VAC 1000ms / 115VAC at full load | 500ms / 230VAC 1000ms / 115VAC at full load | 500ms / 230VAC 1000ms / 115VAC at full load | 500ms / 230VAC 1000ms / 115VAC at full load | 500ms / 230VAC 1000ms / 115VAC at full load | |
INPUT | VOLTAGE RANGE | 90 ~ 277VAC 127 ~ 392VDC | 90 ~ 277VAC 127 ~ 392VDC | 90 ~ 277VAC 127 ~ 392VDC | 90 ~ 277VAC 127 ~ 392VDC | 90 ~ 277VAC 127 ~ 392VDC |
FREQUENCY RANGE | 47 ~ 63Hz | 47 ~ 63Hz | 47 ~ 63Hz | 47 ~ 63Hz | 47 ~ 63Hz | |
POWER FACTOR (Typ.) | PF>0.98/115VAC, PF>0.92/230VAC, PF>0.91/277VAC at full load | PF>0.98/115VAC, PF>0.92/230VAC, PF>0.91/277VAC at full load | PF>0.98/115VAC, PF>0.92/230VAC, PF>0.91/277VAC at full load | PF>0.98/115VAC, PF>0.92/230VAC, PF>0.91/277VAC at full load | PF>0.98/115VAC, PF>0.92/230VAC, PF>0.91/277VAC at full load | |
TOTAL HARMONIC DISTORTION | Total harmonic distortion will be lower than 20% when output loading is 75% or higher | Total harmonic distortion will be lower than 20% when output loading is 75% or higher | Total harmonic distortion will be lower than 20% when output loading is 75% or higher | Total harmonic distortion will be lower than 20% when output loading is 75% or higher | Total harmonic distortion will be lower than 20% when output loading is 75% or higher | |
EFFICIENCY (Typ.) | 89.5% | 89.5% | 88.5% | 87.5% | 86% | |
AC CURRENT | 0.6A/115VAC 0.3A/230VAC 0.2A/277VAC | 0.6A/115VAC 0.3A/230VAC 0.2A/277VAC | 0.6A/115VAC 0.3A/230VAC 0.2A/277VAC | 0.6A/115VAC 0.3A/230VAC 0.2A/277VAC | 0.6A/115VAC 0.3A/230VAC 0.2A/277VAC | |
INRUSH CURRENT(Typ.) | COLD START 17A(t =110 s measured at 50% I ) at 230VAC | COLD START 17A(t =110 s measured at 50% I ) at 230VAC | COLD START 17A(t =110 s measured at 50% I ) at 230VAC | COLD START 17A(t =110 s measured at 50% I ) at 230VAC | COLD START 17A(t =110 s measured at 50% I ) at 230VAC | |
LEAKAGE CURRENT | <0.5mA/ 240VAC | <0.5mA/ 240VAC | <0.5mA/ 240VAC | <0.5mA/ 240VAC | <0.5mA/ 240VAC | |
Specs Sheet |