PLM-40E series

40W Single Output LED Power Supply

 

Application:

Indoor LED lighting
LED Decorative Lighting
LED Office Lighting

Features

 230VAC only or full range(up to 295VAC)
 Built in active PFC function
 Constant current design
 Protections: Short circuit
 Cooling by free air convection
 Fully isolated plastic case
 IP30 design
 Class 2 power unit, no FG
 Class 2 power unit(Blank type only)
 No load power consumption < 0.5W
 High reliability, low cost
 2 year warranty

PLM-40E series

MODELPLM-40E-350PLM-40E-500PLM-40-700
RATED CURRENT350mA500mA700mA
OUTPUTOPERATING VOLTAGE RANGE53 ~ 105V40 ~ 80V 29 ~ 57V
CURRENT ACCURACY±8.0%±8.0%±8.0%
RATED POWER36.75W40W39.9W
RIPPLE & NOISE (max.)10Vp-p8Vp-p6Vp-p
NO LOAD OUTPUT VOLTAGE (max.)115V86V63V
SETUP TIMEBlank Type: 500ms /115VAC, 230VAC at full load; E Type: 500ms / 230VAC at full loadBlank Type: 500ms /115VAC, 230VAC at full load; E Type: 500ms / 230VAC at full loadBlank Type: 500ms /115VAC, 230VAC at full load; E Type: 500ms / 230VAC at full load
INPUTVOLTAGE RANGEBlank Type: E Type: 110 ~ 295VAC 156 ~ 417VDC; 180 ~ 295VAC 254 ~ 417VDCBlank Type: E Type: 110 ~ 295VAC 156 ~ 417VDC; 180 ~ 295VAC 254 ~ 417VDCBlank Type: E Type: 110 ~ 295VAC 156 ~ 417VDC; 180 ~ 295VAC 254 ~ 417VDC
FREQUENCY RANGE47 ~ 63Hz47 ~ 63Hz47 ~ 63Hz
POWER FACTOR (Typ.) - Blank typePF>0.97/115VAC,PF> 0.95/230VAC,PF>0.9/277VAC(at full load)PF>0.97/115VAC,PF> 0.95/230VAC,PF>0.9/277VAC(at full load)PF>0.97/115VAC,PF> 0.95/230VAC,PF>0.9/277VAC(at full load)
POWER FACTOR (Typ.) - E typePF > 0.95/230VAC,PF> 0.9/277VAC PF > 0.95/230VAC,PF> 0.9/277VAC PF > 0.95/230VAC,PF> 0.9/277VAC
TOTALHARMONIC
DISTORTION
THD< 20% when output loading>=60% at 115VAC/230VAC input and output loading>=75% at 277VAC inputTHD< 20% when output loading>=60% at 115VAC/230VAC input and output loading>=75% at 277VAC inputTHD< 20% when output loading>=60% at 115VAC/230VAC input and output loading>=75% at 277VAC input
TOTALHARMONIC
DISTORTION
THD< 20% when output loading>=60% at 230VAC input and output loading>=75% at 277VAC inputTHD< 20% when output loading>=60% at 230VAC input and output loading>=75% at 277VAC inputTHD< 20% when output loading>=60% at 230VAC input and output loading>=75% at 277VAC input
EFFICIENCY
(Typ.)
88%88%87%
AC CURRENTBlank Type: E Type: 0.5A/115VAC 0.3A/230VAC 0.25A/277VAC 0.3A/230VAC 0.25A/277VACBlank Type: E Type: 0.5A/115VAC 0.3A/230VAC 0.25A/277VAC 0.3A/230VAC 0.25A/277VACBlank Type: E Type: 0.5A/115VAC 0.3A/230VAC 0.25A/277VAC 0.3A/230VAC 0.25A/277VAC
INRUSH CURRENT(Typ.) - 60ACOLD START 15A(twidth=75 s measured at 50% Ipeak) at 230VACCOLD START 15A(twidth=75 s measured at 50% Ipeak) at 230VACCOLD START 15A(twidth=75 s measured at 50% Ipeak) at 230VAC
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
47 units (circuit breaker of type B) / 47 units (circuit breaker of type C) at 230VAC47 units (circuit breaker of type B) / 47 units (circuit breaker of type C) at 230VAC47 units (circuit breaker of type B) / 47 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT<0.5mA/ 240VAC<0.5mA/ 240VAC<0.5mA/ 240VAC
Specs Sheet
untitled-3Download PDF
untitled-3Download PDF
untitled-3Download PDF

PLM-40E series

MODELPLM-40-1050 PLM-40-1400 PLM-40-1750
RATED CURRENT1050mA1400mA1750mA
OUTPUTOPERATING VOLTAGE RANGE19 ~ 38V15 ~ 29V 12 ~ 23V
CURRENT ACCURACY±8.0%±8.0%±8.0%
RATED POWER39.9W40.6W 40.25W
RIPPLE & NOISE (max.)4Vp-p3Vp-p2.5Vp-p
NO LOAD OUTPUT VOLTAGE (max.)43V 34V27V
SETUP TIMEBlank Type: 500ms /115VAC, 230VAC at full load; E Type: 500ms / 230VAC at full loadBlank Type: 500ms /115VAC, 230VAC at full load; E Type: 500ms / 230VAC at full loadBlank Type: 500ms /115VAC, 230VAC at full load; E Type: 500ms / 230VAC at full load
INPUTVOLTAGE RANGEBlank Type: E Type: 110 ~ 295VAC 156 ~ 417VDC; 180 ~ 295VAC 254 ~ 417VDCBlank Type: E Type: 110 ~ 295VAC 156 ~ 417VDC; 180 ~ 295VAC 254 ~ 417VDCBlank Type: E Type: 110 ~ 295VAC 156 ~ 417VDC; 180 ~ 295VAC 254 ~ 417VDC
FREQUENCY RANGE47 ~ 63Hz47 ~ 63Hz47 ~ 63Hz
POWER FACTOR (Typ.) - Blank typePF>0.97/115VAC,PF> 0.95/230VAC,PF>0.9/277VAC(at full load)PF>0.97/115VAC,PF> 0.95/230VAC,PF>0.9/277VAC(at full load)PF>0.97/115VAC,PF> 0.95/230VAC,PF>0.9/277VAC(at full load)
POWER FACTOR (Typ.) - E typePF > 0.95/230VAC,PF> 0.9/277VAC PF > 0.95/230VAC,PF> 0.9/277VAC PF > 0.95/230VAC,PF> 0.9/277VAC
TOTALHARMONIC
DISTORTION
THD< 20% when output loading>=60% at 115VAC/230VAC input and output loading>=75% at 277VAC inputTHD< 20% when output loading>=60% at 115VAC/230VAC input and output loading>=75% at 277VAC inputTHD< 20% when output loading>=60% at 115VAC/230VAC input and output loading>=75% at 277VAC input
TOTALHARMONIC
DISTORTION
THD< 20% when output loading>=60% at 230VAC input and output loading>=75% at 277VAC inputTHD< 20% when output loading>=60% at 230VAC input and output loading>=75% at 277VAC inputTHD< 20% when output loading>=60% at 230VAC input and output loading>=75% at 277VAC input
EFFICIENCY
(Typ.)
87%86%86%
AC CURRENTBlank Type: E Type: 0.5A/115VAC 0.3A/230VAC 0.25A/277VAC 0.3A/230VAC 0.25A/277VACBlank Type: E Type: 0.5A/115VAC 0.3A/230VAC 0.25A/277VAC 0.3A/230VAC 0.25A/277VACBlank Type: E Type: 0.5A/115VAC 0.3A/230VAC 0.25A/277VAC 0.3A/230VAC 0.25A/277VAC
INRUSH CURRENT(Typ.) - 60ACOLD START 15A(twidth=75 s measured at 50% Ipeak) at 230VACCOLD START 15A(twidth=75 s measured at 50% Ipeak) at 230VACCOLD START 15A(twidth=75 s measured at 50% Ipeak) at 230VAC
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
47 units (circuit breaker of type B) / 47 units (circuit breaker of type C) at 230VAC47 units (circuit breaker of type B) / 47 units (circuit breaker of type C) at 230VAC47 units (circuit breaker of type B) / 47 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT<0.5mA/ 240VAC<0.5mA/ 240VAC<0.5mA/ 240VAC