LED Power Solutions

powered by Current Automation

HLG-150H series

150W Constant Voltage + Constant Current LED Driver

buy online NOW

NRCS LOA APPROVED

 

 

Application:

LED Lighting
LED Moving Sign

Features

 Constant Voltage + Constant current mode ouput
 Metal housing design with class 1 design
 IP67 / IP65 design for indoor or outdoor installations
 Function options: output adjustable via potentiometer
 3 in 1 dimming (dim-to-off)
 Typical lifetime > 62000 hours
 7 year warranty

HLG-150H series

MODELHLG-150H-12HLG-150H-15HLG-150H-20
OUTPUTDC VOLTAGE12V15V20V
CONSTANT CURRENT REGION6 ~12V 7.5 ~ 15V 10 ~ 20V
RATED CURRENT12.5A 10A7.5A
RATED POWER150W150W150W
RIPPLE & NOISE (max.)150mVp-p150mVp-p150mVp-p
VOLTAGE ADJ. RANGE - Adjustable forA-Type only (via built-in potentiometer)10.8 ~ 13.5V13.5 ~ 17V17 ~ 22V
CURRENT ADJ. RANGE - Adjustable forA-Type only (via built-in potentiometer)7.5 ~ 12.5A6 ~ 10A4.5 ~ 7.5A
VOLTAGE TOLERANCE±2.5%±2.0%±1.0%
LINE REGULATION±0.5%±0.5%±0.5%
LOAD REGULATION±2.0%±1.5%±0.5%
SET UP TIME1000ms,200ms/115VAC 500ms,200ms/230VAC1000ms,200ms/115VAC 500ms,200ms/230VAC1000ms,200ms/115VAC 500ms,200ms/230VAC
HOLD UP TIME (Typ.)16ms/ 115VAC, 230VAC16ms/ 115VAC, 230VAC16ms/ 115VAC, 230VAC
INPUTVOLTAGE RANGE90 ~ 305VAC 127 ~ 431VDC90 ~ 305VAC 127 ~ 431VDC90 ~ 305VAC 127 ~ 431VDC
FREQUENCY RANGE47 ~ 63Hz47 ~ 63Hz47 ~ 63Hz
POWER FACTOR (Typ.)PF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.92/277VAC @ full loadPF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.92/277VAC @ full loadPF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.92/277VAC @ full load
TOTAL HARMONIC DISTORTIONTHD< 20% (@ load>=60% / 115VAC,230VAC; @ load>=75% / 277VAC)THD< 20% (@ load>=60% / 115VAC,230VAC; @ load>=75% / 277VAC)THD< 20% (@ load>=60% / 115VAC,230VAC; @ load>=75% / 277VAC)
EFFICIENCY (Typ.)91.5%92%93%
AC CURRENT (Typ.)1.7A/ 115VAC 0.75A/ 230VAC 0.7A/ 277VAC1.7A/ 115VAC 0.75A/ 230VAC 0.7A/ 277VAC1.7A/ 115VAC 0.75A/ 230VAC 0.7A/ 277VAC
INRUSH CURRENT(Typ.)COLD START 65A(t =425 s measured at 50% I ) at 230VAC; width peak Per NEMA410COLD START 65A(t =425 s measured at 50% I ) at 230VAC; width peak Per NEMA410COLD START 65A(t =425 s measured at 50% I ) at 230VAC; width peak Per NEMA410
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
4 units (circuit breaker of type B) / 7 units (circuit breaker of type C) at 230VAC4 units (circuit breaker of type B) / 7 units (circuit breaker of type C) at 230VAC4 units (circuit breaker of type B) / 7 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT<0.75mA/ 277VAC<0.75mA/ 277VAC<0.75mA/ 277VAC
Specs Sheet
untitled-3Download PDF
untitled-3Download PDF
untitled-3Download PDF

HLG-150H series

MODELHLG-150H-24HLG-150H-30HLG-150H-36
OUTPUTDC VOLTAGE24V30V36V
CONSTANT CURRENT REGION12 ~ 24V 15 ~ 30V18 ~ 36V
RATED CURRENT6.3A5A4.2A
RATED POWER151.2W150W 151.2W
RIPPLE & NOISE (max.)150mVp-p200mVp-p200mVp-p
VOLTAGE ADJ. RANGE - Adjustable forA-Type only (via built-in potentiometer)22 ~ 27V27 ~ 33V33 ~ 40V
CURRENT ADJ. RANGE - Adjustable forA-Type only (via built-in potentiometer)3.8 ~ 6.3A3 ~ 5A2.5 ~ 4.2A
VOLTAGE TOLERANCE±1.0%±1.0%±1.0%
LINE REGULATION±0.5%±0.5%±0.5%
LOAD REGULATION±0.5%±0.5%±0.5%
SET UP TIME1000ms,200ms/115VAC 500ms,200ms/230VAC1000ms,200ms/115VAC 500ms,200ms/230VAC1000ms,200ms/115VAC 500ms,200ms/230VAC
HOLD UP TIME (Typ.)16ms/ 115VAC, 230VAC16ms/ 115VAC, 230VAC16ms/ 115VAC, 230VAC
INPUTVOLTAGE RANGE90 ~ 305VAC 127 ~ 431VDC90 ~ 305VAC 127 ~ 431VDC90 ~ 305VAC 127 ~ 431VDC
FREQUENCY RANGE47 ~ 63Hz47 ~ 63Hz47 ~ 63Hz
POWER FACTOR (Typ.)PF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.92/277VAC @ full loadPF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.92/277VAC @ full loadPF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.93/277VAC @ full load
TOTAL HARMONIC DISTORTIONTHD< 20% (@ load>=60% / 115VAC,230VAC; @ load>=75% / 277VAC)THD< 20% (@ load>=60% / 115VAC,230VAC; @ load>=75% / 277VAC)THD< 20% (@ load>=60% / 115VAC,230VAC; @ load>=75% / 277VAC)
EFFICIENCY (Typ.)93% 93.5% 93.5%
AC CURRENT (Typ.)1.7A/ 115VAC 0.75A/ 230VAC 0.7A/ 277VAC1.7A/ 115VAC 0.75A/ 230VAC 0.7A/ 277VAC1.7A/ 115VAC 0.75A/ 230VAC 0.7A/ 277VAC
INRUSH CURRENT(Typ.)COLD START 65A(t =425 s measured at 50% I ) at 230VAC; width peak Per NEMA410COLD START 65A(t =425 s measured at 50% I ) at 230VAC; width peak Per NEMA410COLD START 65A(t =425 s measured at 50% I ) at 230VAC; width peak Per NEMA410
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
4 units (circuit breaker of type B) / 7 units (circuit breaker of type C) at 230VAC4 units (circuit breaker of type B) / 7 units (circuit breaker of type C) at 230VAC4 units (circuit breaker of type B) / 7 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT<0.75mA/ 277VAC<0.75mA/ 277VAC<0.75mA/ 277VAC
Specs Sheet
untitled-3Download PDF
untitled-3Download PDF
untitled-3Download PDF

HLG-150H series

MODELHLG-150H-42HLG-150H-48HLG-150H-54
OUTPUTDC VOLTAGE42V48V54V
CONSTANT CURRENT REGION21 ~ 42V24 ~ 48V27 ~ 54V
RATED CURRENT3.6A3.2A2.8A
RATED POWER151.2W153.6W151.2W
RIPPLE & NOISE (max.)200mVp-p200mVp-p200mVp-p
VOLTAGE ADJ. RANGE - Adjustable forA-Type only (via built-in potentiometer)40 ~ 46V44 ~ 53V49 ~ 58V
CURRENT ADJ. RANGE - Adjustable forA-Type only (via built-in potentiometer)2.16 ~ 3.6A1.92 ~ 3.2A1.68 ~ 2.8A
VOLTAGE TOLERANCE±1.0%±1.0%±1.0%
LINE REGULATION±0.5%±0.5%±0.5%
LOAD REGULATION±0.5%±0.5%±0.5%
SET UP TIME1000ms,200ms/115VAC 500ms,200ms/230VAC1000ms,200ms/115VAC 500ms,200ms/230VAC1000ms,200ms/115VAC 500ms,200ms/230VAC
HOLD UP TIME (Typ.)16ms/ 115VAC, 230VAC16ms/ 115VAC, 230VAC16ms/ 115VAC, 230VAC
INPUTVOLTAGE RANGE90 ~ 305VAC 127 ~ 431VDC90 ~ 305VAC 127 ~ 431VDC90 ~ 305VAC 127 ~ 431VDC
FREQUENCY RANGE47 ~ 63Hz47 ~ 63Hz47 ~ 63Hz
POWER FACTOR (Typ.)PF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.93/277VAC @ full loadPF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.93/277VAC @ full loadPF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.93/277VAC @ full load
TOTAL HARMONIC DISTORTIONTHD< 20% (@ load>=60% / 115VAC,230VAC; @ load>=75% / 277VAC)THD< 20% (@ load>=60% / 115VAC,230VAC; @ load>=75% / 277VAC)THD< 20% (@ load>=60% / 115VAC,230VAC; @ load>=75% / 277VAC)
EFFICIENCY (Typ.)94%94%94%
AC CURRENT (Typ.)1.7A/ 115VAC 0.75A/ 230VAC 0.7A/ 277VAC1.7A/ 115VAC 0.75A/ 230VAC 0.7A/ 277VAC1.7A/ 115VAC 0.75A/ 230VAC 0.7A/ 277VAC
INRUSH CURRENT(Typ.)COLD START 65A(t =425 s measured at 50% I ) at 230VAC; width peak Per NEMA410COLD START 65A(t =425 s measured at 50% I ) at 230VAC; width peak Per NEMA410COLD START 65A(t =425 s measured at 50% I ) at 230VAC; width peak Per NEMA410
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
4 units (circuit breaker of type B) / 7 units (circuit breaker of type C) at 230VAC4 units (circuit breaker of type B) / 7 units (circuit breaker of type C) at 230VAC4 units (circuit breaker of type B) / 7 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT<0.75mA/ 277VAC<0.75mA/ 277VAC<0.75mA/ 277VAC
Specs Sheet
untitled-3Download PDF
untitled-3Download PDF
untitled-3Download PDF