IDPC-45(A) series

45W Constant Current Mode LED Driver

Application:

LED Lighting
LED Moving Sign

Features

 Constant Current mode output
 Flicker free design
 PCB type design
 Built-in active PFC function
 No load power consumption < 0.5W(Blank-Type)
 Function options: 2 in 1 dimming( dim-to-off) and Auxiliary DC output
  3 year warranty

IDPC-45 series

MODELIDPC-45-350 IDPC-45-500IDPC-45-700
OUTPUTRATED CURRENT350mA500mA700mA
RATED POWER33.25W 45W44.8W
CONSTANT CURRENT REGION57 ~ 95V 54 ~ 90V38 ~ 64V
OPEN CIRCUIT VOLTAGE (118V115V84V
CURRENT RIPPLE5.0% max. @rated current5.0% max. @rated current5.0% max. @rated current
CURRENT TOLERANCE±7.0%±7.0%±7.0%
SETUP TIME500ms / 230VAC 1200ms/115VAC500ms / 230VAC 1200ms/115VAC500ms / 230VAC 1200ms/115VAC
AUXILIARYDC OUTPUTNominal 12V(deviation 11.4~12.6)@50mAforA-Type onlyNominal 12V(deviation 11.4~12.6)@50mAforA-Type onlyNominal 12V(deviation 11.4~12.6)@50mAforA-Type only
INPUTVOLTAGE RANGE90 ~ 295VAC 127 ~ 417VDC90 ~ 295VAC 127 ~ 417VDC90 ~ 295VAC 127 ~ 417VDC
FREQUENCY RANGE47 ~ 63Hz47 ~ 63Hz47 ~ 63Hz
POWER FACTORPF>=0.95/115VAC, PF>=0.92/230VAC, PF>=0.9/277VAC@full loadPF>=0.95/115VAC, PF>=0.92/230VAC, PF>=0.9/277VAC@full loadPF>=0.95/115VAC, PF>=0.92/230VAC, PF>=0.9/277VAC@full load
TOTAL HARMONIC DISTORTIONTHD< 20%(@load>=60%/115VAC,230VAC; @load>=75%/277VAC)THD< 20%(@load>=60%/115VAC,230VAC; @load>=75%/277VAC)THD< 20%(@load>=60%/115VAC,230VAC; @load>=75%/277VAC)
EFFICIENCY (Typ.)86%85%85%
AC CURRENT (Typ.)0.6A/115VAC 0.4A/230VAC 0.3A/277VAC0.6A/115VAC 0.4A/230VAC 0.3A/277VAC0.6A/115VAC 0.4A/230VAC 0.3A/277VAC
INRUSH CURRENT (Typ.)COLD START 30A(twidth= s measured at 50% Ipeak) at 230VAC 100μ ; Per NEMA410COLD START 30A(twidth= s measured at 50% Ipeak) at 230VAC 100μ ; Per NEMA410COLD START 30A(twidth= s measured at 50% Ipeak) at 230VAC 100μ ; Per NEMA410
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
32 units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 230VAC32 units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 230VAC32 units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT<0.75mA/ 277VAC<0.75mA/ 277VAC<0.75mA/ 277VAC
NO LOAD POWER CONSUMPTION<0.5W for Blank-Type, <1.2W forA-Type <0.5W for Blank-Type, <1.2W forA-Type <0.5W for Blank-Type, <1.2W forA-Type
Specs Sheet
untitled-3Download PDF
untitled-3Download PDF
untitled-3Download PDF

IDPC-45 series

MODELIDPC-45-1050IDPC-45-1400
OUTPUTRATED CURRENT1050mA1400mA
RATED POWER45.15W44.8W
CONSTANT CURRENT REGION26 ~ 43V19 ~ 32V
OPEN CIRCUIT VOLTAGE (63V50V
CURRENT RIPPLE5.0% max. @rated current5.0% max. @rated current
CURRENT TOLERANCE±7.0%±7.0%
SETUP TIME500ms / 230VAC 1200ms/115VAC500ms / 230VAC 1200ms/115VAC
AUXILIARYDC OUTPUTNominal 12V(deviation 11.4~12.6)@50mAforA-Type onlyNominal 12V(deviation 11.4~12.6)@50mAforA-Type only
INPUTVOLTAGE RANGE90 ~ 295VAC 127 ~ 417VDC90 ~ 295VAC 127 ~ 417VDC
FREQUENCY RANGE47 ~ 63Hz47 ~ 63Hz
POWER FACTORPF>=0.95/115VAC, PF>=0.92/230VAC, PF>=0.9/277VAC@full loadPF>0.95/115VAC, PF>0.92/230VAC, PF>0.9/277VAC@full load
TOTAL HARMONIC DISTORTIONTHD< 20%(@load>=60%/115VAC,230VAC; @load>=75%/277VAC)THD< 20%(@load>=60%/115VAC,230VAC; @load>=75%/277VAC)
EFFICIENCY (Typ.)84%83%
AC CURRENT (Typ.)0.6A/115VAC 0.4A/230VAC 0.3A/277VAC0.6A/115VAC 0.4A/230VAC 0.3A/277VAC
INRUSH CURRENT (Typ.)COLD START 30A(twidth= s measured at 50% Ipeak) at 230VAC 100μ ; Per NEMA410COLD START 30A(twidth= s measured at 50% Ipeak) at 230VAC 100μ ; Per NEMA410
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
32 units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 230VAC32 units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT<0.75mA/ 277VAC<0.75mA/ 277VAC
NO LOAD POWER CONSUMPTION<0.5W for Blank-Type, <1.2W forA-Type <0.5W for Blank-Type, <1.2W forA-Type