60W Constant Voltage + Constant Current LED Driver

NRCS LOA APPROVED

 

 

buy online NOW

Application:

LED decorative lighting
LED office lighting
Indoor LED lighting

Features

 Constant Voltage + Constant Current mode output
 Plastic housing with class 2 design
 Built-in active PFC function
 Class 2 power unit
 Fully encapsulated with IP67 level
 Typical lifetime > 50000 hours
 5 years warranty

LPF-60 series

MODELLPF-60-12LPF-60-15LPF-60-20
OUTPUTDC VOLTAGE12V15V20V
CONSTANT CURRENT REGION7.2 ~12V9 ~ 15V12 ~ 20V
RATED CURRENT5A4A3A
RATED POWER60W60W60W
RIPPLE & NOISE150mVp-p 150mVp-p 150mVp-p
VOLTAGE TOLERANCE±4.0% ±4.0% ±4.0%
LINE REGULATION±0.5%±0.5%±0.5%
LOAD REGULATION±2.0%±1.5%±1.0%
SETUP TIME1000ms, 80ms / 115VAC 500ms, 80ms / 230VAC1000ms, 80ms / 115VAC 500ms, 80ms / 230VAC1000ms, 80ms / 115VAC 500ms, 80ms / 230VAC
HOLD UP TIME (Typ.)6ms/230VAC 16ms/115VAC6ms/230VAC 16ms/115VAC6ms/230VAC 16ms/115VAC
INPUTVOLTAGE RANGE90 ~ 305VAC 127 ~ 431VDC90 ~ 305VAC 127 ~ 431VDC90 ~ 305VAC 127 ~ 431VDC
FREQUENCY RANGE47 ~ 63Hz47 ~ 63Hz47 ~ 63Hz
POWER FACTOR (Typ.)PF 0.97/115VAC, PF 0.95/230VAC, PF 0.92/277VAC@full loadPF 0.97/115VAC, PF 0.95/230VAC, PF 0.92/277VAC@full loadPF 0.97/115VAC, PF 0.95/230VAC, PF 0.92/277VAC@full load
TOTAL HARMONIC DISTORTIONTHD< 20%(@load 60%/115VC,230VAC; @load 75%/277VAC)THD< 20%(@load 60%/115VC,230VAC; @load 75%/277VAC)THD< 20%(@load 60%/115VC,230VAC; @load 75%/277VAC)
EFFICIENCY (Typ.)86%87%88%
AC CURRENT0.8A/ 115VAC 0.4A/ 230VAC 0.32A/277VAC0.8A/ 115VAC 0.4A/ 230VAC 0.32A/277VAC0.8A/ 115VAC 0.4A/ 230VAC 0.32A/277VAC
INRUSH CURRENT(Typ.)COLD START 55A(twidth=270 s measured at 50% Ipeak) at 230VAC μ ; Per NEMA410COLD START 55A(twidth=270 s measured at 50% Ipeak) at 230VAC μ ; Per NEMA410COLD START 55A(twidth=270 s measured at 50% Ipeak) at 230VAC μ ; Per NEMA410
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
8 units (circuit breaker of type B) / 14 units (circuit breaker of type C) at 230VAC8 units (circuit breaker of type B) / 14 units (circuit breaker of type C) at 230VAC8 units (circuit breaker of type B) / 14 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT<0.75mA/ 240VAC<0.75mA/ 240VAC<0.75mA/ 240VAC
Specs Sheet
untitled-3Download PDF
untitled-3Download PDF
untitled-3Download PDF

LPF-60 series

MODELLPF-60-24LPF-60-30LPF-60-36
OUTPUTDC VOLTAGE24V30V36V
CONSTANT CURRENT REGION14.4 ~ 24V18 ~ 30V21.6 ~ 36V
RATED CURRENT2.5A2A1.67A
RATED POWER60W60W60.12W
RIPPLE & NOISE150mVp-p 200mVp-p250mVp-p
VOLTAGE TOLERANCE±4.0% ±4.0% ±4.0%
LINE REGULATION±0.5%±0.5%±0.5%
LOAD REGULATION±0.5%±0.5%±0.5%
SETUP TIME1000ms, 80ms / 115VAC 500ms, 80ms / 230VAC1000ms, 80ms / 115VAC 500ms, 80ms / 230VAC1000ms, 80ms / 115VAC 500ms, 80ms / 230VAC
HOLD UP TIME (Typ.)6ms/230VAC 16ms/115VAC6ms/230VAC 16ms/115VAC6ms/230VAC 16ms/115VAC
INPUTVOLTAGE RANGE90 ~ 305VAC 127 ~ 431VDC90 ~ 305VAC 127 ~ 431VDC90 ~ 305VAC 127 ~ 431VDC
FREQUENCY RANGE47 ~ 63Hz47 ~ 63Hz47 ~ 63Hz
POWER FACTOR (Typ.)PF 0.97/115VAC, PF 0.95/230VAC, PF 0.92/277VAC@full loadPF 0.97/115VAC, PF 0.95/230VAC, PF 0.92/277VAC@full loadPF 0.97/115VAC, PF 0.95/230VAC, PF 0.92/277VAC@full load
TOTAL HARMONIC DISTORTIONTHD< 20%(@load 60%/115VC,230VAC; @load 75%/277VAC)THD< 20%(@load 60%/115VC,230VAC; @load 75%/277VAC)THD< 20%(@load 60%/115VC,230VAC; @load 75%/277VAC)
EFFICIENCY (Typ.)89%90%90%
AC CURRENT0.8A/ 115VAC 0.4A/ 230VAC 0.32A/277VAC0.8A/ 115VAC 0.4A/ 230VAC 0.32A/277VAC0.8A/ 115VAC 0.4A/ 230VAC 0.32A/277VAC
INRUSH CURRENT(Typ.)COLD START 55A(twidth=270 s measured at 50% Ipeak) at 230VAC μ ; Per NEMA410COLD START 55A(twidth=270 s measured at 50% Ipeak) at 230VAC μ ; Per NEMA410COLD START 55A(twidth=270 s measured at 50% Ipeak) at 230VAC μ ; Per NEMA410
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
8 units (circuit breaker of type B) / 14 units (circuit breaker of type C) at 230VAC8 units (circuit breaker of type B) / 14 units (circuit breaker of type C) at 230VAC8 units (circuit breaker of type B) / 14 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT<0.75mA/ 240VAC<0.75mA/ 240VAC<0.75mA/ 240VAC
Specs Sheet
untitled-3Download PDF
untitled-3Download PDF
untitled-3Download PDF

LPF-60 series

MODELLPF-60-42LPF-60-48LPF-60-54
OUTPUTDC VOLTAGE42V48V54V
CONSTANT CURRENT REGION25.2 ~ 42V28.8 ~ 48V32.4 ~ 54V
RATED CURRENT1.43A1.25A1.12A
RATED POWER60.06W60W60.48W
RIPPLE & NOISE250mVp-p 250mVp-p 350mVp-p
VOLTAGE TOLERANCE±4.0% ±4.0% ±4.0%
LINE REGULATION±0.5%±0.5%±0.5%
LOAD REGULATION±0.5%±0.5%±0.5%
SETUP TIME1000ms, 80ms / 115VAC 500ms, 80ms / 230VAC1000ms, 80ms / 115VAC 500ms, 80ms / 230VAC1000ms, 80ms / 115VAC 500ms, 80ms / 230VAC
HOLD UP TIME (Typ.)6ms/230VAC 16ms/115VAC6ms/230VAC 16ms/115VAC6ms/230VAC 16ms/115VAC
INPUTVOLTAGE RANGE90 ~ 305VAC 127 ~ 431VDC90 ~ 305VAC 127 ~ 431VDC90 ~ 305VAC 127 ~ 431VDC
FREQUENCY RANGE47 ~ 63Hz47 ~ 63Hz47 ~ 63Hz
POWER FACTOR (Typ.)PF 0.97/115VAC, PF 0.95/230VAC, PF 0.92/277VAC@full loadPF 0.97/115VAC, PF 0.95/230VAC, PF 0.92/277VAC@full loadPF 0.97/115VAC, PF 0.95/230VAC, PF 0.92/277VAC@full load
TOTAL HARMONIC DISTORTIONTHD< 20%(@load 60%/115VC,230VAC; @load 75%/277VAC)THD< 20%(@load 60%/115VC,230VAC; @load 75%/277VAC)THD< 20%(@load 60%/115VC,230VAC; @load 75%/277VAC)
EFFICIENCY (Typ.)90%90%90%
AC CURRENT0.8A/ 115VAC 0.4A/ 230VAC 0.32A/277VAC0.8A/ 115VAC 0.4A/ 230VAC 0.32A/277VAC0.8A/ 115VAC 0.4A/ 230VAC 0.32A/277VAC
INRUSH CURRENT(Typ.)COLD START 55A(twidth=270 s measured at 50% Ipeak) at 230VAC μ ; Per NEMA410COLD START 55A(twidth=270 s measured at 50% Ipeak) at 230VAC μ ; Per NEMA410COLD START 55A(twidth=270 s measured at 50% Ipeak) at 230VAC μ ; Per NEMA410
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
8 units (circuit breaker of type B) / 14 units (circuit breaker of type C) at 230VAC8 units (circuit breaker of type B) / 14 units (circuit breaker of type C) at 230VAC8 units (circuit breaker of type B) / 14 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT<0.75mA/ 240VAC<0.75mA/ 240VAC<0.75mA/ 240VAC