HLG-100H series
100W Constant Voltage + Constant Current LED Driver
NRCS LOA APPROVED
|
Application:
Features
Constant Voltage + Constant current mode ouput
Metal housing design with class 1 design
Built-in active PFC function
Class 2 power unit
IP67 / IP65 design for indoor or outdoor installations
Function options: output adjustable via potentiometer
3 in 1 dimming (dim-to-off)
Timer Dimming
Typical lifetime > 62000 hours
7 year warranty
HLG-100H series
MODEL | HLG-100H-20 | HLG-100H-24 | HLG-100H-30 | HLG-100H-36 | |
---|---|---|---|---|---|
OUTPUT | DC VOLTAGE | 20V | 24V | 30V | 36V |
CONSTANT CURRENT REGION | 10 ~ 20V | 12 ~ 24V | 15 ~ 30V | 18 ~ 36V | |
RATED CURRENT | 4.8A | 4A | 3.2A | 2.65A | |
RATED POWER | 96W | 96W | 96W | 95.4W | |
RIPPLE & NOISE (max.) | 150mVp-p | 150mVp-p | 200mVp-p | 200mVp-p | |
VOLTAGE ADJ. RANGE - Adjustable forA-Type only (via built-in potentiometer) | 17 ~ 22V | 22 ~ 27V | 27 ~ 33V | 33 ~ 40V | |
CURRENT ADJ. RANGE - Adjustable forA-Type only (via built-in potentiometer) | 3 ~ 4.8A | 2.5 ~ 4A | 2 ~ 3.2A | 1.65 ~ 2.65A | |
VOLTAGE TOLERANCE | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
SET UP TIME | 1200ms,50ms/115VAC 500ms,50ms/230VAC | 1200ms,50ms/115VAC 500ms,50ms/230VAC | 1200ms,50ms/115VAC 500ms,50ms/230VAC | 1200ms,50ms/115VAC 500ms,50ms/230VAC | |
HOLD UP TIME (Typ.) | 16ms / 115VAC, 230VAC | 16ms / 115VAC, 230VAC | 16ms / 115VAC, 230VAC | 16ms / 115VAC, 230VAC | |
INPUT | VOLTAGE RANGE | 90 ~ 305VAC 127 ~ 431VDC | 90 ~ 305VAC 127 ~ 431VDC | 90 ~ 305VAC 127 ~ 431VDC | 90 ~ 305VAC 127 ~ 431VDC |
FREQUENCY RANGE | 47 ~ 63Hz | 47 ~ 63Hz | 47 ~ 63Hz | 47 ~ 63Hz | |
POWER FACTOR (Typ.) | PF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.93/277VAC @ full load | PF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.93/277VAC @ full load | PF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.93/277VAC @ full load | PF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.93/277VAC @ full load | |
TOTAL HARMONIC DISTORTION | THD< 20% (@>=load 60% / 115VAC,230VAC; @ load>=75% / 277VAC) | THD< 20% (@>=load 60% / 115VAC,230VAC; @ load>=75% / 277VAC) | THD< 20% (@>=load 60% / 115VAC,230VAC; @ load>=75% / 277VAC) | THD< 20% (@>=load 60% / 115VAC,230VAC; @ load>=75% / 277VAC) | |
EFFICIENCY (Typ.) | 93% | 93% | 93% | 93% | |
AC CURRENT (Typ.) | 1.2A/ 115VAC 0.55A/ 230VAC 0.5A/ 277VAC | 1.2A/ 115VAC 0.55A/ 230VAC 0.5A/ 277VAC | 1.2A/ 115VAC 0.55A/ 230VAC 0.5A/ 277VAC | 1.2A/ 115VAC 0.55A/ 230VAC 0.5A/ 277VAC | |
INRUSH CURRENT(Typ.) | COLD START 70A(t =485 s measured at 50% I ) at 230VAC width peak ; Per NEMA410 | COLD START 60A(t =415 s measured at 50% I ) at 230VAC width peak ; Per NEMA410 | COLD START 60A(t =415 s measured at 50% I ) at 230VAC width peak ; Per NEMA410 | COLD START 60A(t =415 s measured at 50% I ) at 230VAC width peak ; Per NEMA410 | |
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 4 units (circuit breaker of type B) / 8 units (circuit breaker of type C) at 230VAC | 4 units (circuit breaker of type B) / 8 units (circuit breaker of type C) at 230VAC | 4 units (circuit breaker of type B) / 8 units (circuit breaker of type C) at 230VAC | 4 units (circuit breaker of type B) / 8 units (circuit breaker of type C) at 230VAC | |
LEAKAGE CURRENT | <0.75mA/ 277VAC | <0.75mA/ 277VAC | <0.75mA/ 277VAC | <0.75mA/ 277VAC | |
Specs Sheet |
HLG-100H series
MODEL | HLG-100H-42 | HLG-100H-48 | HLG-100H-54 | |
---|---|---|---|---|
OUTPUT | DC VOLTAGE | 42V | 48V | 54V |
CONSTANT CURRENT REGION | 21 ~ 42V | 24 ~ 48V | 27 ~ 54V | |
RATED CURRENT | 2.28A | 2A | 1.77A | |
RATED POWER | 95.76W | 96W | 95.58W | |
RIPPLE & NOISE (max.) | 200mVp-p | 200mVp-p | 200mVp-p | |
VOLTAGE ADJ. RANGE - Adjustable forA-Type only (via built-in potentiometer) | 40 ~ 46V | 44 ~ 53V | 49 ~ 58V | |
CURRENT ADJ. RANGE - Adjustable forA-Type only (via built-in potentiometer) | 1.4 ~ 2.28A | 1.25 ~ 2A | 1.1 ~ 1.77A | |
VOLTAGE TOLERANCE | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±0.5% | ±0.5% | ±0.5% | |
SET UP TIME | 1200ms,50ms/115VAC 500ms,50ms/230VAC | 1200ms,50ms/115VAC 500ms,50ms/230VAC | 1200ms,50ms/115VAC 500ms,50ms/230VAC | |
HOLD UP TIME (Typ.) | 16ms / 115VAC, 230VAC | 16ms / 115VAC, 230VAC | 16ms / 115VAC, 230VAC | |
INPUT | VOLTAGE RANGE | 90 ~ 305VAC 127 ~ 431VDC | 90 ~ 305VAC 127 ~ 431VDC | 90 ~ 305VAC 127 ~ 431VDC |
FREQUENCY RANGE | 47 ~ 63Hz | 47 ~ 63Hz | 47 ~ 63Hz | |
POWER FACTOR (Typ.) | PF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.93/277VAC @ full load | PF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.93/277VAC @ full load | PF>=0.98/115VAC, PF>=0.95/230VAC, PF>=0.93/277VAC @ full load | |
TOTAL HARMONIC DISTORTION | THD< 20% (@>=load 60% / 115VAC,230VAC; @ load>=75% / 277VAC) | THD< 20% (@>=load 60% / 115VAC,230VAC; @ load>=75% / 277VAC) | THD< 20% (@>=load 60% / 115VAC,230VAC; @ load>=75% / 277VAC) | |
EFFICIENCY (Typ.) | 93% | 93% | 93% | |
AC CURRENT (Typ.) | 1.2A/ 115VAC 0.55A/ 230VAC 0.5A/ 277VAC | 1.2A/ 115VAC 0.55A/ 230VAC 0.5A/ 277VAC | 1.2A/ 115VAC 0.55A/ 230VAC 0.5A/ 277VAC | |
INRUSH CURRENT(Typ.) | COLD START 60A(t =415 s measured at 50% I ) at 230VAC width peak ; Per NEMA410 | COLD START 60A(t =415 s measured at 50% I ) at 230VAC width peak ; Per NEMA410 | COLD START 60A(t =415 s measured at 50% I ) at 230VAC width peak ; Per NEMA410 | |
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 4 units (circuit breaker of type B) / 8 units (circuit breaker of type C) at 230VAC | 4 units (circuit breaker of type B) / 8 units (circuit breaker of type C) at 230VAC | 4 units (circuit breaker of type B) / 8 units (circuit breaker of type C) at 230VAC | |
LEAKAGE CURRENT | <0.75mA/ 277VAC | <0.75mA/ 277VAC | <0.75mA/ 277VAC | |
Specs Sheet |