PLC-60 series
60W Single Output LED Power Supply
Application:
Features
Universal AC input / Full range
High efficiency up to 89%
Adjustable output voltage and current level
Protections: Short circuit / Over temperature / Over voltage / Over temperature
Cooling by free air convection
Built in constant current limiting circuit
Fully isolated plastic case with terminal block style of I/O
Built-in active PFC function, comply with EN61000-3-2 class C (≧75% load)
Class 2 power unit
Pass LPS
100% full load burn-in test
High reliability
Suitable for LED lighting and moving sign applications
Compliance to worldwide safety regulations for lighting
3 years warranty
PLC-60 series
MODEL | PLC-60-12 | PLC-60-15 | PLC-60-15 | PLC-60-20 | |
---|---|---|---|---|---|
OUTPUT | DC VOLTAGE | 12V | 15V | 15V | 20V |
CONSTANT CURRENT REGION | 8.4 ~ 12V | 10.5 ~15V | 10.5 ~15V | 14 ~ 20V | |
RATED CURRENT | 5A | 4A | 4A | 3A | |
CURRENT RANGE | 0 ~ 5A | 0 ~ 4A | 0 ~ 4A | 0 ~ 3A | |
RATED POWER | 60W | 60W | 60W | 60W | |
RIPPLE & NOISE (max.) | 2Vp-p | 2.4Vp-p | 2.4Vp-p | 1.8Vp-p | |
VOLTAGEADJ. RANGE | 11.5 ~ 13V | 14.5 ~ 16.2V | 14.5 ~ 16.2V | 19.5 ~ 22V | |
CURRENTADJ. RANGE | 3.75 ~ 5.15A | 3 ~ 4.12A | 3 ~ 4.12A | 2.25 ~ 3.09A | |
VOLTAGE TOLERANCE | ±10% | ±10% | ±10% | ±10% | |
LINE REGULATION | ±3.0% | ±3.0% | ±3.0% | ±3.0% | |
LOAD REGULATION | ±5.0% | ±5.0% | ±5.0% | ±5.0% | |
SETUP TIME | 500ms / 230VAC 3000ms / 115VAC at full load | 500ms / 230VAC 3000ms / 115VAC at full load | 500ms / 230VAC 3000ms / 115VAC at full load | 500ms / 230VAC 3000ms / 115VAC at full load | |
INPUT | VOLTAGE RANGE | 90 ~ 264VAC 127 ~ 370VDC | 90 ~ 264VAC 127 ~ 370VDC | 90 ~ 264VAC 127 ~ 370VDC | 90 ~ 264VAC 127 ~ 370VDC |
FREQUENCY RANGE | 47 ~ 63Hz | 47 ~ 63Hz | 47 ~ 63Hz | 47 ~ 63Hz | |
POWER FACTOR (Typ.) | PF>0.92/115VAC, PF>0.9/230VAC at full load | PF>0.92/115VAC, PF>0.9/230VAC at full load | PF>0.92/115VAC, PF>0.9/230VAC at full load | PF>0.92/115VAC, PF>0.9/230VAC at full load | |
TOTAL HARMONIC DISTORTION | THD< 20% when output loading 75% at 115VAC/230VAC input | THD< 20% when output loading 75% at 115VAC/230VAC input | THD< 20% when output loading 75% at 115VAC/230VAC input | THD< 20% when output loading 75% at 115VAC/230VAC input | |
EFFICIENCY (Typ.) | 85% | 86% | 86% | 87.5% | |
AC CURRENT | 0.8A/115VAC 0.4A/230VAC | 0.8A/115VAC 0.4A/230VAC | 0.8A/115VAC 0.4A/230VAC | 0.8A/115VAC 0.4A/230VAC | |
INRUSH CURRENT(Typ.) | COLD START 35A(twidth=35 s measured at 50% Ipeak) at 230VAC | COLD START 35A(twidth=35 s measured at 50% Ipeak) at 230VAC | COLD START 35A(twidth=35 s measured at 50% Ipeak) at 230VAC | COLD START 35A(twidth=35 s measured at 50% Ipeak) at 230VAC | |
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 32 units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 230VAC | 32 units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 230VAC | 32 units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 230VAC | 32 units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 230VAC | |
LEAKAGE CURRENT | <0.75mA/ 240VAC | <0.75mA/ 240VAC | <0.75mA/ 240VAC | <0.75mA/ 240VAC | |
Specs Sheet |
PLC-60 series
MODEL | PLC-60-27 | PLC-60-36 | PLC-60-48 | |
---|---|---|---|---|
OUTPUT | DC VOLTAGE | 27V | 36V | 48V |
CONSTANT CURRENT REGION | 18.9 ~27V | 25.2 ~ 36V | 33.6 ~ 48V | |
RATED CURRENT | 2.3A | 1.7A | 1.3A | |
CURRENT RANGE | 0 ~ 2.3A | 0 ~ 1.7A | 0 ~ 1.3A | |
RATED POWER | 62.1W | 61.2W | 62.4W | |
RIPPLE & NOISE (max.) | 2.7Vp-p | 3.6Vp-p | 4.6Vp-p | |
VOLTAGEADJ. RANGE | 25 ~ 30V | 32.5 ~ 39V | 43.6 ~ 51.8V | |
CURRENTADJ. RANGE | 1.725 ~ 2.369A | 1.275 ~ 1.751A | 0.975 ~ 1.339A | |
VOLTAGE TOLERANCE | ±10% | ±10% | ±10% | |
LINE REGULATION | ±3.0% | ±3.0% | ±3.0% | |
LOAD REGULATION | ±5.0% | ±5.0% | ±5.0% | |
SETUP TIME | 500ms / 230VAC 3000ms / 115VAC at full load | 500ms / 230VAC 3000ms / 115VAC at full load | 500ms / 230VAC 3000ms / 115VAC at full load | |
INPUT | VOLTAGE RANGE | 90 ~ 264VAC 127 ~ 370VDC | 90 ~ 264VAC 127 ~ 370VDC | 90 ~ 264VAC 127 ~ 370VDC |
FREQUENCY RANGE | 47 ~ 63Hz | 47 ~ 63Hz | 47 ~ 63Hz | |
POWER FACTOR (Typ.) | PF>0.92/115VAC, PF>0.9/230VAC at full load | PF>0.92/115VAC, PF>0.9/230VAC at full load | PF>0.92/115VAC, PF>0.9/230VAC at full load | |
TOTAL HARMONIC DISTORTION | THD< 20% when output loading 75% at 115VAC/230VAC input | THD< 20% when output loading 75% at 115VAC/230VAC input | THD< 20% when output loading 75% at 115VAC/230VAC input | |
EFFICIENCY (Typ.) | 88% | 89% | 89% | |
AC CURRENT | 0.8A/115VAC 0.4A/230VAC | 0.8A/115VAC 0.4A/230VAC | 0.8A/115VAC 0.4A/230VAC | |
INRUSH CURRENT(Typ.) | COLD START 35A(twidth=35 s measured at 50% Ipeak) at 230VAC | COLD START 35A(twidth=35 s measured at 50% Ipeak) at 230VAC | COLD START 35A(twidth=35 s measured at 50% Ipeak) at 230VAC | |
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 32 units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 230VAC | 32 units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 230VAC | 32 units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 230VAC | |
LEAKAGE CURRENT | <0.75mA/ 240VAC | <0.75mA/ 240VAC | <0.75mA/ 240VAC | |
Specs Sheet |