NPF-120 series

120W Constant Voltage + Constant Current LED Driver

Application:

LED decorative lighting
LED office lighting
Indoor LED lighting

Features

 Constant Voltage + Constant Current mode output
 Plastic housing with class 2 design
 Built-in active PFC function
 Class 2 power unit(except NPF-90-12/15)
 No load power consumption <0.15W
 P67 rating for indoor or outdoor installations
 Typical lifetime > 50000 hours
 5 years warranty

NPF-120 series

MODELNPF-120-12NPF-120-15NPF-120-20
OUTPUTDC VOLTAGE12V15V20V
CONSTANT CURRENT REGION7.2 ~ 12V9 ~ 15V 12 ~ 20V
RATED CURRENT10A8A6A
RATED POWER120W120W120W
RIPPLE & NOISE150mVp-p150mVp-p150mVp-p
VOLTAGE TOLERANCE±4.0%±4.0%±4.0%
LINE REGULATION±0.5%±0.5%±0.5%
LOAD REGULATION±2.0%±1.5%±1.0%
SETUP TIME500ms, 80ms 115VAC / 230VAC500ms, 80ms 115VAC / 230VAC500ms, 80ms 115VAC / 230VAC
HOLD UP TIME (Typ.)16ms/230VAC 16ms/115VAC16ms/230VAC 16ms/115VAC16ms/230VAC 16ms/115VAC
INPUTVOLTAGE RANGE90 ~ 305VAC 127 ~ 431VDC90 ~ 305VAC 127 ~ 431VDC90 ~ 305VAC 127 ~ 431VDC
FREQUENCY RANGE47 ~ 63Hz47 ~ 63Hz47 ~ 63Hz
POWER FACTOR (Typ.)PF 0.97/115VAC, PF 0.96/230VAC, PF 0.94/277VAC@full loadPF 0.97/115VAC, PF 0.96/230VAC, PF 0.94/277VAC@full loadPF 0.97/115VAC, PF 0.96/230VAC, PF 0.94/277VAC@full load
TOTAL HARMONIC DISTORTIONTHD< 20%(@load 60%/115VC,230VAC; @load 75%/277VAC)THD< 20%(@load 60%/115VC,230VAC; @load 75%/277VAC)THD< 20%(@load 60%/115VC,230VAC; @load 75%/277VAC)
EFFICIENCY (Typ.)89%89% 90%
AC CURRENT1.3A/ 115VAC 0.65A/ 230VAC 0.55A/ 277VAC1.3A/ 115VAC 0.65A/ 230VAC 0.55A/ 277VAC1.3A/ 115VAC 0.65A/ 230VAC 0.55A/ 277VAC
INRUSH CURRENT(Typ.)COLD START 60A(twidth=520 s measured at 50% Ipeak) at 230VAC μ ; Per NEMA410COLD START 60A(twidth=520 s measured at 50% Ipeak) at 230VAC μ ; Per NEMA410COLD START 60A(twidth=520 s measured at 50% Ipeak) at 230VAC μ ; Per NEMA410
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
4 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC4 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC4 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT<0.25mA/ 277VAC<0.25mA/ 277VAC<0.25mA/ 277VAC
NO LOAD POWER CONSUMPTION<0.15W <0.15W <0.15W
Specs Sheet
untitled-3Download PDF
untitled-3Download PDF
untitled-3Download PDF

NPF-120 series

MODELNPF-120-24NPF-120-30 NPF-120-36
OUTPUTDC VOLTAGE24V30V36V
CONSTANT CURRENT REGION14.4 ~ 24V18 ~ 30V21.6 ~ 36V
RATED CURRENT5A4A3.4A
RATED POWER120W120W122.4W
RIPPLE & NOISE150mVp-p200mVp-p200mVp-p
VOLTAGE TOLERANCE±3.0% ±4.0%±2.0%
LINE REGULATION±0.5%±0.5%±0.5%
LOAD REGULATION±0.5%±0.5%±0.5%
SETUP TIME500ms, 80ms 115VAC / 230VAC500ms, 80ms 115VAC / 230VAC500ms, 80ms 115VAC / 230VAC
HOLD UP TIME (Typ.)16ms/230VAC 16ms/115VAC16ms/230VAC 16ms/115VAC16ms/230VAC 16ms/115VAC
INPUTVOLTAGE RANGE90 ~ 305VAC 127 ~ 431VDC90 ~ 305VAC 127 ~ 431VDC90 ~ 305VAC 127 ~ 431VDC
FREQUENCY RANGE47 ~ 63Hz47 ~ 63Hz47 ~ 63Hz
POWER FACTOR (Typ.)PF 0.97/115VAC, PF 0.96/230VAC, PF 0.94/277VAC@full loadPF 0.97/115VAC, PF 0.96/230VAC, PF 0.94/277VAC@full loadPF 0.97/115VAC, PF 0.96/230VAC, PF 0.94/277VAC@full load
TOTAL HARMONIC DISTORTIONTHD< 20%(@load 60%/115VC,230VAC; @load 75%/277VAC)THD< 20%(@load 60%/115VC,230VAC; @load 75%/277VAC)THD< 20%(@load 60%/115VC,230VAC; @load 75%/277VAC)
EFFICIENCY (Typ.)90.5%89.5%90%
AC CURRENT1.3A/ 115VAC 0.65A/ 230VAC 0.55A/ 277VAC1.3A/ 115VAC 0.65A/ 230VAC 0.55A/ 277VAC1.3A/ 115VAC 0.65A/ 230VAC 0.55A/ 277VAC
INRUSH CURRENT(Typ.)COLD START 60A(twidth=520 s measured at 50% Ipeak) at 230VAC μ ; Per NEMA410COLD START 60A(twidth=520 s measured at 50% Ipeak) at 230VAC μ ; Per NEMA410COLD START 60A(twidth=520 s measured at 50% Ipeak) at 230VAC μ ; Per NEMA410
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
4 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC4 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC4 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT<0.25mA/ 277VAC<0.25mA/ 277VAC<0.25mA/ 277VAC
NO LOAD POWER CONSUMPTION<0.15W <0.15W <0.15W
Specs Sheet
untitled-3Download PDF
untitled-3Download PDF
untitled-3Download PDF

NPF-120 series

MODELNPF-120-42 NPF-120-48NPF-120-54
OUTPUTDC VOLTAGE42V48V54V
CONSTANT CURRENT REGION25.2 ~ 42V28.8 ~ 48V32.4 ~ 54V
RATED CURRENT2.9A2.5A2.3A
RATED POWER121.8W120W124.2W
RIPPLE & NOISE250mVp-p250mVp-p350mVp-p
VOLTAGE TOLERANCE±1.0% ±1.0%±1.0%
LINE REGULATION±0.5%±0.5%±0.5%
LOAD REGULATION±0.5%±0.5%±0.5%
SETUP TIME500ms, 80ms 115VAC / 230VAC500ms, 80ms 115VAC / 230VAC500ms, 80ms 115VAC / 230VAC
HOLD UP TIME (Typ.)16ms/230VAC 16ms/115VAC16ms/230VAC 16ms/115VAC16ms/230VAC 16ms/115VAC
INPUTVOLTAGE RANGE90 ~ 305VAC 127 ~ 431VDC90 ~ 305VAC 127 ~ 431VDC90 ~ 305VAC 127 ~ 431VDC
FREQUENCY RANGE47 ~ 63Hz47 ~ 63Hz47 ~ 63Hz
POWER FACTOR (Typ.)PF 0.97/115VAC, PF 0.96/230VAC, PF 0.94/277VAC@full loadPF 0.97/115VAC, PF 0.96/230VAC, PF 0.94/277VAC@full loadPF 0.97/115VAC, PF 0.96/230VAC, PF 0.94/277VAC@full load
TOTAL HARMONIC DISTORTIONTHD< 20%(@load 60%/115VC,230VAC; @load 75%/277VAC)THD< 20%(@load 60%/115VC,230VAC; @load 75%/277VAC)THD< 20%(@load 60%/115VC,230VAC; @load 75%/277VAC)
EFFICIENCY (Typ.)90%90% 90.5%
AC CURRENT1.3A/ 115VAC 0.65A/ 230VAC 0.55A/ 277VAC1.3A/ 115VAC 0.65A/ 230VAC 0.55A/ 277VAC1.3A/ 115VAC 0.65A/ 230VAC 0.55A/ 277VAC
INRUSH CURRENT(Typ.)COLD START 60A(twidth=520 s measured at 50% Ipeak) at 230VAC μ ; Per NEMA410COLD START 60A(twidth=520 s measured at 50% Ipeak) at 230VAC μ ; Per NEMA410COLD START 60A(twidth=520 s measured at 50% Ipeak) at 230VAC μ ; Per NEMA410
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
4 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC4 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC4 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT<0.25mA/ 277VAC<0.25mA/ 277VAC<0.25mA/ 277VAC
NO LOAD POWER CONSUMPTION<0.15W <0.15W <0.15W