LED Power Solutions

powered by Current Automation

HLG-40H Series

40W Single Output Switching Power Supply

Application:

LED Lighting
LED Moving Sign

Features

* Universal AC input / Full range (up to 305VAC)
* Built-in active PFC function
* Protections: Short circuit / Over current / Over voltage / Over temperature
* Cooling by free air convection
* Output constant current level adjustable
* Class 2 power unit
* Three in one dimming function (1~10Vdc or PWM signal or resistance)
* Suitable for built in LED lighting system
* Suitable for dry / damp locations
* 100% full load burn-in test
* 3 years warranty

HLP-40H series

MODELHLP-40H-12 HLP-40H-15 HLP-40H-20
OUTPUTDC VOLTAGE12V15V20V
CONSTANT CURRENT REGION7.2 ~12V9 ~ 15V12 ~ 20V
RATED CURRENT3.33A 2.67A2A
RATED POWER40W40W40W
RIPPLE & NOISE (max.)150mVp-p 150mVp-p 150mVp-p
VOLTAGEADJ. RANGE10.8 ~ 13.5V13.5 ~ 17V17 ~ 22V
CURRENT ADJ. RANGE2 ~ 3.33A1.6 ~ 2.67A1.2 ~ 2A
VOLTAGE TOLERANCE±2.5%±2.0%±1.0%
LINE REGULATION±0.5%±0.5%±0.5%
LOAD REGULATION±2.0% ±1.5%±1.0%
SETUP, RISE TIME500ms, 80ms at full load 230VAC / 115VAC500ms, 80ms at full load 230VAC / 115VAC500ms, 80ms at full load 230VAC / 115VAC
HOLD UP TIME (Typ.)16ms/230VAC 16ms/115VAC at full load16ms/230VAC 16ms/115VAC at full load16ms/230VAC 16ms/115VAC at full load
INPUTVOLTAGE RANGE90 ~ 305VAC 127 ~ 431VDC90 ~ 305VAC 127 ~ 431VDC90 ~ 305VAC 127 ~ 431VDC
FREQUENCY RANGE47 ~ 63Hz47 ~ 63Hz47 ~ 63Hz
POWER FACTORPF>0.98/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full loadPF>0.98/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full loadPF>0.98/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load
TOTALHARMONIC DISTORTIONTHD< 20% when output loading>=60% at 115VAC/230VAC input and output loading>=75% at 277VAC inputTHD< 20% when output loading>=60% at 115VAC/230VAC input and output loading>=75% at 277VAC inputTHD< 20% when output loading>=60% at 115VAC/230VAC input and output loading>=75% at 277VAC input
EFFICIENCY (Typ.)87% 87% 88%
AC CURRENT0.43A/ 115VAC 0.24A/ 230VAC 0.23A/ 277VAC0.43A/ 115VAC 0.24A/ 230VAC 0.23A/ 277VAC0.43A/ 115VAC 0.24A/ 230VAC 0.23A/ 277VAC
INRUSH CURRENT(Typ.)COLD START 50A(twidth=210 s measured at 50% Ipeak) at 230VACCOLD START 50A(twidth=210 s measured at 50% Ipeak) at 230VACCOLD START 50A(twidth=210 s measured at 50% Ipeak) at 230VAC
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
12 units (circuit breaker of type B) / 20 units (circuit breaker of type C) at 230VAC12 units (circuit breaker of type B) / 20 units (circuit breaker of type C) at 230VAC12 units (circuit breaker of type B) / 20 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT<0.75mA/ 277VAC<0.75mA/ 277VAC<0.75mA/ 277VAC
Specs Sheet
untitled-3Download PDF
untitled-3Download PDF
untitled-3Download PDF

HLP-40H series

MODELHLP-40H-24HLP-40H-30HLP-40H-36
OUTPUTDC VOLTAGE24V30V36V
CONSTANT CURRENT REGION14.4 ~ 24V18 ~ 30V21.6 ~ 36V
RATED CURRENT1.67A 1.34A1.12A
RATED POWER40.1W 40.2W40.3W
RIPPLE & NOISE (max.)150mVp-p 200mVp-p200mVp-p
VOLTAGEADJ. RANGE22 ~ 27V27 ~ 33V33 ~ 40V
CURRENT ADJ. RANGE1 ~ 1.67A0.8 ~ 1.34A0.67 ~ 1.12A
VOLTAGE TOLERANCE±1.0%±1.0%±1.0%
LINE REGULATION±0.5%±0.5%±0.5%
LOAD REGULATION±0.5%±0.5%±0.5%
SETUP, RISE TIME500ms, 80ms at full load 230VAC / 115VAC500ms, 80ms at full load 230VAC / 115VAC500ms, 80ms at full load 230VAC / 115VAC
HOLD UP TIME (Typ.)16ms/230VAC 16ms/115VAC at full load16ms/230VAC 16ms/115VAC at full load16ms/230VAC 16ms/115VAC at full load
INPUTVOLTAGE RANGE90 ~ 305VAC 127 ~ 431VDC90 ~ 305VAC 127 ~ 431VDC90 ~ 305VAC 127 ~ 431VDC
FREQUENCY RANGE47 ~ 63Hz47 ~ 63Hz47 ~ 63Hz
POWER FACTORPF>0.98/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full loadPF>0.98/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full loadPF>0.98/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load
TOTALHARMONIC DISTORTIONTHD< 20% when output loading>=60% at 115VAC/230VAC input and output loading>=75% at 277VAC inputTHD< 20% when output loading>=60% at 115VAC/230VAC input and output loading>=75% at 277VAC inputTHD< 20% when output loading>=60% at 115VAC/230VAC input and output loading>=75% at 277VAC input
EFFICIENCY (Typ.)88%88.5%89%
AC CURRENT0.43A/ 115VAC 0.24A/ 230VAC 0.23A/ 277VAC0.43A/ 115VAC 0.24A/ 230VAC 0.23A/ 277VAC0.43A/ 115VAC 0.24A/ 230VAC 0.23A/ 277VAC
INRUSH CURRENT(Typ.)COLD START 50A(twidth=210 s measured at 50% Ipeak) at 230VACCOLD START 50A(twidth=210 s measured at 50% Ipeak) at 230VACCOLD START 50A(twidth=210 s measured at 50% Ipeak) at 230VAC
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
12 units (circuit breaker of type B) / 20 units (circuit breaker of type C) at 230VAC12 units (circuit breaker of type B) / 20 units (circuit breaker of type C) at 230VAC12 units (circuit breaker of type B) / 20 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT<0.75mA/ 277VAC<0.75mA/ 277VAC<0.75mA/ 277VAC
Specs Sheet
untitled-3Download PDF
untitled-3Download PDF
untitled-3Download PDF

HLP-40H series

MODEL HLP-40H-42 HLP-40H-48HLP-40H-54
OUTPUTDC VOLTAGE42V48V54V
CONSTANT CURRENT REGION25.2 ~ 42V28.8 ~ 48V32.4 ~ 54V
RATED CURRENT0.96A0.84A0.75A
RATED POWER40.3W 40.3W 40.5W
RIPPLE & NOISE (max.)300mVp-p300mVp-p300mVp-p
VOLTAGEADJ. RANGE40 ~ 46V44 ~ 53V 49 ~ 58V
CURRENT ADJ. RANGE0.58 ~ 0.96A0.5 ~ 0.84A0.45 ~ 0.75A
VOLTAGE TOLERANCE±1.0%±1.0%±1.0%
LINE REGULATION±0.5%±0.5%±0.5%
LOAD REGULATION±0.5%±0.5%±0.5%
SETUP, RISE TIME500ms, 80ms at full load 230VAC / 115VAC500ms, 80ms at full load 230VAC / 115VAC500ms, 80ms at full load 230VAC / 115VAC
HOLD UP TIME (Typ.)16ms/230VAC 16ms/115VAC at full load16ms/230VAC 16ms/115VAC at full load16ms/230VAC 16ms/115VAC at full load
INPUTVOLTAGE RANGE90 ~ 305VAC 127 ~ 431VDC90 ~ 305VAC 127 ~ 431VDC90 ~ 305VAC 127 ~ 431VDC
FREQUENCY RANGE47 ~ 63Hz47 ~ 63Hz47 ~ 63Hz
POWER FACTORPF>0.98/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full loadPF>0.98/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full loadPF>0.98/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load
TOTALHARMONIC DISTORTIONTHD< 20% when output loading>=60% at 115VAC/230VAC input and output loading>=75% at 277VAC inputTHD< 20% when output loading>=60% at 115VAC/230VAC input and output loading>=75% at 277VAC inputTHD< 20% when output loading>=60% at 115VAC/230VAC input and output loading>=75% at 277VAC input
EFFICIENCY (Typ.)89% 89.5%89.5%
AC CURRENT0.43A/ 115VAC 0.24A/ 230VAC 0.23A/ 277VAC0.43A/ 115VAC 0.24A/ 230VAC 0.23A/ 277VAC0.43A/ 115VAC 0.24A/ 230VAC 0.23A/ 277VAC
INRUSH CURRENT(Typ.)COLD START 50A(twidth=210 s measured at 50% Ipeak) at 230VACCOLD START 50A(twidth=210 s measured at 50% Ipeak) at 230VACCOLD START 50A(twidth=210 s measured at 50% Ipeak) at 230VAC
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
12 units (circuit breaker of type B) / 20 units (circuit breaker of type C) at 230VAC12 units (circuit breaker of type B) / 20 units (circuit breaker of type C) at 230VAC12 units (circuit breaker of type B) / 20 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT<0.75mA/ 277VAC<0.75mA/ 277VAC<0.75mA/ 277VAC